HP LH4r HP Netserver LXr 8500 Rack Storage/12FC Config Guide for Windows NT4.
HP LH4r - NetServer - 256 MB RAM Manual
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP LH4r manual content summary:
- HP LH4r | HP Netserver LXr 8500 Rack Storage/12FC Config Guide for Windows NT4. - Page 1
that Hewlett-Packard supports for using the HP NetServer LXr 8500 with the HP Rack Storage/12FC and Microsoft Cluster Server These configurations minimize single points of failure (SPOF) and provide extended availability. The specific configuration certified and supported by both Hewlett - HP LH4r | HP Netserver LXr 8500 Rack Storage/12FC Config Guide for Windows NT4. - Page 2
NT Server 4.0, Enterprise Edition with Service Pack SP6a or later. HP NetServer LXr 8500 400/450, 500/550, NetRAID-xSi, use mraidnt.sys version 2.24. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP Any HP cables that meet SCSI specifications - HP LH4r | HP Netserver LXr 8500 Rack Storage/12FC Config Guide for Windows NT4. - Page 3
(Shared Storage to Hub and Server to Hub ): 3 meter D6978A 5 meter D6979A 10 meter D7080A Required HP D6976A 6-port fibre channel 1 HP Rack Storage/12 Number of cabinets: Model Status SCSI ID Disk SCSI IDs Disk drives: Cables LANs LAN connection Optional 1 - 2 HP NetServer Rack Storage/12 - D5989B - HP LH4r | HP Netserver LXr 8500 Rack Storage/12FC Config Guide for Windows NT4. - Page 4
supported driver NOTE If the Client and Intracluster LANs are the same model the Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LXr 8500, one HP - HP LH4r | HP Netserver LXr 8500 Rack Storage/12FC Config Guide for Windows NT4. - Page 5
LAN in P4 Client LAN in P3 HP TopTools Control card in P2 (optional) 2. The two bottom shared storage devices are HP Rack Storage/12 SCSI cabinets. Optional shared storage devices. LEGEND Solid (blue) lines are fibre channel Optical or Copper cables. See inside this guide for specifications - HP LH4r | HP Netserver LXr 8500 Rack Storage/12FC Config Guide for Windows NT4. - Page 6
Power Cabling to Separate Power Circuits 6 - HP LH4r | HP Netserver LXr 8500 Rack Storage/12FC Config Guide for Windows NT4. - Page 7
Versions 17 October 2000 1 December 1999 Added 700 MHz model. Revised intro, boot spec and I/O slots. Added boot priority and Ultra3 drives. Removed simplex option. Corrected verbiage in drawing Initial release 7
1
HP NetServer LXr 8500
with
HP Rack Storage/12FC & HP Rack Storage/12
Cluster Configuration Guide
17 October 2000
(see
Versions
at the end of this document)
Introduction
This document defines the configurations that Hewlett-Packard supports for using the HP NetServer LXr 8500
with the HP Rack Storage/12FC and Microsoft Cluster Server These configurations minimize single points of
failure (SPOF) and provide extended availability.
The specific configuration certified and supported by both
Hewlett-Packard and Microsoft is defined, as are other guidelines to assist you in configuring your clustered
NetServers.
This guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these
configurations can result in an inoperative cluster or an operating cluster with degraded performance, hidden
SPOFs, etc., and therefore will not be supported by HP.
What's Defined in a Racked Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LXr 8500
Each node must be the same model SPU, but may have different clock
speeds, main memory sizes, cache sizes, and number of CPUs.
Number of nodes
2
Shared Storage
HP Rack Storage/12FC with FCArray Cards, HP disks, and a HP D8602A
HBA in each server.
See
Shared Storage
below.
LANs:
Client LAN
Any that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
HP D5013A/B with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.16.05 or later