HP StorageWorks 2/64 HP StorageWorks Fabric OS 5.X Procedures User Guide (AA-R - Page 160
Table 29 Loopback modes, If the problem stops or goes away
View all HP StorageWorks 2/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
To troubleshoot a marginal link: 1. Issue the portErrShow command. For example: switch:admin> porterrshow frames enc crc too too bad enc disc link loss loss frjt fbsy tx rx in err shrt long eof out c3 fail sync sig sig 0: 22 24 0 0 0 0 0 1.5m 0 7 3 0 0 0 1: 22 24 0 0 0 0 0 1.2m 0 7 3 0 0 0 2: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4: 149m 99m 0 0 0 0 0 448 0 7 6 0 0 0 5: 149m 99m 0 0 0 0 0 395 0 7 6 0 0 0 6: 147m 99m 0 0 0 0 0 706 0 7 6 0 0 0 7: 150m 99m 0 0 0 0 0 160 0 7 5 0 0 0 8: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 12: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 13: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 14: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 15: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 32: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 33: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 34: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 35: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 36: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 37: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 38: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 39: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 40: 99m 146m 0 0 0 0 0 666 0 6 796 7 0 0 41: 99m 149m 0 0 0 0 0 15k 0 2 303 4 0 0 42: 99m 152m 0 0 0 0 0 665 0 2 221 5 0 0 43: 99m 147m 0 0 0 0 0 16k 0 2 144 4 0 0 44: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 45: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 46: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 47: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 switch:admin> 2. Establish whether there is a relatively high number of errors (such as CRC errors or ENC_OUT errors), or if there is a steadily increasing number of errors to confirm a marginal link. 3. If you suspect a marginal link, isolate the areas by moving the suspected marginal port cable to a different port on the switch. If the problem stops or goes away, the switch port or the SFP is marginal (proceed to step 4) If the problem does not stop or go away, proceed to step 7. 4. Replace the SFP on the marginal port. 5. Verify that you have an adapter to run the loopback test for the SFP. If you do not have an adapter, run the portLoopBack test on the marginal port using the loopback mode lb=5. See the HP StorageWorks Fabric OS 5.x command reference guide for additional information. Table 29 describes the loopback modes. Table 29 Loopback modes Mode Description 1 Port Loopback (loopback plugs) 2 External (SERDES) loopback 160 Troubleshooting