cont'd, timed tracking
View all HP ProLiant 1500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
ECG036/1297 7(&+12/2*< %5,() (cont'd) ... Tape tracks ATF area Data area Tape Edge Read/write head Tape tracks Figure 4: By reading ATF information from tracks immediately left and right of the primary track it is reading, the head centers its position on the track. The Compaq 12/24 GB DAT Drive does not use embedded servo tracking with ATF. Instead, it uses a timed tracking scheme that frees the ATF areas for user data, thus increasing the storage capacity. Timed tracking is a track-following servo format that provides servo input by measuring the time required for read or write heads to scan from the tape edge to a known reference point on the track. These reference points are equally-spaced "timing marks." By referencing from the edge of the tape, the drive is able to measure the time it takes to reach the timing mark (Figure 5). Any deviation in time indicates a deviation from the track centerline. If the timing is too early, the tape speed increases to center the head on the track; if it is too late, the tape speed decreases. This process increases efficiency and performs head/track alignment more frequently than the embedded servo format. The timed tracking format does not require ATF storage on the track, so more of the track is available for storing user data. Timing mark Tape Edge Early Late "On-time" Figure 5: Timed tracking servo.