HP ProLiant BL420c HP Smart Update Manager 5.1 Release Notes - Page 10
HP ProLiant Issues
View all HP ProLiant BL420c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
NOTE: If the VCs are managed by HP Virtual Connect Enterprise Manager (VCEM), they must first be put into maintenance mode before HP SUM can perform the VC firmware updates. After they are in maintenance or firmware mode, HP SUM 5.1.0 and SPP 2012.6.0 can be used to update them. After the update, put the VCs back into normal production mode. Virtual Connect (VC) update stops after discovery and installation never begins if the Onboard Administrator credentials are different from the VC credentials VC update stops after discovery and installation fails to initiate if the Onboard Administrator (OA) credentials are different from the VC credentials. This only occurs when using the command line and Input File modes for HP SUM. Suggested action: Use HP SUM in GUI mode. HP SUM for Linux might take longer than 30 minutes to build RPMs on SUSE Linux Enterprise System 10 Due to the amount of source RPMs that need to build and the build time of each, the build process may take longer than 30 minutes. Suggested action: For more information about resolving this issue, see the Customer Advisory c03114183 on the HP support website at: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c03114183 HP SUM shows a target is still being discovered when no longer selected On the Select Target screen, if a target is no longer selected while still being discovered, the discovery process will continue. Suggested action: No action required. You can proceed with the installation as normal. In HP SUM for Windows Japanese version 5.0.0 and later, if you enter incorrect CLI parameters, HP SUM returns a corrupted string If you enter incorrect parameters, a HP SUM returns a corrupted string instead of displaying an error message. Suggested action: If HP SUM returns a corrupted string, verify that the parameters are correct. HP SUM for Windows and Linux RPM configuration screen has not been localized into Japanese The RPM configuration screen has not been localized into Japanese. Suggested action: There is nothing you need to do, this is expected behavior. HP ProLiant Issues HP SUM for Linux might not list the HP Ethernet 10Gb 2-port 530FLR-SFP+/ 530FLB/530M NIC FW until the driver is installed and the Ethernet ports are enabled HP SUM will not discover Broadcom NIC firmware physically attached to the server unless the drivers are installed and all the NICs Ethernet ports are open. Suggested action: To update the firmware for Broadcom NICs in Linux, use the following steps: 1. Install the bnx2x driver found in the SPP package, the SDR, or the Linux distribution. 2. Enable all the Ethernet ports. 3. Run the Broadcom FW upgrade component. 10 Issues and suggested actions