HP StorageWorks 4/64 Brocade Fabric OS Message Reference - Supporting Fabric O - Page 126
EM-1029, Message, Probable Cause, Recommended, Action, Severity, slotShow, errDump
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 126 highlights
11 EM-1029 EM-1029 Message , [EM-1029], ,, WARNING, , , a problem occurred accessing a device on the I2C bus (). Operational status () not changed, access is being retried. Probable Cause Indicates that the I2C bus had problems and a timeout occurred. Recommended Action This is often a transient error. Watch for the EM-1048 message, which indicates that the problem has been resolved. If the error persists, check for loose or dirty connections. Remove all dust and debris prior to reseating the field-replaceable unit (FRU). If it continues to fail, replace the FRU. Severity WARNING EM-1031 Message , [EM-1031], ,, ERROR, , ejector not closed. Probable Cause Indicates that the environmental monitor (EM) has found a switch blade that is inserted, but the ejector switch is not closed. The blade in the specified slot is treated as not inserted. Recommended Action Close the ejector switch (raise the slider in most blades, or completely screw in the upper thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades. Severity ERROR EM-1033 Message , [EM-1033], ,, ERROR, , CP in set to faulty because CP ERROR asserted Probable Cause Indicates that the standby control processor (CP) has been detected as faulty. The High Availability (HA) feature will not be available. This message occurs every time the other CP reboots, even as part of a clean warm failover. In most situations, this message is followed by the EM-1047 message, and no action is required for the CP; however, you might want to find out why the failover occurred. Recommended Action If the standby CP was just rebooted, wait for the error to clear (run slotShow to determine if it has cleared). Watch for the EM-1047 message to verify that this error has cleared. If the standby CP continues to be faulty or if it was not intentionally rebooted, check the error logs on the other CP (using the errDump command) to determine the cause of the error state. Try reseating the field-replaceable unit (FRU). If the message persists, replace the FRU. Severity ERROR 78 Fabric OS Message Reference 53-1000437-01