HP StorageWorks 4/256 HP StorageWorks Fabric OS 5.2.1b Release Notes (AA-RWEYC - Page 17
Web Tools columns like Name, State, Reason, etc., from Fabric Watch
View all HP StorageWorks 4/256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
When using SMIAgent to connect to a switch in a larger fabric that contains more than 383 FDMI devices, the LoginAsUser fails and the switch panics; it either reboots or does HAfailover depending on platform. Fixed per Fabric OS 5.2.1. Removing a switch from a fabric causes trace files on remote switches to generate error message. Only applies to switches running 5.2.0x. Fixed per Fabric OS 5.2.1. Switch panics with remote procedure call daemon (rpcd) during process link incident record (LIRR), due to improperly initializing data structure. Fixed per Fabric OS 5.2.1. Registration to storage array by storage management agent fails with CRC error on FC side when write data not 4-byte aligned. Fixed per Fabric OS 5.2.1. After upgrade to Fabric OS 5.0.5x, dual CP switches show excessive TRCK-1004 logs, though no change to the configuration. Fixed per Fabric OS 5.2.1. After connecting MPR 400 to native mode switch fabric with large zone DB, FCR daemon panicked. Only applies to switches running 5.2.0x. Fixed per Fabric OS 5.2.1. Name Server daemon crash and switch panic after failed attempt to enable large zone configuration (D,P format). Fixed per Fabric OS 5.2.1. swAgtCmtyTable shows no entries when queried through SNMPv3 client, but does show entries when queried through SNMPv1. Fixed per Fabric OS 5.2.1. Switch error exception when trying to getInstance of NodeFCPort of FDMI enabled HBA attached to v3.2/v4.4.0d switch, when Fabric OS Fixed per Fabric OS 5.2.1. 4.4.0d or 5.0.1 switch is proxy. When log display contains many messages, the window size covers most of the Web Tools display. No functional impact. Fixed per Fabric OS 5.2.1. Java console will report a Null Pointer Exception under rare circumstances when clicked on SFP, Loop tabs under port information tab. Switch operations unaffected. Fixed per Fabric OS 5.2.1. Using third party chassis management software to Restore Factory Defaults can result in loss of telnet connectivity. Fixed per Fabric OS 5.2.1. Internal ports on embedded switches are erroneously shown as having SFPs with Fabric Watch. Fixed per Fabric OS 5.2.1. FCIP diag fails if external link goes offline/online during POST. Fixed per Fabric OS 5.2.1. Host in one edge fabric fails to see targets in another edge fabric when routing policy changed from exchange based to port based in the backbone (4/256). Fixed per Fabric OS 5.2.1. FC side of the throughput on FR4-18i does not increase at expected ratio when GE compression enabled. Fixed per Fabric OS 5.2.1. Portshow not displaying IPIF present in configDB for GE1 of MPR 400. After using portcfg to configure the port, cannot configure IPIF. Fixed per Fabric OS 5.2.1. Gets error IP address already configured on Port ge1. During interop testing, ex_ports status does not change after enabling them from Web Tools. Fixed per Fabric OS 5.2.1. Web Tools columns like Name, State, Reason, etc., from Fabric Watch tree (port class) are restored mistakenly after auto refresh. Fixed per Fabric OS 5.2.1. CAM entries on shared port should set up in conjunction with zoning on existing AD, but are all the same across ADs. Fixed per Fabric OS 5.2.1. Web Tools Events show wrong date after time zone is changed, until switch is rebooted. Fixed per Fabric OS 5.2.1. Core files should be automatically deleted after supportsave command is invoked, but are left on the switch. Fixed per Fabric OS 5.2.1. HP StorageWorks Fabric OS 5.2.1b release notes 17