HP LH4r HP Netserver LXr 8000 RS12/FC Config Guide for Windows NT4.0 Clusters - Page 2

Storage

Page 2 highlights

SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: HP NetServer LXr 8000 400/450, 500/550 MHz 2 - 4 Rel 10 or later Any size 256 MB minimum. Must be HP. 3 See Local Storage below. P8 - P7 Host Bus Adapter P8 - P2 Client LAN P7 - P1 Intra-cluster (Heartbeat) LANs P2 - Remote card (optional) Storage NOTE The Client LAN must be installed in a higher PCI slot than the Intra-cluster LAN. Local Controller Driver Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May Use - Embedded SCSI, NetRAID-1Si or NetRAID-3Si in PCI slot P1, otherwise any controller listed on the HP Tested Products List. May Not Use - NetRAID-1 or NetRAID-3 2.24 SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver SPU I/O slot RAID level Cabinet RAID arrays No. of cabinets FC Array Cards Model No. of cards/cabinet (Required) HP D8602A 1 1.12 or later P8 or P7 0, 1, 3, 5, or 0 & 1 Not more than 8 physical drives per logical array and not more than 8 LUNs are permitted per Rack Storage/12FC and Rack Storage/12 combination in a cluster. 1 D5990A 1 - Simplex (Supplied with Rack Storage/12FC.) 2 - Duplex (Additional card required in the Rack Storage/12FC.) 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

2
SPU
Model
HP NetServer LXr 8000
Clock speed
400/450, 500/550 MHz
No. of CPUs
2 – 4
BIOS version
Rel 10 or later
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
3
Local storage
See
Local Storage
below.
I/O slots:
P8 – P7 Host Bus Adapter
P8 – P2
Client LAN
P7 – P1 Intra-cluster (Heartbeat)
LANs
P2 – Remote card (optional)
NOTE
The Client LAN must be installed in a higher PCI slot than the
Intra-cluster LAN.
Storage
Local
Controller
May Use
- Embedded SCSI, NetRAID-1Si or NetRAID-3Si in PCI slot
P1, otherwise any controller listed on the HP Tested Products List.
May Not Use
- NetRAID-1 or NetRAID-3
Driver
2.24
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
(Required)
Host Bus Adapter
Model
HP D8602A
No. of HBAs
1
Driver
1.12 or later
SPU I/O slot
P8 or P7
RAID level
0, 1, 3, 5, or 0 & 1
Cabinet
RAID arrays
Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets
1
FC Array Cards
Model
D5990A
No. of cards/cabinet
1 - Simplex (Supplied with Rack Storage/12FC.)
2 - Duplex (Additional card required in the Rack Storage/12FC.)