HP StorageWorks 2/16V HP StorageWorks SAN Switch rack mount kit installation i - Page 2

About the Plenum, Installation and safety guidelines

Page 2 highlights

About the Plenum The plenum is an air duct that attaches to the switch rails, enabling the switch to draw in cooler air from outside the rack instead of drawing in heated air from inside the rack. The plenum ships with the following switch models only: • SAN Switch 2/8V • SAN Switch 2/8 • SAN Switch 2/16V • 4/8 SAN Switch • 4/16 SAN Switch • 4/32B SAN Switch • 8/8 SAN Switch • 8/24 SAN Switch See "Installing the plenum (if required)" on page 6 for instructions on installing a plenum. Installation and safety guidelines Verify that the rack and the area surrounding the rack meet the following requirements: • Plan a rack space that is 1.5 units high (6.7 cm or 2.6 inches), 48.3 cm (19 inches) wide, and at least 68.6 cm (23 inches) deep. For the MP Router, 4/64 SAN Switch, 8/80 SAN Switch, and Encryption SAN Switch, plan a rack space that is at least 2 units high. • Ground all equipment in the rack through a reliable branch circuit connection, and maintain ground at all times. Do not rely on a secondary connection to a branch circuit, such as a power strip. • Ensure that airflow and temperature requirements are met on an ongoing basis. • Secure the rack to ensure stability in case of unexpected movement. Installing the SAN Switch Rack Mount Kit in an HP custom rack Use the SAN Switch Rack Mount Kit to install your HP device in the following HP custom racks: • HP System/e Rack • HP 10000 Series Rack For optimal cable management, HP recommends that you install the SAN Switch Rack Mount Kit to allow the nonport side of the device to slide out of the cool-air side of the rack. In this installation, the port side of the device is set back from the edge of the rack, allowing a more gradual bend in the fiber optic cables. NOTE: The SAN Switch Rack Mount Kit installation requires one technician. • #2 Phillips screwdriver • 7/16-inch wrench or socket • Plenum (if required) See "About the Plenum" on page 2 to determine if you need to install a plenum before rack mounting your device. • SAN Switch Rack Mount Kit hardware See Table 1, which identifies the rails and rail-mounting hardware. Depending upon your configuration, one of the following devices may be required: • SAN Switch or MP Router • FCoE Converged Network Switch • Encryption SAN Switch Table 1 SAN Switch Rack Mount Kit hardware Item Description Two rear mounting brackets A right inner rail and a right outer rail A left inner rail and a left outer rail 14 #8-32 x 3/16-inch Phillips panhead screws with thread lock for use with the SAN Switch 2/32 only. 14 #8-32 x 5/16-inch Phillips panhead SEMS screws for use with the 4/8, 4/16, 4/32, 4/64 SAN and 4/32B SAN Switches, and the 2/16, 2/ 8V, 2/16V, MP Router, 400 MP Router, 8/8, 8/24, 8/40, 8/80, and FCoE Converged Network Switch NOTE: All devices require 10 screws except for the 4/32B SAN Switch, MP Router, Encryption SAN Switch, and FCoE Converged Network Switch, which require only 6 screws. Ten #10-32 x 1/2-inch Phillips panhead screws with captive star lock washers The following items are required to install the device in a rack: • Power cables Eight #10 alignment washers Page 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

About the Plenum
The plenum is an air duct that attaches to the switch rails, enabling the
switch to draw in cooler air from outside the rack instead of drawing in
heated air from inside the rack.
The plenum ships with the following switch models only:
SAN Switch 2/8V
SAN Switch 2/8
SAN Switch 2/16V
4/8 SAN Switch
4/16 SAN Switch
4/32B SAN Switch
8/8 SAN Switch
8/24 SAN Switch
See “
Installing the plenum (if required)
” on page 6 for instructions on
installing a plenum.
Installation and safety guidelines
Verify that the rack and the area surrounding the rack meet the following
requirements:
Plan a rack space that is 1.5 units high (6.7 cm or 2.6 inches), 48.3
cm (19 inches) wide, and at least 68.6 cm (23 inches) deep. For the
MP Router, 4/64 SAN Switch, 8/80 SAN Switch, and Encryption
SAN Switch, plan a rack space that is at least 2 units high.
Ground all equipment in the rack through a reliable branch circuit
connection, and maintain ground at all times. Do not rely on a sec-
ondary connection to a branch circuit, such as a power strip.
Ensure that airflow and temperature requirements are met on an on-
going basis.
Secure the rack to ensure stability in case of unexpected movement.
Installing the SAN Switch Rack Mount Kit
in an HP custom rack
Use the SAN Switch Rack Mount Kit to install your HP device in the
following HP custom racks:
HP System/e Rack
HP 10000 Series Rack
For optimal cable management, HP recommends that you install the SAN
Switch Rack Mount Kit to allow the nonport side of the device to slide
out of the cool-air side of the rack. In this installation, the port side of
the device is set back from the edge of the rack, allowing a more gradual
bend in the fiber optic cables.
NOTE:
The SAN Switch Rack Mount Kit installation requires one
technician.
The following items are required to install the device in a rack:
Power cables
#2 Phillips screwdriver
7/16-inch wrench or socket
Plenum (if required)
See “
About the Plenum
” on page 2 to determine if you need to in-
stall a plenum before rack mounting your device.
SAN Switch Rack Mount Kit hardware
See
Table 1
, which identifies the rails and rail-mounting hardware.
Depending upon your configuration, one of the following devices may
be required:
SAN Switch or MP Router
FCoE Converged Network Switch
Encryption SAN Switch
Table 1 SAN Switch Rack Mount Kit hardware
Description
Item
Two rear mounting brackets
A right inner rail and a right
outer rail
A left inner rail and a left outer
rail
14 #8-32 x 3/16-inch Phillips
panhead screws with thread
lock for use with the SAN
Switch 2/32 only.
14 #8-32 x 5/16-inch Phillips
panhead SEMS screws for use
with the 4/8, 4/16, 4/32,
4/64 SAN and 4/32B SAN
Switches, and the 2/16, 2/
8V, 2/16V, MP Router, 400
MP Router, 8/8, 8/24, 8/40,
8/80, and FCoE Converged
Network Switch
NOTE:
All devices require 10
screws except for the
4/32B SAN Switch, MP
Router, Encryption SAN
Switch, and FCoE
Converged Network
Switch, which require
only 6 screws.
Ten #10-32 x 1/2-inch Phillips
panhead screws with captive
star lock washers
Eight #10 alignment washers
Page 2