HP Scitex FB10000 Geffen TS Error 50019 - Page 3

Check Motor Coupling, Check Wiring, Check B&R Functionality

Page 3 highlights

Error ID: 50019 - Media Handling - U1-axis did not reach its Home position. FB10000 Error Messages Troubleshooting Check Motor Coupling 1. Check Belt 2. Check pulley 3. Check coupling to motor Check Wiring 1. Check wiring path between Home sensor B&R module. 2. Check wiring between U1 sensor and B&R module. 3. Verify that ULB sensors on both sides of the loader beam are connected and functional. 4. Check motor coupling on the two motors on the loader beam. Top 5. Check wiring path between all sensors and their B&R modules. 6. Check wiring between ULB-axis encoders on both sides of the loader and their B&R module. Check B&R Functionality 1. Check wiring to B&R module. 2. Check B&R module sanity 3

  • 1
  • 2
  • 3

Error ID: 50019 – Media Handling – U1-axis did not reach its Home position.
FB10000 Error Messages Troubleshooting
Check Motor Coupling
1.
Check Belt
2.
Check pulley
3.
Check coupling to motor
Check Wiring
1.
Check wiring path between Home sensor B&R module.
2.
Check wiring between U1 sensor and B&R module.
3.
Verify that ULB sensors on both sides of the loader beam are connected and functional.
4.
Check motor coupling on the two motors on the loader beam.
5.
Check wiring path between all sensors and their B&R modules.
6.
Check wiring between ULB-axis encoders on both sides of the loader and their B&R module.
Check B&R Functionality
1.
Check wiring to B&R module.
2.
Check B&R module sanity
Top