HP NetServer LXr Pro8 HP Netserver LH 6000 NetRAID-3Si Config Guide for Windo - Page 2

Storage

Page 2 highlights

Operating System SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack SP6A or later HP NetServer LH6000 550, 700 MHz 2 - 6 4.06.21 PU or later (550 MHz) 4.06.26 PU or later (700 MHz) Any size 256 MB minimum. Must be HP. See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI64-8, PCI64-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1 P1 - Client LAN P5 - Free or Local Storage P6 - Shared Storage Controller Booted from embedded SCSI Local Controller Driver Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May use embedded SCSI, embedded DAC, NetRAID-1Si, or NetRAID3Si. For embedded SCSI, use sym_hi.version 4.12 or later. For embedded DAC and NetRAID-xSi, use mraidnt.sys version 2.24. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP. Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SCSI ID Channels RAID level Logical disks Configuration options: HP NetRAID-3Si Adapter D5955A 1 W.01.30 B.02.02 Mraidnt.sys 2.24 A.01.15 or later 6, 7 0, 1, 2 1, 5, 10, 50 1 per RAID array, 8 maximum per NetRAID-3Si adapter Cluster mode on Cache write-policy to write-thru Set any other options as you prefer 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

2
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack
SP6A or later
SPU
Model
HP NetServer LH6000
Clock speed
550, 700 MHz
No. of CPUs
2 – 6
BIOS version
4.06.21 PU or later (550 MHz)
4.06.26 PU or later (700 MHz)
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI64-8,
PCI64-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
M/S Certified
Configuration
P1 - Client LAN
P5 – Free or Local Storage
P6 - Shared Storage Controller
Booted from embedded SCSI
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-1Si, or NetRAID-
3Si.
Driver
For embedded SCSI, use sym_hi.version 4.12 or later.
For embedded
DAC and NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
Controller
Model
HP NetRAID-3Si Adapter D5955A
No. of controllers
1
Firmware
W.01.30
BIOS
B.02.02
Driver
Mraidnt.sys 2.24
NetRAID Assistant
A.01.15 or later
SCSI ID
6, 7
Channels
0, 1, 2
RAID level
1, 5, 10, 50
Logical disks
1 per RAID array, 8 maximum per NetRAID-3Si adapter
Configuration
options:
Cluster mode on
Cache write-policy to write-thru