HP NetServer LXr Pro8 HP Netserver LXr 8500 NetRAID-3Si Config Guide for Wind - Page 2

Storage

Page 2 highlights

Power source System software: Navigator version Operating System SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Direct from power mains, power conditioner or uninterruptible power supply (UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. L.18.00 or later Microsoft Windows 2000 Advanced Server HP NetServer LXr 8500 700 MHz 2 - 8 ASPN Release 8 Any size 256 MB minimum. Must be HP. 3 See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, PCI-1, PCI-2, SCSI A, SCSI B, PCI-3, PCI-4, PCI-5 through PCI-10 P3 - Intra-cluster (Heartbeat) LAN - D5013B P4 - Client LAN - D5013B P5 - Local storage - NetRAID-1Si P6 - Shared storage - NetRAID-3Si Booted from NetRAID-1Si Local Controller Driver Physical drive location Disk drives SCSI bus SCSI Ids Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SCSI ID May use embedded SCSI, NetRAID-1Si or NetRAID-3Si. For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD or later. For NetRAID-xSi, use mraid35x.sys version 2.62 (Navigator L.18.04.5 or later). SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed Any HP NetRAID-3Si Adapter D5955A 1 W.01.30 B.02.02 Mraid35x.sys 2.62 A.01.15 or later 6, 7 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.18.00 or later
Operating System
Microsoft Windows 2000 Advanced Server
SPU
Model
HP NetServer LXr 8500
Clock speed
700 MHz
No. of CPUs
2 – 8
BIOS version
ASPN Release 8
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
3
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, PCI-1, PCI-2, SCSI A, SCSI B, PCI-3, PCI-4, PCI-5 through
PCI-10
M/S Certified
Configuration
P3 – Intra-cluster (Heartbeat) LAN – D5013B
P4 – Client LAN – D5013B
P5 – Local storage – NetRAID-1Si
P6 – Shared storage – NetRAID-3Si
Booted from NetRAID-1Si
Storage
Local
Controller
May use embedded SCSI, NetRAID-1Si or NetRAID-3Si.
Driver
For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD or
later.
For NetRAID-xSi, use mraid35x.sys version 2.62 (Navigator L.18.04.5 or later).
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12)
Disk drives
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
SCSI Ids
Any
Shared
Controller
Model
HP NetRAID-3Si Adapter D5955A
No. of controllers
1
Firmware
W.01.30
BIOS
B.02.02
Driver
Mraid35x.sys
2.62
NetRAID Assistant
A.01.15 or later
SCSI ID
6, 7