HP LH4r HP Netserver LXr 8000 NetRAID-3Si Config Guide for Windows NT4.0 Clus - Page 3

HP 18.2 GB 7200 rpm Low Profile Ultra SCSI Disk Module D7174A

Page 3 highlights

Cabinet RAID arrays No. and mix of cabinets. Rack Storage/12: Model Status SCSI ID Disk SCSI Ids Disk drives: Cables Rack Storage/8 Model Status SCSI ID Disk SCSI Ids Disk drives: Cables A RAID array (logical disk) must be composed of all the same disk model (i.e., part number and suffix). Different size or speed disks are not allowed in the same RAID array. Any combination of disk models is allowed on a SCSI channel. Any combination of disk models is allowed in a cluster. RAID arrays may not span NetRAID Adapters. 1 - 3, any mix of Rack Storage 12s and Rack Storage/8s. D5989A plus 1 D6025A for each Rack Storage/12 (400/450 MHz) D5989B plus 1 D6205B for each Rack Storage/12 (400/450 MHz) D5989B plus 1 D6025B for each Rack Storage/12 (500/550 MHz) 5 (fixed) 0 - 4, 8 - 15 (fixed) HP 4.2 GB Ultra SCSI Disk Module D6104A HP 9.1 GB Ultra SCSI Disk Module D6106A HP 9.1 GB Ultra SCSI Disk Module D6107A HP 18.2 GB Ultra SCSI Disk Module D6108A HP 18.2 GB (10k rpm) Ultra SCSI Disk Module D7031A HP 18.2 GB (7200 rpm) Low Profile Ultra SCSI Disk Module D7174A HP 36.4 GB (10k rpm) Ultra SCSI Disk Module D8210A Any 2 HP LVD SCSI cables from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A D4902A 14, 15 (fixed) 0 - 3, 8 - 11 (fixed) HP 4.2 GB Ultra SCSI Disk Module D3583C HP 4.2 GB (10k rpm) Ultra SCSI Disk Module D4903A HP 9.1 GB Ultra SCSI Disk Module D4289A HP 9.1 GB (10k rpm) Ultra SCSI Disk Module D6019A HP 18.2 GB Ultra SCSI Disk Module D5039A NOTE All disks in a Rack Storage/8 must be the same speed. Cluster Adapter Cable D5957A (2 required per cabinet) NOTE If both channels 0 and 2 of the NetRAID Adapter are used, then cable D7131A must be used with Cluster Adapter D5957A on both channels. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

3
Cabinet
RAID arrays
A RAID array (logical disk) must be composed of all the same disk model
(i.e., part number and suffix).
Different size or speed disks are not
allowed in the same RAID array.
Any combination of disk models is
allowed on a SCSI channel.
Any combination of disk models is allowed
in a cluster.
RAID arrays may not span NetRAID Adapters.
No. and mix of
cabinets.
1 – 3, any mix of Rack Storage 12s and Rack Storage/8s.
Rack Storage/12
:
Model
D5989A plus 1 D6025A for each Rack Storage/12 (400/450 MHz)
D5989B plus 1 D6205B for each Rack Storage/12 (400/450 MHz)
D5989B plus 1 D6025B for each Rack Storage/12 (500/550 MHz)
Status SCSI ID
5 (fixed)
Disk SCSI Ids
0 – 4,
8 – 15 (fixed)
Disk drives:
HP 4.2 GB Ultra SCSI Disk Module D6104A
HP 9.1 GB Ultra SCSI Disk Module D6106A
HP 9.1 GB Ultra SCSI Disk Module D6107A
HP 18.2 GB Ultra SCSI Disk Module D6108A
HP 18.2 GB (10k rpm) Ultra SCSI Disk Module D7031A
HP 18.2 GB (7200 rpm) Low Profile Ultra SCSI Disk Module D7174A
HP 36.4 GB (10k rpm) Ultra SCSI Disk Module D8210A
Cables
Any 2 HP LVD SCSI cables from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
Rack Storage/8
Model
D4902A
Status SCSI ID
14, 15 (fixed)
Disk SCSI Ids
0 – 3,
8 – 11 (fixed)
Disk drives:
HP 4.2 GB Ultra SCSI Disk Module D3583C
HP 4.2 GB (10k rpm) Ultra SCSI Disk Module D4903A
HP 9.1 GB Ultra SCSI Disk Module D4289A
HP 9.1 GB (10k rpm) Ultra SCSI Disk Module D6019A
HP 18.2
GB Ultra SCSI Disk Module D5039A
NOTE
All disks in a Rack Storage/8 must be the same speed.
Cables
Cluster Adapter Cable D5957A (2 required per cabinet)
NOTE
If both channels 0 and 2 of the NetRAID Adapter are used, then
cable D7131A must be used with Cluster Adapter D5957A on both
channels.