HP StorageWorks 2000i HP StorageWorks MSA2000 G2 Firmware Release Notes (50884 - Page 4
Fixes, Fixed an issue where media errors were not leading to a disk drive being removed from service. - manual
View all HP StorageWorks 2000i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
• Improved ability to communicate with a controller after it has been shut down, to improve restart behavior. • Enhanced the SNMP community string to support strings that contain dash and underscore characters. • Improved the SNMP Notification page in internationalized systems that uses non-ASCI characters, such as Japanese. Fixes • Fixed a problem detecting the number of disk drive bays in an expansion enclosure. • Fixed the issue that all drives spun up concurrently when a single power supply was in use. If only a single power supply is functioning, disk drives now spin up in a staggered manner. • Fixed a situation where a SATA disk drive may be dropped from a vdisk during a firmware up- grade. • Fixed a problem where user credentials were reset to default values when controller A was replaced. • Fixed an issue where the vdisk number was mis-reported. • Fixed an issue where a firmware upgrade did not error out when an invalid package was used. • Fixed an issue that allowed a user to set the independent cache mode to an unsupported config- uration. • Fixed an issue that a reconstructing vdisk would report as completed when just beginning the re- build. • Fixed an issue where a failed disk drive might cause a controller to stall. • Fixed an issue where correctable ECC errors caused a scrub failure. • Fixed a problem where a scrub error was reported when, in fact, the background scrub was manually stopped. • Fixed an issue where an offline vdisk might not be appropriately quarantined when an array is powered up. • Fixed an issue where the array did not correctly report all supported persistent reservation types. • Fixed an issue where deleting a vdisk failed. • Fixed an issue that, while deleting a snapshot, could lead to an error and cause the snapshot to not be deleted. • Fixed an issue where a quarantine event caused a scrub error. • Fixed an issue where media errors were not leading to a disk drive being removed from service. • Fixed a situation where IO requests during a failover would fail out with the following error message: "Request not supported". • Fixed a problem where failover did not occur, even when a component failed. • Fixed a situation where reconstruction progress stuck at 0%. • Fixed a rare timing issue that lead to a drive enclosure not being discovered on a reboot. • Fixed an issue that lead to drive enclosure firmware update failure. • Fixed a problem where a LUN reset did not clear same sector reads. • Fixed an issue where a controller failover lead to IP settings being lost. • Fixed an issue where a Windows OS might see a volume that does not exist at LUN 0. • Fixed an issue where both storage controllers became unresponsive when a disk issue caused a general protection fault to be delivered to both controllers. • Fixed an issue that could cause a storage controller to crash while I/O is being written to a RAID 6 vdisk that is in a critical state. • Fixed a timing issue that lead to a controller becoming unresponsive. 4