HP StorageWorks 2/32 HP StorageWorks Fabric OS 4.4.0F Release Notes (AA-RW89A- - Page 30
Description, Default Threshold, Settings, Default Alarm, Threshold State
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Area Description Default Threshold Default Alarm Settings Settings Invalid Transmission Monitors the Word number of invalid words transmitted Unit: Errors Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-between: 0 Link Failure Count Monitors the number of link failures Unit: Errors Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-between: 0 Loss of Signal Count Monitors the number of signal loss errors Unit: Errors Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-between: 0 Primitive Sequence Protocol Errors Monitors the number of primitive sequence errors Unit: Errors Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-between: 0 Threshold State Informative Informative Out of range In range Informative Informative Out of range In range Informative Informative Out of range In range Informative Informative Out of range In range The following row replaces the existing row "Flash" in Table 28, "Resource Class Threshold Defaults," on page 98: Area Flash Description Default Threshold Default Alarm Settings Settings Monitors the percentage of compact flash used Unit: Percent (%) Time Base: none Low: 0 High: 85 Buffer: 0 Changed: 0 Below: 3 Above: 3 In-between: 1 Threshold State Informative Informative Out of range In range 30 HP StorageWorks Fabric OS 4.x Fabric Watch user guide, part number: AA-RVJ0A-TE