Operating System SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack SP6a or later. HP NetServer LXr 8500 400/450, 500/550, 700 MHz 2 - 8 ASPN Release 8 Any size 128 MB minimum. Must be HP. 3 required for redundancy See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, PCI-1, PCI-2, SCSI A, SCSI B, PCI-3, PCI-4, PCI-5 through PCI-10 P6 - Shared Storage HBA P4 - Intra-cluster (Heartbeat) LAN P3 - Client LAN P2 - HP TopTools Control card D6028A (optional) Booted from embedded SCSI Local Controller Driver Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver RAID level Cabinet Model RAID arrays No. of cabinets FC Array Cards May use embedded SCSI, NetRAID-1Si or NetRAID-3Si. For embedded SCSI, use sym_hi.sys version 4.12 or later. For NetRAID-xSi, use mraidnt.sys version 2.24. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Required - D5991A HP Fibre Channel Host Bus Adapter - HP D8602A 1 Hhba5100.sys 1.12 or later 0, 1, 3, 5, 10 HP NetServer Rack Storage/12FC- D5991A Not more than 8 physical drives per logical array and not more than 8 LUNs are permitted per Rack Storage/12FC and Rack Storage/12 combination in a cluster. 1 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack
SP6a or later.
SPU
Model
HP NetServer LXr 8500
Clock speed
400/450, 500/550, 700 MHz
No. of CPUs
2 – 8
BIOS version
ASPN Release 8
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
3 required for redundancy
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, PCI-1, PCI-2, SCSI A, SCSI B, PCI-3, PCI-4, PCI-5
through PCI-10
M/S Certified
Configuration
P6 – Shared Storage HBA
P4 – Intra-cluster (Heartbeat)
LAN
P3 – Client LAN
P2 – HP TopTools Control card D6028A (optional)
Booted from embedded SCSI
Storage
Local
Controller
May use embedded SCSI, NetRAID-1Si or NetRAID-3Si.
Driver
For embedded SCSI, use sym_hi.sys version 4.12 or later.
For NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
Required
– D5991A
Host Bus Adapter
Model
HP Fibre Channel Host Bus Adapter - HP D8602A
No. of HBAs
1
Driver
Hhba5100.sys 1.12 or later
RAID level
0, 1, 3, 5, 10
Cabinet
Model
HP NetServer Rack Storage/12FC- D5991A
RAID arrays
Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets
1
FC Array Cards