HP P2000 HP P2000 G3 1GbE iSCSI MSA and 10GbE iSCSI MSA Controller Firmware TS - Page 6

Abort Verify Vdisk, Add Remote System - configuration

Page 6 highlights

◦ If a partner controller is restarted during replication, settings in the Scheduler will now be maintained; no extraneous replication images will be created. ◦ Replication schedules will no longer cause the SMU to time out and become unresponsive. ◦ Improved the messaging when attempting to detach a secondary replication volume and an initial replication has not occurred. ◦ When creating replication sets, if network settings are configured incorrectly, the correct error message will now be displayed. ◦ Snapshot sync points will now be displayed correctly. ◦ No snapshots will be taken after the schedule has expired. ◦ The controller will no longer hang when trying to add an invalid Remote Snap destination-volume. • The following fixes are specific to the Storage Management Utility (SMU): ◦ The Provisioning wizard will now permit a vdisk to be created with 128 volumes. ◦ On the Add Remote System page, the Password field could be left blank. A valid entry is now required. ◦ Reworded the message displayed for the Rename Host task. ◦ Online help was updated to reflect that no progress bar or message will be displayed when a roll back is in progress. ◦ Single-ported SATA drives installed in cascaded HP D2700 drive enclosures will now show the correct status information; they will no longer be displayed as "degraded". ◦ Corrected name and fan information displayed for D2700 drive enclosures. ◦ When running the Verify Vdisk utility, the Abort Verify Vdisk button will no longer be grayed-out. • The following fixes are specific to the Command Line Interface (CLI): ◦ For scripted CLI, removed an issue that caused the controller to crash and generate communication errors. ◦ set cache-parameters command: If the command syntax is correct, the "An invalid device was specified" message will no longer be displayed. ◦ create vdisk command: The assigned-to parameter will now be ignored when in single-controller mode. ◦ set cli-parameters command: Will now be recorded in the specified locale language, not the previous locale language. ◦ set cli-parameters and show cli-parameters commands: Corrected wording inconsistency in the online help. ◦ create volume-set command: Updated online help. ◦ vdisk shutdown command: A vdisk that has been stopped will now display the Status as STOP, and the Health as Unknown. ◦ set advanced settings command: The following parameter settings are now recognized: enable, enabled, disable, and disabled. ◦ show controllers command: Corrected the display to remove the possibility of a rare display of an unclear error message. ◦ show replication-volumes command: Corrected the display. ◦ create user command: If conflicting base and storage-size-base parameters are both set, an error message will now be displayed. 6 Fixes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

If a partner controller is restarted during replication, settings in the Scheduler will now be
maintained; no extraneous replication images will be created.
Replication schedules will no longer cause the SMU to time out and become unresponsive.
Improved the messaging when attempting to detach a secondary replication volume and an
initial replication has not occurred.
When creating replication sets, if network settings are configured incorrectly, the correct
error message will now be displayed.
Snapshot sync points will now be displayed correctly.
No snapshots will be taken after the schedule has expired.
The controller will no longer hang when trying to add an invalid Remote Snap
destination-volume.
The following fixes are specific to the Storage Management Utility (SMU):
The Provisioning wizard will now permit a vdisk to be created with 128 volumes.
On the
Add Remote System
page, the
Password
field could be left blank. A valid entry is
now required.
Reworded the message displayed for the
Rename Host
task.
Online help was updated to reflect that no progress bar or message will be displayed when
a roll back is in progress.
Single-ported SATA drives installed in cascaded HP D2700 drive enclosures will now show
the correct status information; they will no longer be displayed as “degraded”.
Corrected name and fan information displayed for D2700 drive enclosures.
When running the
Verify Vdisk
utility, the
Abort Verify Vdisk
button will no longer be
grayed-out.
The following fixes are specific to the Command Line Interface (CLI):
For scripted CLI, removed an issue that caused the controller to crash and generate
communication errors.
set cache-parameters
command: If the command syntax is correct, the “An invalid
device was specified” message will no longer be displayed.
create vdisk
command: The
assigned-to
parameter will now be ignored when in
single-controller mode.
set cli-parameters
command: Will now be recorded in the specified locale language,
not the previous locale language.
set cli-parameters
and
show cli-parameters
commands: Corrected wording
inconsistency in the online help.
create volume-set
command: Updated online help.
vdisk shutdown
command: A vdisk that has been stopped will now display the Status as
STOP
, and the Health as
Unknown
.
set advanced settings
command: The following parameter settings are now recognized:
enable
,
enabled
,
disable
, and
disabled
.
show controllers
command: Corrected the display to remove the possibility of a rare
display of an unclear error message.
show replication-volumes
command: Corrected the display.
create user
command: If conflicting
base
and
storage-size-base
parameters are
both set, an error message will now be displayed.
6