HP Scitex FB10000 Geffen TS Error 66118 - Page 2
Recommended actions
![]() |
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Error ID: 66118 - Unified Cooler - Ambient temperature out of range Recommended actions Ambient temperature is too low or too high according to site requirements 1. Check central heating or air conditioning in site. 2. Proceed according to the instructions provided below. FB10000 Error Message Troubleshooting WARNING! High Voltage System! Do not touch any wiring while system is UP! From this stage and on, only an HP certified electrician may perform the tests. Faulty cable connection from sensor to Control Module 1. Check cable connection from sensor to Control Module 2. Check Sensor wiring (short circuit) Faulty control module 1. If wiring is to B&R control module is OK, check Control module. 2. If B&R control module is faulty replace it. 2