Page 2 highlights

System software: Navigator version Operating System Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: Default Boot Order M/S Certified Configuration distribution units (PDU's) are strongly recommended. L.18.03 or later Microsoft Windows NT Server 4.0, Enterprise Edition SP6a or later HP NetServer LT 6000r 700 MHz 2 - 6 4.06.26 PW or later Any size 128 MB minimum. Must be HP. 2 standard, 3 required for redundancy See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, Embedded A, Embedded B, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1 P2 - Client LAN P3 -Shared Storage (NetRAID-3Si) P4 - Local storage (NetRAID-1Si) Booted from embedded DAC Storage Local Controller Driver Cabinets (Physical drive location) Disk drives SCSI bus SCSI Ids May use embedded SCSI, embedded DAC, NetRAID-1Si, or NetRAID3Si. For embedded SCSI, use sym_hi.version 4.12 or later. For embedded DAC and NetRAID-xSi, use mraidnt.sys version 2.24. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SCSI Ids Channels HP NetRAID-3Si Adapter D5955A 1 W.01.30 B.02.02 Mraidnt.sys 2.24 A.01.15 or later 6, 7 0, 1, 2 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.18.03 or later
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition
Service pack
SP6a or later
SPU
Model
HP NetServer LT 6000r
Clock speed
700 MHz
No. of CPUs
2 - 6
BIOS version
4.06.26 PW or later
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
2 standard, 3 required for redundancy
Local storage
See
Local Storage
below.
I/O slots:
Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded A, Embedded B, PCI64-6, PCI64-5,
PCI64-4, PCI64-3, PCI64-2, PCI64-1
M/S Certified
Configuration
P2 - Client LAN
P3 –Shared Storage (NetRAID-3Si)
P4 – Local storage (NetRAID-1Si)
Booted from embedded DAC
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-1Si, or NetRAID-
3Si.
Driver
For embedded SCSI, use sym_hi.version 4.12 or later.
For embedded DAC
and NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives
Must be HP (hot swap or fixed)
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
Controller
Model
HP NetRAID-3Si Adapter D5955A
No. of controllers
1
Firmware
W.01.30
BIOS
B.02.02
Driver
Mraidnt.sys
2.24
NetRAID Assistant
A.01.15 or later
SCSI Ids
6, 7
Channels
0, 1, 2