The tolerance is, Release the screws on the table supports to allow inserting the shims.
View all HP Scitex FB7500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
The tolerance is 0.3mm on one meter and 0.6mm for the entire table. You must to try to minimize the results to minimum difference. 6. If the measurements are not in the tolerance, you need to add shims between the table and table supports (or X motor support/slider). 7. Release the screws on the table supports to allow inserting the shims. Bad Shims Good
The tolerance is
0.3mm
on one meter and
0.6mm
for the entire table. You must to
try to minimize the results to minimum difference.
6.
If the measurements are not in the tolerance, you need to add shims between the
table and table supports (or X motor support/slider).
7.
Release the screws on the table supports to allow inserting the shims.
Bad
Good
Shims