HP Scitex FB10000 Geffen TS Error 66056 - Page 6

B&R module 1DO2 in LEC is faulty

Page 6 highlights

Error ID: 66056: Black cross valve front failed to close FB10000 Error Messages Troubleshooting B&R module 1DO2 in LEC is faulty Cable CX161-03230 connects J11 in the J1 in the bridge pneumatic panel located under the bridge in the rear side of the printer. This cable controls the air supply that opens and closes the 12 cross valves blocking the ink flow when the bridge is up. The air is distributed as described in the diagram on the right. Top Flowchart 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 66056: Black cross valve front failed to close
FB10000 Error Messages Troubleshooting
6
B&R module 1DO2 in LEC is faulty
Cable CX161-03230 connects J11 in the J1 in the bridge pneumatic panel located under the bridge in the rear
side of the printer.
This cable controls the air supply that opens and closes the 12 cross valves blocking the ink flow when the
bridge is up. The air is distributed as described in the diagram on the right.
Top
Flowchart