HP LH4r HP Netserver LXr 8500 Rack Storage/12FC Installation Guide - Page 6

Storage

Page 6 highlights

SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: Storage HP NetServer LXr 8500 400/450, 500/550 MHz 2 - 8 Rel 5 or later Any size 256 MB minimum. Must be HP. 3 See Local Storage below. P6 - Host Bus Adapter P4 - Intra-cluster (Heartbeat) LANs P3 - Client LAN P2 - HP TopTools Control card D6028A (optional) Local Controller Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May Use - Embedded SCSI, NetRAID-1Si or NetRAID-3Si in PCI slot P1, otherwise any controller listed on the HP Tested Products List. May Not Use - NetRAID-1 or NetRAID-3 SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver SPU I/O slot RAID level Cabinet Model RAID arrays No. of cabinets FC Array Cards Model No. of cards/cabinet Firmware Status SCSI ID Disk SCSI IDs (Required) HP D8602A 1 1.12 or later P6 0, 1, 3, 5, or 0 & 1 D5991A Not more than 8 physical drives per logical array and not more than 8 LUNs are permitted per Rack Storage/12FC and Rack Storage/12 combination in a cluster. 1 D5990A 1 - Simplex (Supplied with Rack Storage/12FC.) 2 - Duplex (Additional card required in the Rack Storage/12FC.) 4.64-00 or later 5 (fixed) 0 - 3, 8 - 15 (fixed) 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

2
SPU
Model
HP NetServer LXr 8500
Clock speed
400/450, 500/550 MHz
No. of CPUs
2 – 8
BIOS version
Rel 5 or later
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
3
Local storage
See
Local Storage
below.
I/O slots:
P6 – Host Bus Adapter
P4 – Intra-cluster (Heartbeat)
LANs
P3 – Client LAN
P2 – HP TopTools Control card D6028A (optional)
Storage
Local
Controller
May Use
- Embedded SCSI, NetRAID-1Si or NetRAID-3Si in PCI slot
P1, otherwise any controller listed on the HP Tested Products List.
May Not Use
- NetRAID-1 or NetRAID-3
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
(Required)
Host Bus Adapter
Model
HP D8602A
No. of HBAs
1
Driver
1.12 or later
SPU I/O slot
P6
RAID level
0, 1, 3, 5, or 0 & 1
Cabinet
Model
D5991A
RAID arrays
Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets
1
FC Array Cards
Model
D5990A
No. of cards/cabinet
1 - Simplex (Supplied with Rack Storage/12FC.)
2 - Duplex (Additional card required in the Rack Storage/12FC.)
Firmware
4.64-00 or later
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0 – 3,
8 – 15 (fixed)