Recommended Action, Severity, SECLIB-SECVIOL_WSNMP, Message, Explanation
View all HP StorageWorks 2/8-EL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
SECLIB_System Error Messages Recommended Action Check the Security Connection Control Policy (SCC Policy specifies the WWNs of switches allowed in the fabric) to verify which switches are allowed in the fabric. If the switch is allowed in the fabric but is not included in the SCC policy, add the switch to the policy. If the switch is not allowed in the fabric, this is a valid violation message and an unauthorized entity is trying to access the fabric. Appropriate action should be taken as specified by your enterprise security policy. Severity Informational SECLIB-SECVIOL_WSNMP Message Info SECLIB-SECVIOL_WSNMP, 4, Security violation: Unauthorized host with IP address tries to do SNMP write operation. Explanation A security violation was reported. The specified unauthorized host attempted to perform a write SNMP operation (WSNMP). Recommended Action Check the WSNMP policy and verify which hosts are allowed access to the fabric through SNMP. If the host is allowed access to the fabric but is not included in the policy, add the host to the policy. If the host is not allowed access to the fabric, this is a valid violation message and an unauthorized entity is trying to access the fabric. Appropriate action should be taken as specified by your enterprise security policy. Severity Informational Diagnostic and System Error Messages Version 3.1.x Reference Guide 99