HP LH4r HP Netserver LXr Pro8 Technical Reference Label 2 - Page 1
HP LH4r - NetServer - 256 MB RAM Manual
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
NetServer LXr Pro8 Outside Service Reference Label About This Label Audience Assumptions This Service Reference Label is for trained service personnel. Hewlett-Packard Company assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. Electrostatic Discharge To avoid catastrophic or hidden damage to components, wear a wrist strap and use a static-dissipative work surface connected to the chassis when handling components. Use an antistatic service kit, such as 3M® 8501/8502/8505 or equivalent. This information is subject to change without notice and is provided without warranty. Copyright 1998, Hewlett-Packard Company. All rights reserved. Support HP NetServer Navigator CD: CD is shipped with the system in the Navigator Kit. The Information Assistant on the CD contains complete documentation and will search, display, and print on a NetServer system or any Windows® PC. A copy of this label can be printed from the Information Assistant on a current Navigator CD. (To maintain safety compliance, do not keep any paper inside the system cabinet.) Subscriptions are available. See the Information Assistant or one of the Electronic Support Services, below, for ordering. HP NetServer Diagnostic Assistant: Run from Navigator CD, or Use flexible disk shipped with system in pouch in the satellite, or Download from one of the Electronic Support Services, below. Proactive E-Mail Notification: Sign up at http://www.hp.com/go/netserver. Click on "Service and Support" Electronic Support Services: Internet Web Page http://www.hp.com/go/netserver Internet FTP ftp://ftp.hp.com/pub/servers CompuServe Library GO HPPC Support Questions: HP-Authorized Reseller CompuServe Discussion Forum GO HPPC US / Canada Phone Support 1-970-635-1000 (Colorado) Europe Phone Support (+31-20) 581-3330 (Netherlands) HP has offices in over 100 countries. Check telephone directory. Satellite Disassembly / Reassembly x4 5 4 Specifications Power Requirements Voltage and frequency: 200-240VAC 16A single cord input at 47-63Hz Power consumption: 970W typical usage max; 1560W design max Maximum inrush current: 80A for 10ms Power availability: 200W continuous to PCI cards and internal drives Circuits: Delayed action circuit breaker recommended. Configurations use one or two branch circuits per rack. • North America 208/240V 60Hz -- NEMA AB1 class 14B 20A for each 16A PDU. 20 Amp branch circuits are recommended, using NEMA L6-20R receptacles. • Outside North America 220 / 230 / 240V 50/60Hz -- IEC Type D for 16A circuits for each 16A PDU. Minimum 16 Amp branch circuits are recommended. Space Requirements System dims: 17.5"H x 19.0"W x 32.1"D (44.5cm x 48.6cm x 81.5cm) Rack space: 10 EIA units Rack clearance: 46" (117cm) beyond rear of HP rack -- door mounted 30" (76cm) beyond rear of HP rack -- no door System weight: 170lb (76kg) Air Conditioning Requirements Maximum heat output: 3300 BTU/ hour Operating temperature: 41 to 95 degrees F (5 to 35 degrees C) Operating humidity: 20% to 80% RH noncondensing Tested PCI Cards Limitations apply to the use of PCI cards in this system. Refer to the Configuration Advisor on HP NetServer Navigator CD. Control Panel Troubleshooting Check that the Satellite Retention Bracket is in place on the center rear of the base chassis. Run Indicator Green during power up = Power On Self-Test has passed; system is starting to boot Green during operation = BIOS is running DC Ouput Indicator Green = DC voltages from power supplies OK Off = System in standby -- press power button. Check CPU Power Switch on rear of Docking Station AC Input Indicator Green = AC power input to system OK Off = Check AC power to system Attention Indicator Off = Normal operation Yellow = Component failure -- refer to message display on Control Panel Flashing Yellow = Hardware Identification and Labeling Utility is flashing the light to identify this server Notes: Message display on control panel will display fatal errors for one minute before system shuts down. 4-pin connector on rear of Control Panel Board is unused. Data Integrity and System Reliability The covers and panels are integral parts of the system and must be in place to maintain data integrity under normal levels of electromagnetic noise, static discharge, and vibration. Even at low room temperatures, all covers and panels must be in place to provide controlled airflow for system reliability. Check that each Mass Storage Shelf has either a drive or a filler panel -- whether or not the front door is in place. Check that the rear panel, two fan packs, and the top cover are in place -- whether the system is rack-mounted or being shipped. Shipping the System All covers and panels must be in place when the system is moved or shipped. The shipping package protects the system -- including properly installed mass storage devices -- under normal shipping conditions. Do not ship the system mounted in a rack. Power Supply Modules Troubleshooting Check the Satellite Power Interlock Switch on the left rear of the base chassis. DC Output Indicator Green = DC output voltages from module OK Off = Check CPU Power Switch on rear of Docking Station AC Input Indicator Green = AC power input to module OK Attention Indicator Off = Normal operation Yellow = System is in standby mode or one or more DC output voltages is out of specification Notes: Connector on front of each Power Supply Module is unused. 6 4 3 Memory Troubleshooting Reserved Check that DIMMs are the correct HP product number. (See panel 8 of this label.) DIMMs supplied and warranted by HP have an HP label. Repairs due to the use of non-HP DIMMs are not covered 31 0 under the warranty. Size DIMMs Inter- Memory DIMM Locations leave Board 28 24 20 16 12 8 4 0 256MB 2 4 Upper 512MB 4 8 Upper 1GB 8 16 Upper 1.5GB 12 8 Upper 2GB 16 16 Upper 3GB 24 16 Upper 4GB 32 16 Upper Size DIMMs Inter- Memory leave Board 28 24 20 16 12 8 4 0 5GB 40 16 Upper Lower * 6GB 48 16 Upper Lower * 7GB 56 16 Upper Lower * 8GB 64 16 Upper Lower * * Refers to Optional Lower Memory Board 002-52459, Label Version 2 Product and Part Numbers For a list of all accessories, use the Information Assistant on a current Navigator CD or download the HP NetServer Order Assistant from www.hp.com/go/netserver. For rack configuration and installation information, download the HP NetServer Rack Assistant. Internal Accessories D5030A Processor Board, Dual 200 / 1MB (incl. CPUs) D5026A 256MB Memory DIMM Kit (2 ea. 128MB DIMMs) D5027A Second Memory Board (32 DIMM sockets) D5963A Non-DAC Ultra SCSI Extender Drawer, 6-Channel D5972A DAC Cable Extender, 6-Cable D5973A Hot-Swap Kit -- Power Supply and Fan Packs Internal Mass Storage D4910A D4911A C1555A 4GB wide SCSI HDD with drive mounting tray 9GB wide SCSI HDD with drive mounting tray DAT Tape, HP Model 24i (order D2199A tray) Mounting Trays D2199A 5 1/2" DAT / CD Tray (3-pack; no front panel) D2198B 3 1/2" Non Hot-Swap Drive Tray (3-pack; incl. front panel) I/O Cards D4943A NP NetRaid PCI DAC Card D4983B D5013A J2585B Cable Kit for 3rd connector of D4943A DAC HP DeskDirect 10/100TX PCI Server LAN Adapter HP DeskDirect 10/100VG PCI LAN Adapter External Mass Storage D3636C D3637C D4902A D3583C D4903A D4289A D5039A SCSI Cable; Std. HD-68 to Std. HD-68, 2.5m SCSI Cable; Std. HD-68 to Ultra HD-68, 2.5m Rack Storage/8 Storage Enclosure 4.2GB Hot-Swap Ultra SCSI Disk Module 4.2GB 10,000rpm Hot-Swap Ultra SCSI Disk Module 9.1GB Hot-Swap Ultra SCSI Disk Module 18.2GB Hot-Swap Ultra SCSI Disk Module Uninterruptable Power Supplies (order from APC Corp.) NS3000RMT3U 208V UPS U.S. In: L6-20P, Out: 2 L6-20R and 1 L6-30R NS3000RMI3U 230V UPS Europe In: C20, Out: 1 C19, 8 C13 Power Distribution Units (no power cord) E7670A E7671A E7672A E7666A 10A PDU, 19"; In: C14, Out: 10 C13 16A PDU, 19"; In: C20, Out: 6 C13 and 2 C19 Kit: E7670A and E7671A PDUs plus E7742A Jumper Cord 16A Dual-Input PDU, 56"; In: 2 C20, Out: 2 C19 and 12 C13 Power Cords E7798A Power Cord, 250 VAC (C20 to C19), 2.5m (std. with system) E7804A Power Cord, 250 VAC (C20 to C19), 4.0m E7801A Power Cord, 240 VAC (L6-20P to C19), 2.5m E7803A Power Cord, 250 VAC (L6-20P to C19), 4.5m E7799A Power Cord, 240 VAC (L6-30P to C19), 2.5m E7805A Power Cord, 240 VAC (L6-30P to C19), 4.5m E7800A Power Cord, 240 VAC (Unterminated to C19), 2.5m E7806A Power Cord, 240 VAC (Unterminated to C19), 4.5m D4991A Y Adapter Power Cord (C14 to 2 C13) (for 2 RS/8s in one rack) E7742A Jumper Power Cord, 2.5m (C14 to C13) Rack Accessories (Download HP NetServer Rack Assistant Software for details. See Panel on this label.) D4984A Rack Installation Kit with Extra Hardware and Install Docs E7797A Rack Mounting Hardware Kit (25 ea. 10-32 screws and nuts) E7723A Cable Guide, 24", pkg. of 2 D4984-60007 Cable Ties, Hook-and-Loop, 12", pkg. of 5 D4950B HP NetServer Keyboard, Mini-DIN C3751B HP Mouse, Mini-DIN J1493A Console Switch 4 port J1497A Console Switch 8 port J1462A Switch / Server Cables, 7 ft, set of 3 for one server J1463A Switch / Server Cables, 12 ft, set of 3 for one server 002-52459, Rev B