- HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 1
WS460c Gen8 Workstation Blade with WS460c Graphics Expansion Blade User Guide Abstract This guide provides operation information for the HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graphics Expansion Blade. This guide is for technicians that install, administer, and troubleshoot servers - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 2
statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft®, Windows®, and Windows Server® are U.S. registered trademarks of Microsoft - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 3
the WS460c Graphics Expansion Blade PCIe card cage 23 Remove the NVIDIA Quadro K4000 graphics card 26 Remove the NVIDIA Quadro K5000 graphics card 27 Remove the NVIDIA GRID K2 I/O Plate ...28 Setup...32 Overview ...32 Installing an HP BladeSystem c-Class enclosure 32 Installing server blade - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 4
...62 Troubleshooting resources ...62 Software and configuration utilities 63 Server mode ...63 HP product QuickSpecs...63 HP iLO Management Engine ...63 HP iLO ...63 Intelligent Provisioning...65 Scripting Toolkit ...67 HP Service Pack for ProLiant ...67 HP Smart Update Manager...67 HP ROM-Based - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 5
methods to prevent electrostatic discharge 77 Specifications ...78 Environmental specifications ...78 Server blade specifications ...78 Support and other resources ...79 Before you contact HP...79 HP contact information ...79 Customer Self Repair ...79 Acronyms and abbreviations...87 Documentation - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 6
Hard drive bay 1 Server blade release button Server blade release lever Hard drive bay 2 HP c-Class Blade SUV connector* (behind the serial label pull tab) Serial label pull tab *The SUV connector and the HP c-Class Blade SUV Cable are used for some workstation blade configuration and diagnostic - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 7
Front panel components for workstation blade with graphics expansion blade Item Description 1 Serial label pull tab 2 HP c-Class Blade SUV connector* (behind the serial label pull tab) 3 Drive bay 2 4 Drive bay 1 5 Server blade release lever 6 Server blade release button * The SUV - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 8
LED pressed. Solid Amber = System is in standby; Power On/Standby button service is initialized. Off and the Health Status LED bar is off = The or activity Front panel LEDs and buttons for workstation blade with graphics expansion blade Item Description Status 1 Health status LED Solid - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 9
Status pressed. Solid Amber = System is in standby; Power On/Standby button service is initialized. Off and the Health Status LED bar is off = The drive is rebuilding or performing a RAID migration, strip size migration, capacity expansion, or logical drive extension, or is erasing. The drive is a - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 10
is not configured by a RAID controller. System board components Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Description HP c-Class Blade SUV Cable HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graphics Expansion Blade Installation Instructions on the HP website (http://www.hp.com/support - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 11
CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to properly configure the server or data loss could occur. Mezzanine (1 through 8) for each processor. The supported AMP modes use the alpha assignments for population order, and the slot numbers designate the DIMM - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 12
points to the front of the workstation blade. DIMM tool location The DIMM tool is used to open and close an empty DIMM slot. HP c-Class Blade SUV Cable Item Connector 1 Server blade Description For connecting to the SUV connector on the workstation blade front panel Component identification 12 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 13
Item Connector 2 Video 3 USB 4 Serial Description For connecting a video monitor For connecting up to two USB devices For trained personnel to connect a null modem serial cable and perform advanced diagnostic procedures Component identification 13 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 14
and installation guide on the HP website (http://www.hp.com/support/oa). For more information about iLO 4, see "HP iLO (on page 63)." Power down the workstation blade Before powering down the workstation blade for any upgrade or maintenance procedures, perform a backup of critical server data and - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 15
This command initiates a controlled shutdown of applications and the OS before the workstation blade enters standby mode. o poweroff server [bay number] force This form of the command forces the workstation blade to enter standby mode without properly exiting applications and the OS. If an - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 16
panel 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. If necessary, remove the graphics expansion blade ("Remove the WS460c Graphics Expansion Blade PCIe card cage" on page 23, "Remove the WS460c Graphics Expansion Blade" on page 21). 4. Press - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 17
Remove the DIMM baffle 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. Remove the access panel (on page 16). 4. Disconnect the capacitor pack cabling, if connected ("FBWC capacitor pack cabling" on page 59). 5. Remove - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 18
o DIMM baffle (right side) Remove the SAS controller 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. Remove the access panel (on page 16). 4. Disconnect the capacitor pack cabling, if connected ("FBWC capacitor pack cabling" on page 59). CAUTION: - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 19
5. Remove the SAS controller. Install the SAS controller 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. Remove the access panel (on page 16). 4. Disconnect the FBWC battery pack cabling, if connected ("FBWC capacitor pack cabling" on page 59). - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 20
the SAS controller, press firmly in the areas indicated on the SAS controller. Remove the WS460c Graphics Expansion Blade access panel 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. Lift the access panel latch (1), and then slide the access panel - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 21
Remove the WS460c Graphics Expansion Blade 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. Remove the WS460c Graphics Expansion Blade access panel (on page 20). 4. Remove the screws (1) and the front bezel (2). 5. Remove the gasket. Operations 21 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 22
6. Disconnect the power cable from the upper mezzanine card (1), and then disconnect the other end of the power cable (2). 7. Disconnect the signal cable from the lower mezzanine cards: a. Apply pressure to the lower mezzanine card (1), squeeze the latch (2), and then disconnect the signal cable - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 23
slide the graphics expansion blade back, and lift it up (2) from the workstation blade. Remove the WS460c Graphics Expansion Blade PCIe card cage 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. Remove the WS460c Graphics Expansion Blade access panel - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 24
5. Remove the gasket. 6. Disconnect the power cable from the upper mezzanine card, and then disconnect the other end of the power cable. 7. Disconnect the signal cable from the lower mezzanine card: a. Apply pressure to the lower mezzanine card (1), squeeze the latch (2), and then disconnect the - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 25
b. Disconnect the other end of the signal cable (4). 8. Remove the retaining block. Operations 25 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 26
the server) • HP Insight Diagnostics software For basic installation instructions, follow these steps. For more specific installation information, see the HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graphics Expansion Blade Maintenance and Service Guide. 1. Power down the workstation blade - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 27
up the workstation blade. 15. Download and install the latest drivers from the HP (http://www.hp.com) or NVIDIA website. For software installation information, see the Microsoft Windows on HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graphics Expansion Blade Administrator Guide. Remove the - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 28
. Power up the workstation blade. 11. Download and install the latest drivers from the HP or NVIDIA website. For software installation information, see the Microsoft Windows on HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graphics Expansion Blade Administrator Guide. Remove the NVIDIA GRID - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 29
• M2.5x6 mm flat head screws (2) To remove the graphics cards from the graphics expansion blade: 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. Remove the screws and washers. 4. Align the plate to the board assembly, and then insert both tabs - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 30
If the screws lack Nylok coating or are used, add Loctite 242 Threadlocker 3~5 threads from the tip. 6. Install M2.5x6 mm wafer head screws (the same screws removed in step 1) through the heat spreader, plate tab, and process control board hole alignment to the baseplate, and then torque both screws - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 31
up the workstation blade. 10. Download and install the latest drivers from the HP (http://www.hp.com) or NVIDIA website. For software installation information, see the Microsoft Windows on HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graphics Expansion Blade Administrator Guide. Operations - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 32
Connect the interconnect modules to the network. 5. Install a workstation blade. 6. Complete the workstation blade configuration. Installing an HP BladeSystem c-Class enclosure Before performing any workstation blade-specific procedures, install an HP BladeSystem c-Class enclosure. The most current - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 33
Interconnect bay numbering and device mapping • HP BladeSystem c7000 Enclosure To support network connections for specific signals, install an interconnect module in the bay corresponding to the FlexibleLOM or mezzanine signals. Server blade signal FlexibleLOM Mezzanine 1 Mezzanine 2 Interconnect - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 34
cards • Ports 1 and 3 connect to bay 3. • Ports 2 and 4 connect to bay 4. Connecting to the network To connect the HP BladeSystem to a network, each enclosure must be configured with network interconnect devices to manage signals between the workstation blades and the external network. Setup 34 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 35
Virtual Connect to the correct version before installing an HP ProLiant Gen8 workstation blade. The version information is located on the tag on the front of the workstation blade. For more information on this and other specific firmware and driver requirements, as well as the latest firmware and - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 36
2. Remove the enclosure connector cover. 3. Install the workstation blade. Completing the configuration To complete the workstation blade and HP BladeSystem configuration, see the overview card that ships with the enclosure. Setup 36 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 37
than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge. Drive option The workstation blade supports up to - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 38
prevent possible workstation blade malfunction and damage to the equipment, multiprocessor configurations must HP website (http://www.hp.com/support). Follow the instructions on the website to update the system ROM. 2. Power down the workstation blade (on page 14). 3. Remove the workstation blade - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 39
6. Remove the heatsink blank. Retain the heatsink blank for future use. 7. Open each of the processor locking levers in the order indicated, and then open the processor retaining bracket. Hardware options installation 39 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 40
for future use. 9. Install the processor. Verify that the processor is fully seated in the processor retaining bracket by visually inspecting the processor installation guides on either side of the processor. THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. CAUTION: THE PINS ON THE - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 41
CAUTION: Do not press down on the processor. Pressing down on the processor may cause damage to the processor socket and the system board. Press only in the area indicated on the processor retaining bracket. 11. Press and hold the processor retaining bracket in place, and then close each processor - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 42
workstation blade can support LRDIMMs, RDIMMs, or UDIMMs: • UDIMMs represent the most basic type of memory module and offer lower latency in one DIMM per channel configurations only. All memory installed in the workstation blade must be the same type. The server supports the following DIMM speeds: • - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 43
level as 1.5V memory. For example, while the industry supports DDR3-1333 RDIMM at 1.5V, compared to 1.8V for DDR-2 DIMMs. DDR3 Low Voltage DIMMs operate at 1.35V. For HP ProLiant Gen8 servers, the majority of new DDR3 DIMMs are Low Voltage as HP SmartMemory enables the same performance as 1.5V. This - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 44
server are identified by number and by letter. Letters identify the population order. Slot numbers indicate the DIMM slot ID for spare replacement. Single-, dual-, and quad-rank DIMMs To understand and configure accessible at a time. The workstation blade memory control subsystem selects the proper - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 45
QuickSpecs on the HP website (http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html). At the website, choose the geographic region, and then locate the product by name or product category. Memory configurations To optimize workstation blade availability, the workstation blade supports - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 46
(DDDC). Running in independent mode, the server can only survive the complete failure of a configuration information, see the QuickSpecs on the HP website (http://www.hp.com). Advanced ECC memory configuration Advanced ECC memory is the default memory protection mode for this workstation blade - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 47
the DIMMs per slot number as instructed by the system software. For detailed memory configuration rules and guidelines, use the Online DDR3 Memory Configuration Tool on the HP website (http://www.hp.com/go/ddr3memory-configurator). DIMM speeds are supported as indicated in the following table - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 48
, or lockstep memory support. Installing a DIMM CAUTION: To avoid damage to the hard drives, memory, and other system components, the air baffle, drive blanks, and access panel must be installed when the server is powered up. 1. Power down the server ("Power down the workstation blade" on page 14 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 49
option on mezzanine connector 2, processor 2 must be installed. For mezzanine card mapping, see the HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graphics Expansion Blade Installation Instructions or see "Interconnect bay numbering and device mapping (on page 33)." To install the component - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 50
4. Remove the mezzanine assembly from the workstation blade. 5. Align the mezzanine card with the guide pins on the mezzanine assembly. Hardware options installation 50 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 51
guide pins on the system board, and then install the mezzanine assembly on the system board. 8. Press down firmly on the mezzanine assembly handles, and then close the mezzanine assembly latch. 9. Install the access panel (on page 16). 10. Install the workstation blade ("Installing a server blade - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 52
the workstation blade. The procedure for replacing these particular graphics cards on the graphics expansion blade is different, and must be performed by HP service personnel only. Required tools for this procedure: • T-10/T-15 Torx screwdriver (provided inside the server) • HP Insight Diagnostics - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 53
guide pins on the mezzanine assembly. 2. Install the mezzanine card in the mezzanine assembly, and then to secure the card to the mezzanine assembly, tighten the mezzanine card screws. The installation is complete. FBWC capacitor pack To install the component: 1. Power down the workstation blade - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 54
o FBWC capacitor pack for the SAS controller o FBWC capacitor pack for a mezzanine option. 5. Route the FBWC capacitor pack cable. The DIMM baffles may be removed to route the cables, if necessary. Hardware options installation 54 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 55
about product features, specifications, options, configurations, and compatibility, see the product QuickSpecs on the HP Product Bulletin website (http://www.hp.com/go/productbulletin). Use these instructions to install and enable a TPM on a supported workstation blade. This procedure includes three - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 56
• When installing or replacing hardware, HP service providers cannot enable the TPM or the HP is not liable for blocked data access caused by improper TPM use. For operating instructions the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. Place the workstation blade on - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 57
19). 13. Install the DIMM baffle. 14. Install the access panel (on page 16). 15. Install the workstation blade ("Installing a server blade" on page 35). 16. Power up the workstation blade (on page 14). Retaining the recovery key/password The recovery key/password is generated during BitLocker™ setup - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 58
the workstation blade. 8. Enable the TPM in the OS. For OS-specific instructions, see the OS documentation. CAUTION: When a TPM is installed and enabled on the workstation blade, , see the HP Trusted Platform Module Best Practices White Paper on the HP website (http://www.hp.com/support). For more - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 59
the mezzanine option For capacitor pack and cabling instructions, see "FBWC capacitor pack (on page 53)." Using the HP c-Class Blade SUV Cable The HP c-Class Blade SUV Cable enables the user to perform workstation blade administration, configuration, and diagnostic procedures by connecting video and - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 60
configurations are possible. This section offers two possible configurations. For more information, see "USB support (on page 72)." Accessing a server blade with local KVM For this configuration pull tab and connect the HP c-Class Blade SUV Cable to the workstation blade. 2. Connect the video - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 61
when configuring a workstation blade or loading software updates and patches from a USB CD/DVD-ROM. Use a USB hub when connecting a USB CD-ROM drive to the workstation blade. The USB hub provides additional connections. 1. Open the serial label pull tab and connect the HP c-Class Blade SUV - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 62
(http://www.hp.com/support/ProLiant_TSG_v1_sc) The HP ProLiant Gen8 Troubleshooting Guide, Volume II: Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades. To view the guide, select a language - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 63
, configurations, and compatibility, see the product QuickSpecs on the HP Product Bulletin website (http://www.hp.com/go/productbulletin). HP iLO Management Engine The HP iLO Management Engine is a set of embedded management features supporting the complete lifecycle of the workstation blade, from - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 64
alerts from iLO 4 regardless of the state of the host workstation blade. • Access Active Health System troubleshooting features through the iLO 4 interface. • Subscribe to HP Insight Remote Support software without installing any drivers or agents. For more information about iLO 4 features (which - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 65
workstation blade as part of HP iLO Management Engine's Intelligent Provisioning. Intelligent Provisioning is an essential single-server deployment tool embedded in HP ProLiant Gen8 servers that simplifies HP ProLiant server setup, providing a reliable and consistent way to deploy HP ProLiant server - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 66
in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify workstation blade installations, troubleshoot problems, and perform repair validation. HP Insight Diagnostics Offline Edition performs various in-depth system and - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 67
• Remote (one-to-many) online deployment of HP ProLiant servers and enclosures • Local offline firmware deployments with HP Support Pack for ProLiant deliverables • Remote offline deployment when used with the Scripting Toolkit (HP ProLiant Gen8 and later), iLO Virtual Media, or PXE booted - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 68
Switch interconnects on HP ProLiant servers For more information about HP SUM and to access the HP Smart Update Manager User Guide, see the HP website (http://www.hp.com/go/hpsum/documentation). HP ROM-Based Setup Utility RBSU is a configuration utility embedded in HP ProLiant servers that performs - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 69
F11 key. • Force a PXE Network boot by pressing the F12 key. Configuring AMP modes Not all HP ProLiant servers support all AMP modes. RBSU provides menu options only for the modes supported by the server. Advanced memory protection within RBSU enables the following advanced memory modes: • Advanced - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 70
RBSU. The workstation blade automatically reboots. Utilities and features Array Configuration Utility ACU is a utility with the following features: • Runs as a local application or remote service accessed through the HP System Management Homepage • Supports online array capacity expansion, logical - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 71
, starting with HP ProLiant Gen8 servers. To access HP ProLiant Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 72
HP provides legacy USB functionality for the following: • POST • RBSU • Diagnostics • DOS • Operating environments which do not provide native USB support Redundant ROM support The workstation blade enables you to upgrade or configure the ROM safely with redundant ROM support. The workstation blade - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 73
that your workstation blade supports. To verify that your workstation blade is using the latest supported version and for more information about SPP, see the HP website (http://www.hp.com/go/spp/download). To locate the drivers for a particular server, go to the HP website (http://www.hp.com/go - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 74
to support HP business products. HP Insight Remote Support-Provides 24x7 secure remote monitoring, diagnosis, and problem resolution. For more information, see one of the following websites: • HP ProLiant Server Services website (http://www.hp.com/services/proliant) • HP BladeSystem Services website - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 75
the workstation blade no . To remove the component: 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. Remove the access panel board battery resets the system ROM to its default configuration. After replacing the battery, reconfigure the system through - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 76
HP ProLiant and X86 Servers and Options (http://www.hp.com/support/ProLiantServers-Warranties) HP Enterprise Servers (http://www.hp.com/support/EnterpriseServers-Warranties) HP Storage Products (http://www.hp.com/support/Storage-Warranties) HP Networking Products (http://www.hp.com/support - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 77
skin. • Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 78
of 95% is based on a maximum temperature of 45°C (113°F). †Maximum storage altitude corresponds to a minimum pressure of 70 kPa (10.1 psia). Server blade specifications Specification Height Depth Width Weight (maximum) Weight (minimum) Value 180.70 mm (7.11 in) 517.51mm (20.37 in) 55.37 mm (2.18 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 79
quality improvement, calls may be recorded or monitored. • If you have purchased a Care Pack (service upgrade), see the Support & Drivers website (http://www8.hp.com/us/en/support-drivers.html). If the problem cannot be resolved at the website, call 1-800-633-3600. For more information about Care - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 80
service designated for your product. NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that an authorized service you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 81
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. Support and other resources 81 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 82
Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert werden, können Sie - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 83
propio cliente de HP, póngase en HP siguiente (http://www.hp.com/go/selfrepair). Customer Self Repair Veel onderdelen in HP HP (of een HP Service HP Service HP Service Partner om via de telefoon technische ondersteuning te ontvangen. HP stico, a HP (ou fornecedores/parceiros de serviço da HP) concluir - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 84
transportadora/serviço postal a ser utilizado. Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP (http://www.hp.com/go/selfrepair). Support and other resources 84 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 85
Support and other resources 85 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 86
Support and other resources 86 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 87
and abbreviations ABEND abnormal end ACU Array Configuration Utility ADM Advanced Data Mirroring AMP Advanced Memory Protection ASR Automatic Server Recovery FBWC flash-backed write cache FC Fibre Channel HP SIM HP Systems Insight Manager HP SUM HP Smart Update Manager iLO Integrated Lights-Out - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 88
LV DIMM low-voltage DIMM ORCA Option ROM Configuration for Arrays POST Power-On Self Test PXE preboot execution environment RBSU ROM-Based Setup Utility RDIMM registered dual in-line memory module SAS serial - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 89
documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:[email protected]). Include the document title and part number, version number, or the URL when submitting your feedback. Documentation feedback 89 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 90
reseller 79 auto-configuration process 68 Automatic Server Recovery (ASR) 72 B Basic Input/Output System (BIOS) batteries, replacing 75 battery 10, 75 battery replacement notice 76 battery warranty 76 before you contact HP 79 BIOS (Basic Input/Output System) BIOS upgrade 63, 71 blade blank 35 boot - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 91
Insight Remote Support software 74 HP Service Pack for ProLiant 63, 67 HP Smart Update Manager overview 63, 67 HP technical support 74, 79 HP website 79 HP, contacting 79 I IML (Integrated Management Log) 63, 65 Insight Diagnostics 66, 73 installation, server blade 35 installation, server options 37 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 92
76 server blade release lever 6 server features and options 37 server options, installing 37 server specifications 78 Service Packs 67 setup 32 Smart Update Manager 63, 67 specifications 78 specifications, environmental 78 specifications, server blade 78 SPP 67 static electricity 77 support 79 - HP ProLiant WS460c | HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graph - Page 93
website, HP 79 Index 93
HP ProLiant WS460c Gen8 Workstation Blade
with WS460c Graphics Expansion Blade
User Guide
Abstract
This guide provides operation information for the HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graphics Expansion Blade. This
guide is for technicians that install, administer, and troubleshoot servers and storage systems.
Part Number: 703968-003
August 2013
Edition: 3