HP NetServer LH 6000 HP Netserver LPr NetRAID-3Si Config Guide for Windows 20 - Page 2
Storage
View all HP NetServer LH 6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
System software: Navigator version Operating System SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM Local storage I/O slots: Default Boot Order M/S Certified Configuration Storage L.18.03 or later Microsoft Windows 2000 Advanced Server HP NetServer LPr 850 MHz. 2 4.06.33 PR or later Any size 256 MB minimum. Must be HP. See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4 P1 - Local storage - NetRAID-1Si P2 - Client LAN P3 - Shared storage - NetRAID-3Si P4 -- Intra-cluster (Heartbeat) LAN Booted from NetRAID-1Si Local Controller Driver Cabinets (physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI IDs May use embedded SCSI, NetRAID-1Si, or NetRAID-3Si. For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD or later. For NetRAID-xSi, use mraid35x.sys version 2.62 (Navigator L.18.04.5 or later). SPU internal drive bays or HP external drive cabinet (e.g.,HP Rack Storage/12), any number. HP only Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SCSI ID Channels RAID level Logical disks HP NetRAID-3Si Adapter D5955A 1 W.01.30 B.02.02 Mraid35x.sys 2.62 A.01.15 or later 6, 7 0, 1, 2 1, 5, 10, 50 1 per RAID array 8 maximum per NetRAID adapter 2