HP Server rp7405 Service Processor (GSP or MP) - User Guide, Second Edition - Page 22
On HP Superdome servers, the customer LAN port is labeled Customer LAN. On HP
View all HP Server rp7405 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
On HP Superdome servers, the customer LAN port is labeled "Customer LAN". On HP rp8400 servers, it is "GSP LAN". On HP rp7405/rp7410 servers, it is the only LAN connection on each core I/O board. • Private LAN for Service Processor (Superdome Only) The private LAN connects to the Superdome service support processor (SSP) workstation, also called the service management station (SMS). Only Superdome servers have a private LAN. Do not use the private LAN on the HP sx1000 chipset-based Superdome servers. To configure service processor network settings, you can use the LC command from the Command menu. To list the current service processor network configuration use the LS command. The following examples show service processor LAN status for several HP nPartition servers. Default Service Processor Network Settings Table 2-1 and Table 2-2 list the default customer LAN and private LAN network settings for nPartition servers. Only Superdome servers have a private LAN. Table 2-1 Default Configuration for Service Processor Customer LAN (All nPartition Servers) Customer LAN IP Address Customer LAN Host Name Customer LAN Subnet Mask Customer LAN Gateway 192.168.1.1 gsp0 255.255.255.0 192.168.1.1 Table 2-2 Default Configuration for Service Processor Private LAN (HP Superdome Servers Only) Private LAN IP Address Private LAN Host Name 192.168.2.10 priv-00 22 Using the Service Processor