Fixes originally released as patches - virtual san
View all HP LeftHand P4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
• 11131 - Managed snapshots of a SQL volume set may cause errors. Affects SQL Server® 2005 pre SP3. SP3 or Microsoft Hot Fix KB934396 fixes this issue. • 11361 - Fixed issue with the Cliq assignvolume command where lack of initiator name caused an error even though it is an optional parameter. • 10391 - Fixed interaction between installed CLI and SAN/iQ software whereby repeated use of a few specific commands could cause unexpected memory usage. • 10396 - Fix included to assure network card settings on the NSM 160 are consistently showing that TCP Segmentation Offload is turned off to prevent network communication problems in some environments. • 10398 - Fixed a rare problem in the storage server that caused it to spontaneously restart under a combination of heavy IO load and snapshot deletes. • 10409 - Changed the display for the iSCSI gateway connection to Hostname(IP Address) instead of just the IP address for ease of use. • 10410 - Fixed the incorrect reporting of CPU Utilization in alert notification and performance dashboard. • 10415 - Added upgrade logic to attempt repair of OS array when possible during upgrade rather than failing when encountering this rare condition. • 10417 - Added a check for verifying IP address format of the Virtual IP in the CLIQ command modifyCluster. • 10418 - Added additional checking for a few specific CLI commands when executed from the on-node CLI. • 10537 - Made the System Watch monitoring variable a permanent variable to assure it is not accidentally deleted. • 10544 - Added RAID controller cache status to the CMC hardware report. • 10563 - Added a Node Summary report to the Centralized Management Console tasks menu to provide an efficient way to gather basic storage node information from multiple nodes. • 10576 - Field imaging now can be performed with the SATA-DVD drive on the NSM 2060. • 10606 - Fixed issue that blocked upgrades and back-outs if the OS hardware RAID array is degraded or rebuilding. • Fixed issue where the Failover Manager and ESX Failover Manger were sharing install IDs which could cause some confusion. Fixes originally released as patches • 9928 - The background parity initialization status has been corrected for RAID 5 and RAID 6 Logical Drives. • 10354 - Insight Manager agents are now compatible with 5.2x firmware. • 10355 - Storage nodes upgraded to SAN/iQ 8.0 that use CHAP authentication, now have sessions displayed in the SAN/iQ 8.0 Performance Monitor. • 10394 - Eliminated interruption of logging services and addressed a service connection issue that can lead to a short term volume availability outage. • 10518 - For the NSM2060/NSM4150 storage nodes, compress the RAID controller log to reduce space utilization issues of the log partition. • 10534 - Fixed issue where a disconnect from the CMC occurred when the Service Console is trying to upload large log files. • 10553 - An upgrade process does not complete properly, which can result in SAN/iQ services not restarting as expected. • 10633 - Prevent the SAN/iQ store service from consuming excess memory in certain situations involving large volumes/snapshots. SAN/iQ software release notes 7