HP ProLiant SL165s HP ProLiant SL6000 Scalable System technology, 2nd Edition - Page 11

Display and Log Power Status and Configuration, Copyright c 2003

Page 11 highlights

We provide a simple command-line utility, called PPIC, to read and configure the power control logic in the SL6500 Scalable System. Versions are available for Microsoft® Windows® Server 2003 and 2008 and for the Linux® operating system after installing the OS IPMI driver. Running the PPIC utility from the command line without any command-line options will provide the options shown below. HP ProLiant Power Interface Control Utility v.1.09 Copyright (c) 2003, 2009 Hewlett-Packard Development Company, L.P. Usage: POW [Options] options: -d Display and Log Power Status and Configuration -v verbose data displayed -s Set Power Configuration Mode -m Disabled) 00= No Redundancy Mode (Power Throttling Performance w/ 01= AC Redundancy with Throttling Mode (Max Redundancy) 02= Full AC/DC Redundancy Mode License 03= User Configurable Mode (LO100 Advanced Required) -l (in Watts - Required for

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

11
We provide a simple command-line utility, called PPIC, to read and configure the power control logic
in the SL6500 Scalable System. Versions are available for Microsoft
®
Windows
®
Server 2003 and
2008 and for the Linux
®
operating system after installing the OS IPMI driver. Running the PPIC utility
from the command line without any command-line options will provide the options shown below.
HP ProLiant Power Interface Control Utility v.1.09
Copyright (c) 2003, 2009 Hewlett-Packard Development Company, L.P.
Usage: POW [Options]
options:
-d
Display and Log Power Status and Configuration
-v
verbose data displayed
-s Set Power Configuration Mode
-m<mode>
00= No Redundancy Mode (Power Throttling
Disabled)
01= AC Redundancy with Throttling Mode (Max
Performance w/
Redundancy)
02= Full AC/DC Redundancy Mode
03= User Configurable Mode (
LO100 Advanced
License
Required
)
-l<power limit> (in Watts - Required for <Mode 03)
-c
Calibrate and Display Power Limits
-p
Poll and Log Power Readings
-v
verbose data logged
-f<frequency> (in secs)
-t<duration of run> (in secs)
-o<name> override output log filename
(default log filename= ppic.log)
Power control logic in the z6000 G6 chassis operates in one of four possible modes (Table 2).