Error ID: 66055: Black cross valve front failed to close FB10000 Error Messages Troubleshooting FB10000 Error Messages Troubleshooting Error ID: 66055: Black cross valve front failed to close Error Severity: Critical Possible Causes • Cross valves sensors do not receive 24V supply • Feeding valve in Bridge Pneumatic panel does not supply air pressure to cross valves • Main Valve in Main Pneumatic panel does not supply air pressure to feeding valve in bridge pneumatic panel • One or more cross valve(s) are mechanically stuck • One or more cross valve sensor(s) is faulty • B&R module 1DO2 in LEC is faulty • One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty Troubleshooting Flowchart 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 66055: Black cross valve front failed to close
FB10000 Error Messages Troubleshooting
1
FB10000 Error Messages Troubleshooting
Error ID: 66055: Black cross valve front failed to close
Error Severity:
Critical
Possible Causes
Cross valves
sensors
do not receive 24V supply
Feeding valve in Bridge Pneumatic panel does not supply air pressure to cross valves
Main Valve in Main Pneumatic panel does not supply air pressure to feeding valve in bridge pneumatic panel
One or more cross valve(s) are mechanically stuck
One or more cross valve sensor(s) is faulty
B&R module 1DO2 in LEC is faulty
One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty
Troubleshooting Flowchart