HP ProLiant SL6500 HP ROM-Based Setup Utility User Guide - Page 149
System, Options > SATA Controller Options, Enabled, Disabled, Drive Write Cache
View all HP ProLiant SL6500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 149 highlights
Drive Write Cache NOTE: This option is available on G7 servers. For Gen8 servers, this option is in under System Options > SATA Controller Options ("Drive Write Cache" (page 43)) The Drive Write Cache option controls the state of the write cache of the drives attached to the supported controller. This feature provides greater drive performance but could result in data corruption during an unexpected power loss or shutdown. This option only affects operation for fixed drives attached to the embedded SATA controller when not operating in a software RAID mode. This option has no effect if fixed drives are attached to an embedded or optional Smart Array controller or if the Smart Array B110i Software RAID solution is used. CAUTION: Enabling Drive Write Cache may result in data loss or data corruption if an unexpected power loss occurs. After reading the warning message, press any key to display the following settings: • Enabled • Disabled (default) Advanced Options menu 149