Table 11-2, Front-panel error messages

Page 96 highlights

Front-panel errors Table 11-2 Numerical error codes Error code Recommendation 14.2 Three-phase power is unexpectedly off. Call your service representative, and be prepared to answer questions about indicator lights and fuses. See HP Customer Care Centers on page 93. 14.3 The three-phase voltage is not set. Set it using the front panel. 14.5:12 Restart the printer. 14.8 Emergency stop button pushed. Release all four emergency stop buttons. Turn circuit breaker ACB-1 off and then on. 14.9 Fuse error. Turn off the printer (see the User's guide). Open the FH11 fuse holders and check the fuses. Replace any fuse if necessary. 15.1 The printer is unable to warm up to its working temperature. Check that the three-phase power supply is working. Check that the curing plates are horizontal. This problem can also be caused by holes in the substrate, by reflective or transparent substrates or by a dirty or faulty infrared sensor. 15.2 The printer is unable to cool down to its working temperature. Call your service representative. See HP Customer Care Centers on page 93. 16.1 The printer is unable to warm up to its working temperature. Check that the three-phase power supply is working. LX850 only: If the curing plates are horizontal, lower them. 16.2 The printer is unable to cool down to its working temperature. If the ambient temperature is within the normal range, this problem may be caused by removing the substrate too quickly after printing. Try leaving the substrate in the printer until temperatures settle down after printing. 41.1:03, 41.3:10, 41.4:03 Restart the printer. 44.1:03 Possible substrate jam. If there is really a substrate jam, see The substrate has jammed on page 49. Otherwise, restart the printer. 44.2:10, 44.3:10, 44.4:03 Restart the printer. 45.1:03 Possible substrate jam. If there is really a substrate jam, see The substrate has jammed on page 49. Otherwise, restart the printer. 45.2:10, 45.3:10, 45.4:03 Restart the printer. 46.1:01 There is a problem with the yellow/magenta printhead primer. See Maintain the printhead primers on page 35. 46.2:01 There is a problem with the light cyan/light magenta printhead primer. See Maintain the printhead primers on page 35. 46.3:01 There is a problem with the cyan/black printhead primer. See Maintain the printhead primers on page 35. 47.1:03 The printhead cleaning advance motor has failed to perfom the wiper advance movement as expected. The pinch module is not properly closed or the roll path is stuck, the roller can not move the substrate. 48.1.1 Carriage beam error. Restart the printer, then go to the front panel and select the Substrate Management icon, then Carriage beam position > Carriage system recovery. 48.1.3 Carriage beam error. Restart the printer. If the error persists, call your service representative (see HP Customer Care Centers on page 93). If no error is reported but there is still some problem with substrate advance, go to the front panel and select the Substrate Management icon, then Carriage beam position > Carriage system recovery. 90 Chapter 11 Front-panel error messages ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

Table 11-2
Numerical error codes
Error code
Recommendation
14.2
Three-phase power is unexpectedly off. Call your service representative, and be prepared to
answer questions about indicator lights and fuses. See
HP Customer Care Centers
on page
93
.
14.3
The three-phase voltage is not set. Set it using the front panel.
14.5:12
Restart the printer.
14.8
Emergency stop button pushed. Release all four emergency stop buttons. Turn circuit breaker
ACB-1 off and then on.
14.9
Fuse error. Turn off the printer (see the
User's guide
). Open the FH11 fuse holders and check
the fuses. Replace any fuse if necessary.
15.1
The printer is unable to warm up to its working temperature. Check that the three-phase power
supply is working. Check that the curing plates are horizontal. This problem can also be
caused by holes in the substrate, by reflective or transparent substrates or by a dirty or faulty
infrared sensor.
15.2
The printer is unable to cool down to its working temperature. Call your service representative.
See
HP Customer Care Centers
on page
93
.
16.1
The printer is unable to warm up to its working temperature. Check that the three-phase power
supply is working. LX850 only: If the curing plates are horizontal, lower them.
16.2
The printer is unable to cool down to its working temperature. If the ambient temperature is
within the normal range, this problem may be caused by removing the substrate too quickly
after printing. Try leaving the substrate in the printer until temperatures settle down after
printing.
41.1:03, 41.3:10, 41.4:03
Restart the printer.
44.1:03
Possible substrate jam. If there is really a substrate jam, see
The substrate has jammed
on page
49
. Otherwise, restart the printer.
44.2:10, 44.3:10, 44.4:03
Restart the printer.
45.1:03
Possible substrate jam. If there is really a substrate jam, see
The substrate has jammed
on page
49
. Otherwise, restart the printer.
45.2:10, 45.3:10, 45.4:03
Restart the printer.
46.1:01
There is a problem with the yellow/magenta printhead primer. See
Maintain the printhead
primers
on page
35
.
46.2:01
There is a problem with the light cyan/light magenta printhead primer. See
Maintain the
printhead primers
on page
35
.
46.3:01
There is a problem with the cyan/black printhead primer. See
Maintain the printhead primers
on page
35
.
47.1:03
The printhead cleaning advance motor has failed to perfom the wiper advance movement as
expected. The pinch module is not properly closed or the roll path is stuck, the roller can not
move the substrate.
48.1.1
Carriage beam error. Restart the printer, then go to the front panel and select the Substrate
Management icon, then
Carriage beam position
>
Carriage system recovery
.
48.1.3
Carriage beam error. Restart the printer. If the error persists, call your service representative
(see
HP Customer Care Centers
on page
93
). If no error is reported but there is still some
problem with substrate advance, go to the front panel and select the Substrate Management
icon, then
Carriage beam position
>
Carriage system recovery
.
90
Chapter 11
Front-panel error messages
ENWW
Front-panel errors