HP StorageWorks 2000i HP StorageWorks 2000 G2 Modular Smart Array reference gu - Page 104
down disk., health and status FTDN fault tolerant with
View all HP StorageWorks 2000i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 104 highlights
Table 14 Event code descriptions and recommended actions (continued) Event Event type Description code Recommended action 322 Warning The controller has an older SC version than the version used to create the CHAP authentication database in the controller's flash memory. The CHAP database cannot be read or updated. However, new records can be added, which will replace the existing database with a new database using the latest known version number. Upgrade to an SC version that is current for the indicated database version. • If no records were added, the database becomes accessible and remains intact. • If records were added, the database becomes accessible but contains only the new records. 352 Informational EC assert data or stack-dump data is accessible. 353 Informational EC assert data and stack-dump data have been cleared. 354 Informational SAS topology has changed on a host port. or warning For example, the SAS cable connecting a controller host port to a host has been disconnected. This event is logged as informational for a topology change where at least one PHY goes "up." This event is logged as a warning for a topology change where at least one PHY goes "down." 355 Warning The faceplate's debug button was found to be stuck in the On position during boot up. 412 Warning One disk in the specified RAID-6 vdisk failed. The vdisk is operational with Degraded health and status FTDN (fault tolerant with a down disk). Replace the down disk with a spare so the system can start reconstructing the vdisk. 443 Warning A firmware version mismatch has been detected in an MSA70 drive enclosure. The enclosure should be updated to the latest supported version of firmware as soon as possible. In the drive enclosure all FRUs (I/O module, fan, power supply, midplane, backplane, and 7-segment LED) must be at a combined proper firmware recipe. The two I/O modules must be at equal firmware versions. Any replaced MSA70 FRUs might have older firmware that does not match an internally defined recipe. Update the drive enclosure to the latest firmware version to ensure all FRUs are at the proper firmware level. 104 Event code reference