HP NetServer LXr Pro8 HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide - Page 3

HP 18.2 GB 10k rpm Low Profile Ultra SCSI Disk Module D7175A

Page 3 highlights

Model No. of cards/cabinet Firmware Status SCSI ID Disk SCSI IDs Disk drives: Fibre-channel cables D5990A 2 - (Requires second card be installed in the Rack Storage/12FC.) 4.64-00 or later 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure including: HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D6107A HP 9.1 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1168A HP 18.2 GB (7200 rpm) Half Height Ultra2 SCSI Disk Module D6108A HP 18.2 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1216A HP 18.2 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D7031A HP 18.2 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1166A HP 18.2 GB (7200 rpm) Low Profile Ultra SCSI Disk Module D7174A HP 18.2 GB (10k rpm) Low Profile Ultra SCSI Disk Module D7175A HP 36.4 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D8210A HP 36.4 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module D9419A Optical (Server to Hub only): 50 meter D6980A 100 meter D6981A Copper (Shared Storage to Hub and Server to Hub ): 3 meter D6978A 5 meter D6979A 10 meter D7080A Hub Model Quantity Required HP D6976A 6-port fibre channel 1 HP Rack Storage/12 Number of cabinets: Status SCSI ID Disk SCSI IDs Disk drives: Cables Optional 1 - 2 5 (fixed) 0 - 3, 8 - 15 (fixed) Same as HP Rack Storage/12FC Any HP LVD SCSI cables from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A LANs LAN connection Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or any equivalent The intra-cluster LAN may only be used for cluster node communication via a crossover cable. It may not be used for client communication. Client LAN Any LAN 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

3
Model
D5990A
No. of cards/cabinet
2 -
(Requires second card be installed in the Rack Storage/12FC.)
Firmware
4.64-00 or later
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0 – 3,
8 – 15 (fixed)
Disk drives:
Any HP drive supported by storage enclosure including:
HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A
HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A
HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D6107A
HP 9.1 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1168A
HP 18.2 GB (7200 rpm) Half Height Ultra2 SCSI Disk Module D6108A
HP 18.2 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1216A
HP 18.2 GB (10k rpm) Half
Height Ultra2 SCSI Disk Module D7031A
HP 18.2 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1166A
HP 18.2 GB (7200 rpm) Low Profile Ultra SCSI Disk Module D7174A
HP 18.2 GB (10k rpm) Low Profile Ultra SCSI Disk Module D7175A
HP 36.4 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D8210A
HP 36.4 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module D9419A
Fibre-channel cables
Optical (Server to Hub only):
50 meter D6980A
100 meter D6981A
Copper (Shared Storage to Hub and Server to Hub ):
3 meter D6978A
5 meter D6979A
10 meter D7080A
Hub
Required
Model
HP D6976A 6-port fibre channel
Quantity
1
HP Rack Storage/12
Optional
Number of cabinets:
1 – 2
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0 – 3,
8 – 15 (fixed)
Disk drives:
Same as HP Rack Storage/12FC
Cables
Any HP LVD SCSI cables from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or any
equivalent
Any LAN
The intra-cluster LAN may only be
used for cluster node communication
via a crossover cable.
It may not be
used for client communication.