HP Scitex FB10000 Geffen TS Error 50041 - Page 2

Recommended Actions

Page 2 highlights

Error ID: 50041 - Motion - T-axis did not reach its Home position Recommended Actions T- axis H.P. Sensor Error 1. Open the Control Tools application in the T-Loading Unloading module tab. FB10000 Error Message Troubleshooting Top 2. Verify that the H.P. Sensor T indicator is OFF (Gray) - if it is ON please check the following: • Sensor is mechanically activated by the X motor - move the motor manually to clear the error! • The sensor is faulty or disconnected - replace it! 2

  • 1
  • 2
  • 3

Error ID: 50041 - Motion – T-axis did not reach its Home position
FB10000 Error Message Troubleshooting
Recommended Actions
T- axis H.P. Sensor Error
1.
Open the Control Tools application in the T-Loading Unloading module tab.
2.
Verify that the H.P. Sensor T indicator is
OFF
(Gray) – if it is
ON
please check the following:
Sensor is mechanically activated by the X motor – move the motor manually to clear the error!
The sensor is faulty or disconnected - replace it!
Top
2