SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: HP NetServer LXr 8500 550 MHz 2 - 8 ASPN Release 5 Any size 256 MB minimum. Must be HP. 3 See Local Storage below. P6 - Shared storage controller P4 - Client LAN P3 - Intra-cluster (Heartbeat) LAN All others - Any other plug-in cards. Storage Local Physical drive location Disk drives Controller SCSI bus Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SPU I/O slot SCSI ID Channels RAID level Logical disks Configuration options: SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP May use embedded SCSI or NetRAID-3Si in PCI slot P1 otherwise any controller listed on the HP Tested Products List. May not use NetRAID-1, NetRAID-3, or NetRAID-1Si. Any HP cables that meet SCSI specifications and any SCSI bus speed HP NetRAID 3si Adapter D5955A 1 W.01.20 or later B.01.10 or later 2.22 or later A.01.15 or later P6 6, 7 0, 1, 2 1, 5, 10, 50 1 per RAID array Cluster mode on Cache write-policy to write-thru Set any other options as you prefer 2