HP StorageWorks 2000fc HP StorageWorks 2000 G2 Modular Smart Array reference g - Page 103
Examine the FRU specified in the message to, specific event indicating a problem.
View all HP StorageWorks 2000fc manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
Table 14 Event code descriptions and recommended actions (continued) Event Event type Description code Recommended action 306 Informational An old serial number in SC flash memory has been updated to a new serial number. 307 Critical A temperature sensor on a controller FRU detected an over-temperature condition that caused the controller to shut down. Check that the storage system's fans are running. Check that the ambient temperature is not too warm. The enclosure operating range is 41-104° F (5-40° C). Check for any obstructions to the airflow. If none of the above explanations apply, replace the controller FRU that reported the error. 308 Informational The default host port speed has changed from 4 Gbit/sec to 2 Gbit/sec because the controller module's HIM has a Broadcom PBC. 309 Informational Normally when the MC is started, the IP data is obtained from the SEEPROM where it is persisted. If the system is unable to write it to the SEEPROM the last time it changed, a flag is set in flash memory. This flag is set during startup, and if set, this event is logged and the IP data that is in flash memory is used. The only time that this would not be the correct IP data would be if the controller board was swapped and then whatever data is on the board's flash memory is used. 310 Informational After a rescan, the controller completed back-end discovery and initialization of enclosure data. 313 Critical An I/O module is down and will not be automatically restarted. This only applies when the other SC goes down. The SC needs service or replacement. 314 Critical A FRU has failed or is not operating correctly. This event follows some other FRU specific event indicating a problem. Examine the FRU specified in the message to determine whether it needs to be replaced. 315 Critical The controller module is incompatible with the enclosure. The controller will automatically shut down. If two incompatible controllers are inserted at the same time, or booted at the same time, one controller will crash and the other will hang. This behavior is expected and prevents data loss. Move the controller module to a compatible controller. 316 Informational The temporary license for a feature is about To continue using the feature after the trial or warning to expire or has expired. This event is logged period, purchase a permanent license. as informational while time remaining in the trial period is nonzero. This event is logged as a warning when the trial period expires. HP StorageWorks 2000 G2 Modular Smart Array Reference Guide 103