HP ProLiant BL620c HP StorageWorks Emulex Adapters Release Notes (AA-RWQ7C-TE, - Page 13

CNA/HBA Linux notes

Page 13 highlights

Ethernet Jumbo Packet The CN1000E maximum supported Ethernet Jumbo Packet frame size is 8192 bytes. Optical cable length The CN1000E maximum supported optical cable length is 40 meters. Boot from SAN DL16x and DL18x Servers require extra time to boot from SAN. When the CN1000E adapter is used as the boot device in a DL16x or DL18x server, the server may pause for approximately 90 seconds when it is expected to start booting from the hard disk. After this delay, the boot process resumes as expected. Update DL/SL100-series BIOS before installing CN1000e Before installing an HP CN1000e into a DL/SL100-series server, you must upgrade the server BIOS to 2010.02.04 or later. The BIOS is available for download from the HP Download Drivers and Software website: http://www.hp.com/support/downloads Compatibility/interoperability HP recommends that you implement zoning by CNAs/HBAs, as described in the HP StorageWorks SAN Design Reference Guide, available at: http://www.hp.com/go/sdgmanuals FC2142SR and FC2242SR HBAs on ProLiant systems HP ProLiant DL380 (G4) servers must have System ROMPaq firmware 4.05 P51-08/16/2005 or later to be compatible with the FC2142SR and FC2242SR. Failure to use this ROMPaq version can cause the HBAs to hang during the power-on self-test (POST). For more information, see the HP website: http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=en&cc=us& swItem=MTX-f8105bcfcba8403f8b793e23f5&jumpid=reg_R1002_USEN CNA/HBA Linux notes This section describes restrictions that apply to Linux and this release of the CNAs/HBAs: • Firmware download in SLES 10 SP3 can cause the system to hang. When downloading firmware to the CN1000E adapters in SLES 10 SP3 using the OneCommand Manager or hbacmd, the download may complete but cause the system to become unresponsive or hang. Though the firmware download is successful, a hard reboot of the server may be required to enable the new firmware. • HP and Novell are evaluating a report that Reiserfs filesystems display unexpected behavior under heavy load. Other filesystems such as xfs and ext3 are not affected by this behavior. HP recommends that you use either the xfs or ext3 filesystem. This is a high priority issue that is in HP StorageWorks Emulex Adapters Release Notes 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Ethernet Jumbo Packet
The CN1000E maximum supported Ethernet Jumbo Packet frame size is 8192 bytes.
Optical cable length
The CN1000E maximum supported optical cable length is 40 meters.
Boot from SAN
DL16x and DL18x Servers require extra time to boot from SAN.
When the CN1000E adapter is used as the boot device in a DL16
x
or DL18
x
server, the server may
pause for approximately 90 seconds when it is expected to start booting from the hard disk. After
this delay, the boot process resumes as expected.
Update DL/SL100-series BIOS before installing CN1000e
Before installing an HP CN1000e into a DL/SL100-series server, you must upgrade the server BIOS
to 2010.02.04 or later. The BIOS is available for download from the HP Download Drivers and
Software website:
h
t
tp://w
w
w
.hp
.co
m/su
ppo
r
t/do
w
nloads
Compatibility/interoperability
HP recommends that you implement zoning by CNAs/HBAs, as described in the
HP StorageWorks
SAN Design Reference Guide
, available at:
h
t
tp://w
w
w
.hp
.co
m/go/sdgman
uals
FC2142SR and FC2242SR HBAs on ProLiant systems
HP ProLiant DL380 (G4) servers must have System ROMPaq firmware 4.05 P51-08/16/2005 or
later to be compatible with the FC2142SR and FC2242SR. Failure to use this ROMPaq version can
cause the HBAs to hang during the power-on self-test (POST). For more information, see the HP website:
h
t
tp://h20000.w
w
w2
.hp
.co
m/b
i
zsu
ppo
r
t/T
ec
hSu
ppo
r
t/S
o
f
t
w
ar
eD
e
s
c
r
ipti
o
n
.js
p?lang=e
n&cc=u
s&
s
wIt
e
m=MTX
-f810
5bcfcba8
4
0
3f8b7
9
3e2
3f5&
j
um
p
i
d=r
eg_R100
2_U
SEN
CNA/HBA Linux notes
This section describes restrictions that apply to Linux and this release of the CNAs/HBAs:
Firmware download in SLES 10 SP3 can cause the system to hang.
When downloading firmware to the CN1000E adapters in SLES 10 SP3 using the OneCommand
Manager or
hbacmd
, the download may complete but cause the system to become unresponsive
or hang. Though the firmware download is successful, a hard reboot of the server may be required
to enable the new firmware.
HP and Novell are evaluating a report that
Reiserfs
filesystems display unexpected behavior
under heavy load. Other filesystems such as
xfs
and
ext3
are not affected by this behavior. HP
recommends that you use either the
xfs
or
ext3
filesystem. This is a high priority issue that is in
HP StorageWorks Emulex Adapters Release Notes
13