HP StorageWorks 2000i HP StorageWorks MSA2000 Family MPIO DSM installation gui - Page 19
weight, is the assigned weight.
View all HP StorageWorks 2000i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Example In the following example, before executing the command, primary 02010104, Primary is shown as false; after running the command, Primary is shown as true. dsmcli> primary 02010104 dsmcli> pathinfo Policy: SerialNumber: PathId: Weight: Primary: ScsiAddress: HbaWWPN: CtrlPortWWPN: State: BytesRead: BytesWritten: NumberReads: NumberWrites: FailOver EB3FDE12-01 02010104 0 true 02000104 10000000C92F464E 217000C0FF0A4052 Online 193536 1871360 93 1752 weight The weight command sets the weight of the specified path. I/O is sent to the path with the lowest weight. If that path fails, I/O is sent to the path with the next lowest weight, and so on. weight pathID weight where pathID is the specified path ID and weight is the assigned weight. The recommended weight range is 0-100. Note - The weight command is valid only when the weighted load balance policy is available (see "policies" on page 17 for the list of currently supported load balance policies). Installing the MPIO DSM 19