timeout, DECRYPT_DECOMPRESS_TIMEOUT : Cmd 0x932b4000., Port Admin: Port Binding should disable
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
If second FDISC comes in before the switch responds to the first FDISC between the same pair of devices, the Access Gateway daemon Fixed in FOS 6.3.0 panics. In WebTools, for Add operation in VLAN in CEE tab, all created data Fixed in FOS 6.3.0 is not added in the table. FCAP works only in Non-VF mode or VF mode with Default Switch. Fixed in FOS 6.3.0 Unexpected software call traceback error messages are being displayed on the console. Fixed in FOS 6.3.0 DC SAN Director standby CP may reboot due to ASSERT - Failed expression: new_snode != NULL if the chassis have 6-port 10Gb FC ISL Fixed in FOS 6.3.0 blade. When the Ethernet connectivity goes down for about 5 seconds, an Encryption SAN Switch in an hacluster encounters a "VERIFY - Failed expression" and ffdc is generated. Fixed in FOS 6.3.0 Supportsave: USB: interactive mode stores all files illegally in switch root directory instead of the USB device. Fixed in FOS 6.3.0 Port Admin: Port Binding should disable 'Auto Mode' when the port is part of a 256 area type that does not support auto mode. Fixed in FOS 6.3.0 Data miscompare seen when the data is written using a KV key, and read using a cache key. Fixed in FOS 6.3.0 Workaround prior to code change: Disable the DEK cache and always use the key vault. Overnight run of HAfailover test in large fabric caused a panic on DC Fixed in FOS 6.3.0 SAN Director. QoS can be disabled on ports on 4Gb platforms, but then it cannot Fixed in FOS 6.3.0 later be reenabled to run QoS. Port Admin : Port Swap does not warn the user the ports will be disabled. Fixed in FOS 6.3.0 If switches in an edge fabric have the Principal Priority set to non-default values, updating firmware on the FCR switch may result in fabric reconfiguration and momentary traffic disruption. Fixed in FOS 6.3.0 Workaround prior to code change: Do not set the principal priority of switches in edge fabric to non default value in a routed MetaSANs. pending merge: fail to recover data with error: ERROR, SYS, FPGA timeout, DECRYPT_DECOMPRESS_TIMEOUT : Cmd 0x932b4000. Fixed in FOS 6.3.0 FICON XRC times out on 400 multiprotocol router to DC SAN Director. Fixed in FOS 6.3.0 Need more info in configuration upload/download process. Fixed in FOS 6.3.0 Sfpshow displays incorrect values for current, RX power, and TX power. Fixed in FOS 6.3.0 Workaround prior to code change: Toggle (enable / disable) all disabled ports in order to restart SFP polling. HP StorageWorks FOS 6.3.0b Release Notes 63