HP ProLiant BL35p HP BladeSystem Management Pack for Microsoft System Center E - Page 56
Rack power subsystem input voltage problem, Power Supply Input Line Status '%9
View all HP ProLiant BL35p manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
NT Event Message: Rack Power Subsystem Not Redundant. This trap signifies that the rack power subsystem is no longer in a redundant state. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state. Source IP Address: '%1'; Source Name: '%2'; Rack Name: '%4'; Rack Unique ID: '%5'; Enclosure Name '%6'; Enclosure Serial Number '%7'; Trap Sequence Number '%8' [SNMP TRAP: 22018 in CPQRACK.MIB] Onboard Administrator Web Console Rack power subsystem input voltage problem NT Provider: Blade Enclosure NT Event ID: 22019 NT Event Type: Warning NT Event Message: Rack Power Subsystem Input Voltage Problem. This trap signifies that the rack power supply detected an input line voltage problem. User Action: Check the power input for the power supply or replace any failed power supplies as soon as possible. Source IP Address: '%1'; Source Name: '%2'; Rack Name: '%4'; Rack Unique ID: '%5'; Enclosure Name '%6'; Power Supply Position '%7'; Power Supply Firmware Revision '%8'; Power Supply Input Line Status '%9' (Power Supply Input Line Status values: 1=no error, 2=over voltage, 3=under voltage, 4=line hit, 5=brown out, 6=line power loss); Power Supply Spare Part Number '%10'; Enclosure Serial Number '%11'; NT Event lists for HP BladeSystem Enclosure Monitor Service 56