HP NetServer LXr Pro8 HP Netserver LH 4 Surestore E Config Guide for Windows - Page 2

Storage

Page 2 highlights

Navigator version Operating System Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: Storage L.15.00 or later Microsoft Windows NT Server 4.0, Enterprise Edition SP4 or later HP NetServer LH 4 400 or 450 MHz. 2 - 4 4.06.12 PS Any size 256 MB minimum. Must be HP. 3 or 4 Internal or external. See Local Storage below. P6, P7, P8 - Shared storage controller P2 - Intra-cluster (Heartbeat) LAN P1 - Client LAN P3-P5 - Local storage controller or any other plug-in cards. Local Controller Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI IDs Use embedded RAID, otherwise any manufacturer or driver in any available I/O slot. SPU internal drive Must be HP. Any Shared Host Bus Adapter Model No. of HBAs Driver SPU I/O slot SCSI ID Disk Array Controller Model No. of controllers Firmware RAID level (internal) Logical disks Hot spare SCSI ID Disk Array Storage Model HP A5252B Wide Differential SCSI Adapter. 1 - 3 per NetServer. "Adaptec AHA-294X/AHA-394X/AIC-78XX SCSI Controller" driver in NT 4.0 SP4 or later P8 (1st HBA), P7 (2nd HBA), P6 (3rd HBA) 7 HP A3706A Model 12H 96MB Controller with SureStore E 12H 2 per SureStore E 12H HP54 or later. 1/0 and 5 Logical units within each array must be numbered from 0 - 7. Active Hot Spare. 0 - 6, or 8 - 15 HP A3700AB SureStore E 12H Disk Array 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

2
Navigator version
L.15.00 or later
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition
Service pack
SP4 or later
SPU
Model
HP NetServer LH 4
Clock speed
400 or 450 MHz.
No. of CPUs
2 - 4
BIOS version
4.06.12 PS
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
3 or 4
Local storage
Internal or external.
See
Local Storage
below.
I/O slots:
P6, P7, P8 - Shared storage controller
P2 – Intra-cluster (Heartbeat) LAN
P1 – Client LAN
P3-P5 - Local storage controller or any other plug-in cards.
Storage
Local
Controller
Use embedded RAID, otherwise any manufacturer or driver in any
available I/O slot.
Cabinets (Physical drive
location)
SPU internal drive
Disk drives (hot swap
or fixed)
Must be HP.
SCSI IDs
Any
Shared
Host Bus Adapter
Model
HP A5252B Wide Differential SCSI Adapter.
No. of HBAs
1 – 3 per NetServer.
Driver
“Adaptec AHA-294X/AHA-394X/AIC-78XX SCSI Controller”
driver in NT 4.0 SP4 or later
SPU I/O slot
P8 (1
st
HBA), P7 (2
nd
HBA), P6 (3
rd
HBA)
SCSI ID
7
Disk Array Controller
Model
HP A3706A Model 12H 96MB Controller with SureStore E 12H
No. of controllers
2 per SureStore E 12H
Firmware
HP54 or later.
RAID level (internal)
1/0 and 5
Logical disks
Logical units within each array must be numbered from 0 – 7.
Hot spare
Active Hot Spare.
SCSI ID
0 – 6, or 8 – 15
Disk Array Storage
Model
HP A3700AB SureStore E 12H Disk Array