Error ID: 66316 - UV - UV High Voltage Guard is Opened Motor windings are not properly connected 1. Check motor windings using a voltmeter with resistance measuring mode. • X5.A1- X5.A2 = 3Ω • X5.A2- X5.A3 = 3Ω • X5.A1- X5.A3 = 3Ω Frequency Inverter A5 and plug X5 are not properly connected 1. Check connections between inverter (A5) and plug (X5). 2. Switch off the cabinet and wait for 30 seconds. 3. After that, using a voltmeter in continuity check mode, perform the following checks. FB10000 Error Message Troubleshooting Top 4. Open the cabinet and check the display in the inverter. Compare it with the following tables: Note: Fault detection codes require a power reset after the fault is cleared. (See also Baldwin HMI Alarms No. 15 and 16) 3

  • 1
  • 2
  • 3
  • 4
  • 5

Error ID: 66316 - UV – UV High Voltage Guard is Opened
FB10000 Error Message Troubleshooting
Motor windings are not properly connected
1.
Check motor windings using a voltmeter with resistance measuring mode.
• X5.A1
- X5.A2 = 3
Ω
X5.A2- X5.A3 = 3
Ω
X5.A1- X5.A3 = 3
Ω
Frequency Inverter A5 and plug X5 are not properly connected
1.
Check connections between inverter (A5) and plug (X5).
2.
Switch off the cabinet and wait for 30 seconds.
3.
After that, using a voltmeter in continuity check mode, perform the following checks.
4.
Open the cabinet and check the display in the inverter. Compare it with the following tables:
Note:
Fault detection codes require a power reset after the fault is cleared.
(See also Baldwin HMI Alarms No. 15 and 16)