HP StorageWorks 2000sa HP StorageWorks 2000 G2 Modular Smart Array reference g - Page 90
Event code descriptions and recommended actions continued, Table 14
View all HP StorageWorks 2000sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
Table 14 Event code descriptions and recommended actions (continued) Event Event type Description code Recommended action 19 Informational A rescan has completed. 20 Informational A firmware update has completed. 21 Informational Vdisk verification has completed. This event or warning is logged as informational if the command fails immediately, succeeds, or is aborted by the user; or a warning if the operation fails during verification. 23 Informational Vdisk creation has started. 24 Informational The assigned LUN for this volume has changed. 25 Informational The statistics for the specified vdisk have been reset. 27 Informational Cache parameters have been changed for the specified vdisk. 28 Informational Controller parameters have been changed. This event is logged when general configuration changes are made; for example, utility priority, remote notification settings, user interface passwords, and management port IP values. This event is not logged when changes are made to vdisk or volume configuration. 31 Informational A global or vdisk spare was deleted. 32 Informational Vdisk verification has started. 33 Informational Controller time/date has been changed. This event is logged before the change happens so the event timestamp shows the "old" time. 34 Informational Controller has been restored to factory defaults. For an FC controller, restart it to make the default loop ID take effect. 37 Informational Vdisk reconstruction has started. 39 Warning The sensors monitored a temperature or voltage in the warning range. • Check that the storage system's fans are running. • Check that the ambient temperature is not too warm. The enclosure operating range is 41-104° F (5-40° C). • Check for any obstructions to the airflow. • If none of the above explanations apply, replace the controller FRU that reported the error. When the problem is fixed, event 47 is logged. 90 Event code reference