HP NetServer LXr Pro8 HP Netserver LXr 8500 with XP256 Config Guide for Windo - Page 4

Intra-cluster Heartbeat LAN, Client LAN

Page 4 highlights

LANs LAN connection NIC: Model Driver No. of NICs SPU I\O slot Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or equivalent The intra-cluster LAN may only be used for cluster node communication via a crossover cable. It may not be used for client communication. Client LAN Any LAN HP D5013A (10/100TX PCI) 3.27.00.0001 or later 1 P4 Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. Any driver NOTE If the NIC used is the same as the Intra-cluster LAN, then the Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum P3 4

  • 1
  • 2
  • 3
  • 4
  • 5

4
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or
equivalent
Any LAN
The intra-cluster LAN may only be
used for cluster node communication
via a crossover cable.
It may not be
used for client communication.
NIC:
Model
HP D5013A
(10/100TX PCI)
Any that is on both the HP Tested
Products List and the Microsoft
Hardware Compatibility List.
Driver
3.27.00.0001 or
later
Any driver
NOTE
If the NIC used is the
same as the Intra-cluster LAN,
then the Client LAN must use the
same driver as the Intra-cluster
LAN.
No. of NICs
1
1 minimum
SPU I\O slot
P4
P3