HP StorageWorks 4/64 Brocade Web Tools Administrator's Guide v6.3.0 (53-100134
HP StorageWorks 4/64 - SAN Switch Manual
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 4/64 manual content summary:
- HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 1
53-1001343-01 ® 28 July 2009 Web Tools Administrator's Guide Supporting Fabric OS v6.3.0 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 2
any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make brocade.com/support/oscd. Brocade Communications Systems, Incorporated Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 3
tunnels. Updates for Fabric OS v5.2.0 and the FC4-16IP blade. Also new security for Web Tools, including Role-Based Access Control and administrative domains. September 2006 Updates to reflect interface enhancements, support for new switch types, IPv6 support, and other enhancements. June 2007 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 4
2008 Updates to add support for Brocade Encryption Switch and FS8-18 Encryption Blade. August 2008 Updates to add support for Virtual Fabrics, IPSec, and consistency with DCFM. November 2008 Updates to add support for Brocade 7800 Extension Switch, Brocade 8000, FCOE10-24 DCX Blade, and FX8-24 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 5
chapter xxv How this document is organized xxv Supported hardware and software xxvi What's new in xxix Notice to the reader xxix Additional information xxix Brocade resources xxix Other industry resources xxx Getting technical Logging out 16 Web Tools Administrator's Guide v 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 6
or disabling a blade 45 Setting a slot-level IP address 46 Viewing IP addresses 46 Switch configuration 47 Enabling and disabling a switch 47 Changing the switch name 47 Changing the switch domain ID 47 Viewing and printing a switch report 48 vi Web Tools Administrator's Guide 53-1001343 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 7
arbitrated loop parameters 51 Configuring system services 52 Configuring signed firmware 52 Licensed feature management 52 Activating a license on a switch 53 Assigning slots for a license key 54 Removing a license from a switch 54 Universal time based licensing 55 High Availability overview - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 8
window 88 Creating and populating domains 89 Creating an Admin Domain 89 Adding ports or switches to the fabric 91 Activating or deactivating an Admin Domain 92 Modifying Admin Domain members 92 106 Enabling and disabling NPIV ports 106 viii Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 9
swapping 110 Determining if a port index was swapped with another switch port 110 Configuring BB credits on an F_Port 111 Enabling ISL SID-DID Performance Graphs 127 Creating a SCSI vs. IP Traffic Graph 129 Creating SCSI command graphs 129 Tunnel Administrator's Guide ix 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 10
136 Zoning configurations 137 Opening the Zone Administration window 137 Setting the default zoning mode 137 Zoning management 137 Refreshing fabric information 139 Refreshing Zone Working With Diagnostic Features In this chapter 155 x Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 11
the power supply status 159 Checking the physical health of a switch 160 Port LED interpretation 162 Port icon colors 163 LED representations 163 Brocade 48000 Director LEDs 164 Using the FC-FC Routing Service In this chapter 165 Fibre Channel Routing overview 165 Supported switches for - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 12
E-mail notification 196 Configuring the e-mail server on a switch 196 Configuring the e-mail alert 196 Administering Extended Fabrics In Administering the iSCSI Target Gateway In this chapter 203 iSCSI service overview 203 Supported platforms for iSCSI 204 Common iSCSI Target Gateway Admin - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 13
16 Chapter 17 Setting up iSCSI Target Gateway Services 206 Launching the iSCSI Target Gateway Admin Module 206 Launching the iSCSI setup wizard 208 Activating the iSCSI feature 208 Encryption Services for the iSCSI Gateway 208 Configuring the IP interface 209 Editing an IP Troubleshooting - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 14
switch service 253 Modifying Active Directory service 254 Removing Active Directory service 254 IPSec Concepts 255 Transport mode and tunnel mode 256 IPSec header options 257 Basic IPSec configurations 258 Internet Key Exchange (IKE) Concepts 259 xiv Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 15
IPSec transform policy 269 Adding an IPSec selector 272 Manually creating an SA 274 Editing an IKE or IPSec CUP fabrics overview 279 Enabling port-based routing 280 Enabling or disabling 292 Port information that is unique to FCoE 292 Switch Administration panel tab for FC0E 293 The CEE tab - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 16
Chapter 20 Index Quality of Service (QoS) configuration 298 Adding a CEE map 298 Adding a traffic and disabling a LAG 323 Enabling and disabling LLDP 324 Enabling and disabling QoS priority-based flow control 324 Enabling and disabling FCoE ports 324 Limitations In this chapter 327 General - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 17
Figure 16 Figure Switch Explorer 34 Switch Administration window, Switch tab 40 Network tab 42 Netstat Performance 43 Blade Default logical switch 66 Logical switch selector 66 Logical switch, fabric ID 2 67 Logical port properties 68 Upload/Download tab 70 Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 18
44 Figure 45 Figure 46 Figure 47 Figure 48 Figure 49 Figure 50 Figure 51 Figure 52 Figure 60 Figure 61 Figure 62 Figure 63 Figure 64 Figure 65 Figure 66 Figure 67 Figure 68 Figure click options 75 Firmware Download tab 76 Firmware Download tab for bladed switches 78 Configure Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 19
Power Status window 160 Figure 81 Switch Report window 161 Figure 82 Switch Report Action menu 162 Figure 83 Port and LED status color-coded information in the Port icon in Switch View . 163 Figure 84 Port LEDs for the FC4-32 port blade in the Brocade IP Interface dialog box 210 Figure 110 Add IP - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 20
Service drop-down menu 250 Figure 132 AAA Service tab 251 Figure 133 Transport mode and tunnel mode comparison 256 box 273 Figure 147 Add Manual-SA dialog box 274 Figure Switch RNID Information 289 Figure 154 Switch Administration panel with CEE tab 293 Figure 155 Switch Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 21
Figure 185 CEE Advanced Performance Statistics 322 Figure 186 CEE Error Detail Statistics 322 Figure 187 FCoE Edit Configuration dialog box 325 Web Tools Administrator's Guide xxi 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 22
xxii Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 23
Table 15 Table 16 Table 17 Supported port types for Brocade switches 122 Zoning features supported in DCFM Professional and Enterprise Edition . . . . 135 QoS zone name prefixes 136 Alarm notification table fields 195 Long-distance settings and license requirements 201 iSCSI gateway services - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 24
xxiv Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 25
Supported and installation instructions. • Chapter Switches," provides information on how to manage your fabric and switches using the Web Tools interface. • Chapter 4, "Maintaining Configurations and Firmware the Brocade Brocade Advanced Zoning feature to partition your storage area network (SAN - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 26
procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for 6.3.0, documenting all - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 27
Blade - FC8-16 port blade - FC8-32 port blade - FC8-48 port blade - FC10-6 port blade - FR4-18i router blade - FX8-24 DCX Extension Blade (new) • Brocade 48000 director - FA4-18 Fibre Channel application blade - FC4-16 port blade - FC4-16IP - FC4-32 port blade - FC4-48 port blade - FC10-6 port blade - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 28
Brocade Encryption Switch • Added Access Gateway auto rebalancing and manual rebalancing options • Added slot based licensing and universal time based licensing • Added support , command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 29
you or cause damage to hardware, firmware, software, or data. DANGER A Brocade and Fibre Channel, see the Brocade Glossary. For definitions of SAN- Brocade and industry-specific documentation that you might find helpful. Brocade resources To get up-to-the-minute information, go to http://my.brocade - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 30
the switch or fabric behavior immediately following the problem, and specific questions • Description of any troubleshooting steps already performed and the results • Serial console and Telnet session logs • syslog message logs 2. Switch Serial Number xxx Web Tools Administrator's Guide 53 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 31
Brocade 300, 4100, 4900, 5100, 5300, 7500, 7800, 8000, and Brocade Encryption Switch-On the switch switch • Brocade 7600-On the bottom of the chassis • Brocade 48000-Inside the chassis next to the power supply bays • Brocade DCX-On the bottom right on the port side of the chassis • Brocade @brocade. - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 32
xxxii Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 33
7 •Java plug-in configuration 8 •Value line licenses 10 •Opening Web Tools 11 •Role-Based Access Control 16 •Session management 17 •Requirements for IPv6 support 18 Web Tools overview Brocade Web Tools is an embedded graphical user interface (GUI) that enables administrators to monitor and - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 34
Active Directory support yes yes AD Context Switching no yes AD filtered views yes yes Admin Domain Management no yes AG Management yes yes Analyze zone config no no Basic Zoning and TI Zoning yes yes Blade High Availability yes yes IP Sec Policies no yes - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 35
tab yes yes Switch Status yes yes Switch View right-click options yes yes Trace dump yes yes USB Management yes yes User Management yes yes Verify and trouble shoot accessibility no all devices are selected. Monitor > Logs > Events Web Tools Administrator's Guide 3 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 36
> FCIP Tunnel tab Viewing FCIP tunnels is still supported in Web Tools 6.1.1, but New, Edit Config, on your workstation, verify that your switches and workstation meet the Web Tools and Java Plug-in 1.6.0_13 or later. Brocade has certified and tested Web Tools on the Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 37
10 (SPARC only) Firefox 2.0 Firefox 2.0 TABLE 4 Supported platforms Operating System Linux RedHat AS 3.0 Linux RedHat AS minimum of 256 MB of RAM for fabrics comprising up to 15 switches, 512 MB of RAM for fabrics comprising more than 15 switches, and Tools Administrator's Guide 5 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 38
Settings dialog box 3. Click Delete Files to remove the temporary files used by Java applications. 4. Click OK on the confirmation dialog box. 6 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 39
: • Internet Explorer might prompt for an upgrade, depending on the existing Java Plug-in version Brocade web site and is subject to change without notice. 2. Select JRE 5.0 Update 13. 3. Follow the instructions patchpage NOTE This URL points to a non-Brocade Web site and is subject to change without - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 40
13. Web Tools guides you through the steps to download the proper Java Plug-in. Java plug-in configuration If you are managing fabrics with more than 10 switches or 1000 ports, or if you are using the iSCSI Gateway module extensively, you should increase the default heap size to 256 MB to avoid - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 41
heap size: -Xms256m -Xmx256m In this example, the minimum and maximum sizes are both 256 MB. 5. Click Apply to apply your settings and close the Java Control Panel. 2. Click the Advanced tab and expand the Default Java for browsers option. Web Tools Administrator's Guide 9 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 42
supported switch switches in the fabric that have lower or higher firmware versions. It is important to note that when accessing these switches you are opening the remote switch's version of Web Tools, and the functionality available for those switches might vary. 10 Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 43
OS 6.3.0, refer to Table 3. Web Tools supports both HTTP and HTTPS protocol. Use the following procedure to open . 1. Open the Web browser and type the IP address of the device in the Address field: setup procedure for smaller switches. Refer to EZSwitchSetup Administrator's Guide for information about - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 44
in before you can view or modify any switch information. This section describes the login process. switch), which you must accept before logging in. The security banner displays every time you access the switch NOTE You must log in before you can view Switch Explorer (shown in Figure 6 on page 12). - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 45
• Brocade 5100 Use the following procedure to log in to a Virtual Fabric. 1. Select Options to display the Virtual Fabric options. You are given a choice between Home Logical Fabric and User Specified Virtual Fabric (Figure 9). Home Logical Fabric is the default. Web Tools Administrator's Guide 13 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 46
If you are logging in to a platform that is capable of supporting Admin Domains, the log in dialog box provides the option of logging select an Admin Domain other than your default home domain. You are given a choice of Home Domain (the default), or User Specified Domain. 2. Log Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 47
can choose a valid Admin Domain or click Cancel to log in to your home domain. FIGURE 11 Invalid Admin Domain dialog box Web Tools Administrator's Guide 15 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 48
firmware download from the Web Tools Switch Administration window. In this case, you are logged out a few minutes later when the switch restarts. • Your session times out. Role-Based Access Control Role-Based "User-defined accounts" on page 229. 16 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 49
-right corner of Switch Explorer window to close it. • Close all open Web Tools windows. NOTE If you click Logout in Switch Explorer, and Web Tools leaves the Temperature, Fan, Power, and the Switch status windows open, you must manually close them. Web Tools Administrator's Guide 17 53-1001343 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 50
support: • In a pure IPv6 environment, you must configure DNS maps to the IPv6 address of the switch. • The switch switch. • Use a switch with v5.3.0 or later firmware to manage a mixed fabric of IPv4 and IPv6 switches. • Switches running on version 5.2.0 do not discover IPv6 address-only switches - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 51
troubleshooting 37 Viewing Switch Explorer The first thing you see when you log in to a switch with Web Tools is Switch Explorer, shown in Figure 12 on page 21. Switch the switches switch switch Brocade DCX and DCX-4S enterprise-class platforms, the Encryption Switch, the 300, 5100, and 5300 switches - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 52
the Switch Event tab displays the switch. When you log out of Web Tools, it remembers the last window settings the next time you log in to the application. If you display the switch, the next time you log into Web Tools, by default Switch View will appear. 20 Web Tools Administrator's Guide 53 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 53
the areas of Switch Explorer. 1 Tasks and Fabric Tree 2 Menu bar 3 Switch View buttons 4 Changing the Virtual Fabric ID, or Changing the Admin Domain 5 Switch Events and Switch Information 6 Indicator bar 7 Professional Management Tool offering 8 Switch View Web Tools Administrator's Guide 21 53 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 54
icons are changed to be consistent with DCFM. Table 5 summarizes these changes. TABLE 5 Icon image changes Image Name Old Image New Image Switch Director or DCX Fabric Fabric segment Admin port Generic port Zone Zone Admin Zone config Zone folder Status button - Healthy Status button - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 55
TABLE 5 Icon image changes (Continued) Image Name Old Image New Image Switch event - Fatal Switch event - Informational Switch event - Warning Refresh Enable Disable Prohibit Viewing Switch Explorer 2 Web Tools Administrator's Guide 23 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 56
management" on page 137 for more information. • Switch administration • Port administration • Admin Domain administration • FCR (present only on the base switch when the Virtual Fabrics capability is enabled. • iSCSI administration • Fabric Watch 24 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 57
cursor over a switch to display the IP address and current status. To manually refresh the status of a switch within the fabric, right-click the switch in the Fabric Tree and choose Refresh. Although Fabric Tree displays all the switches in the fabric, you can manage switches that support 6.1 and - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 58
2 Viewing Switch Explorer FIGURE 14 Missing EGM license If you are logged into Web Tools After you log in, all the Admin Domains assigned to you are available in the drop-down menu (Figure 16). For most administrative tasks, you must be in either AD0 or the physical fabric. FIGURE 15 Login dialog - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 59
Switch Explorer 2 Figure 16 shows the Admin Domain context drop-down menu highlighted for changing the Admin Domain context. FIGURE 16 2. Click OK in the confirmation window. Switch Explorer refreshes to display the new Admin action and return to Switch Explorer. NOTE The Telnet window and - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 60
or disable beaconing and to view the status of beaconing from the button's icon. • Legend - click the button to view the legend for the Switch View. NOTE For all status displays based on errors per time interval, any errors cause the status to show faulty until the entire sample interval has passed - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 61
Viewing Switch Explorer 2 Blade representations Blades are graphically represented as shown in table. They are vertical in the DCX, and horizontal in the DCX-4s. TABLE 6 Blade representations Blade Graphic CORE8 CP8 FC8-48 FC8-32 FC8-16 FS8-18 FR4-18i FA4-18 FC10-6 FX8-24 FCOE10-24 Web - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 62
Switch View match the LEDs on the physical switch; however, the blink rate of the LEDs in the Switch -click a port in Switch View to get a the EGM license on the switch; otherwise access to these physically present on the switch, these ports are Brocade DCX, the Port Admin view is - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 63
port storage management NOTE Left-click the USB port on the switch to launch the USB Storage Management window. Switch View refresh rates The Switch View display is refreshed at 15 second intervals. However, the on the host system you are using. Web Tools Administrator's Guide 31 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 64
: - Base Switch Indicates whether or not the logical switch can act as a base switch. - Default Switch Indicates whether or not the logical switch is the default logical switch. - Allow serial number of the supplier. Displays the license ID. 32 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 65
license to manage groups of switches, download firmware, manage security settings, and deploy configurations across groups of switches. Contact your preferred storage bottom of the Switch Explorer. FIGURE 18 Professional Management tool offering Web Tools Administrator's Guide 33 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 66
switch. In Switch View, you can rest the cursor over a blade to view the blade ID and its status. It is easier to use the top of the blade to display the tool tip so that you do not inadvertently display the port tool tips. Firmware versions and IP 34 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 67
• Retrieval time increases when you are in a large fabric because there is more data to retrieve from the switches. • Processor speed of the system you are using may slow down the refresh rate. • OS-Job Scheduling have direct access to the fabric. Web Tools Administrator's Guide 35 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 68
switch is displayed in Switch View. Additional switch information is displayed in the Switch Events and Switch the Switch Administration switches and directors running different versions of firmware, use the switches or directors with the latest firmware versions to control the fabric. • If switches - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 69
to a CP blade on a director switch through a Telnet or SSH client window opened from Web Tools, even when the blade has an IP address and supports Telnet sessions. Refer to the Fabric OS Command Reference for information about the Telnet commands. NOTE Internet Explorer 7.0 default settings disable - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 70
2 Collecting logs for troubleshooting 38 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 71
IP address 43 •Removing a syslog IP address 44 •Setting up IP Filtering 44 •Blade management 45 •Switch configuration 47 •Switch restart 48 locating a switch using beaconing 63 •Locating logical switches using chassis beaconing 64 •Virtual Fabrics overview 65 Fabric and switch management - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 72
the Switch Administration window to the switch, click Apply before closing the module or before switching to another tab. The License tab, Firmware basic Switch Administration window procedures that are useful for many switch management operations. 40 Web Tools Administrator's Guide 53-1001343- - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 73
Switch Administration window. To open the Switch Administration window, do the following. 1. Click Switch Admin in the Manage section of the Tasks menu. The Switch the tabs and options. Refreshing the Switch Administration window You can refresh the the Switch Administration window, - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 74
. The IPFC address is set to FC0 for switches that do not support Virtual Fabrics. 1. Click the Network tab. FIGURE 21 Network tab 2. In the appropriate IP address section, enter the IP address you want to use for the IP interface. Use the IPv4 Address section or the IPv6 Address section to specify - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 75
refreshed based on the configured time interval. Configuring a syslog IP address The syslog IP represents the IP IP addresses are configured, the switch forwards all error log entries to the syslog on the specified servers. Up to six servers are supported. Refer to Fabric OS Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 76
IP address is displayed in the Syslog IP area. 5. Click Apply. Removing a syslog IP address Use the following procedure to remove a syslog IP address. 1. Open the Switch the rule order and source IP address, and modify the service or destination port, protocol, policy to various switches. • The - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 77
48000 and Brocade DCX and DCX-4S enterprise-class platforms. Enabling or disabling a blade Use the following procedure to enable or disable a blade. 1. Open the Switch Administration window as described on page 41. 2. Click the Blade tab (Figure 23). FIGURE 23 Blade tab The Firmware Version columns - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 78
, use the Show IP Address button. 1. Open the Switch Administration window as described on page 41. 2. Click the Blade tab. 3. Click Show IP Address. 4. Scroll through the list to view all the information. 5. When you are finished, click Close. 46 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 79
window that asks if you want to save the changes to the switch. You must click Yes to save the changes. Changing the switch name Switches can be identified by IP address, domain ID, World Wide Name (WWN), or switch names. Names must begin with an alphabetic character, but otherwise can consist - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 80
Open the Switch Administration window as described on page 41. 2. Click the Switch tab. management on the switch, because traffic bypassing the power-on self test (POST). 1. Open the Switch Administration window execute the normal power-on booting sequence. 1. Open the Switch Administration window as - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 81
can configure fabric parameters. You can change the following system configuration parameters: • Switch fabric settings • Virtual channel settings • Arbitrated loop parameters • System services • Signed firmware Configuring fabric settings Perform the following steps to configure the fabric settings - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 82
default BB Credit is 16. The range is 1-27. R_A_TOV Resource allocation timeout value (in milliseconds). This variable works with the E_D_TOV to determine switch actions when presented with an error condition. The default range is 256-2112. Sequence Level Switching Select reboots, power cycles, - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 83
are reserved for switch internal functions. ATTENTION The default virtual channel settings are already optimized for switch performance. Changing the default values can improve switch performance, but can or absence of new or pre-existing devices. Web Tools Administrator's Guide 51 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 84
5. Click Apply. 6. Enable the switch as described in "Enabling and disabling a switch" on page 47. Configuring signed firmware When the firmware is downloaded to a device, the system can validate the firmware based on a configuration setting. By default, the signed firmware download is not validated - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 85
with switch software or refer to the Fabric OS Administrator's Guide for instructions on how to obtain a license key at the Brocade Web site (www.brocade.com or the 7500E and 7800 upgrade license, do not take effect until the switch is restarted. Web Tools Administrator's Guide 53 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 86
can enable slot based licenses only on a license key. 1. Open the Switch Administration window as described on page 41 switch Use the following procedure to remove a license from a switch in the Switch will no longer work. 1. Open the Switch Administration window as described on page 41. - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 87
are supported for universal time based license: Services and Initiate Failover buttons are unavailable. Launching the High Availability window Use the following procedure to launch the High Availability window. 1. Select a Brocade 48000, Brocade DCX, or Brocade DCX-4S from the Fabric Tree. The Switch - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 88
. When the hardware is configured as a dual switch, the Service tab displays information about both switches. • The CP tab displays information about slots. For Brocade 48000 and Brocade DCX-4S, CP blades are placed in slot 5 and slot 6, and for Brocade DCX, CP blades are placed in slot 6 and 7. In - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 89
switch is not a member of the current Admin Domain, the Synchronized Services and Initiate Failover buttons are unavailable. Synchronizing Services on the CP A nondisruptive CP failover is only possible when all the services Services. The Warning dialog synchronization of services, so that - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 90
Critical Critical-level messages indicate that the software has detected serious problems that will eventually cause a partial or complete failure of a subsystem if not corrected immediately; for example, a power supply failure or rise in temperature must receive immediate attention. Error - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 91
columns are displayed. Filtering Switch Events You can filter the fabric and switch events by time, severity, message ID, and service. You can apply either Open the Switch Events tab as described in "Displaying Switch Events" on page 58. 2. Click Filter. Web Tools Administrator's Guide 59 53- - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 92
in "Displaying Switch Events" on page 58. 2. Click Filter. The Event Filter dialog box displays. 3. Check Level. 4. Check the event levels you want to display. 5. Click OK. The filter is enabled and the window is refreshed to show the filtered information. 60 Web Tools Administrator's Guide 53 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 93
3. Check Service. The event service menu is enabled. 4. Select either Switch or Chassis from the menu to show only those messages from the logical switch or from displayed. Admin Domain considerations: The Name Server table is filtered based on Admin Domain membership of the fabric devices. The Name - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 94
in the Name Server window, and type an auto-refresh interval (in seconds). The minimum (and default) interval is 15 seconds. Printing the Name Server entries Use the following procedure to set up printing Tasks menu. The Name Server window displays. 62 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 95
that cycles through all ports for each switch (from left to right). NOTE You must have an RBAC role of admin to initiate switch beaconing. The LED light pattern is initiated on the actual switch or chassis. It is not mirrored in the Switch View. Web Tools Administrator's Guide 63 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 96
using the drop down list under Fabric Tree section in the Switch Explorer window. The selected switch displays in the Switch View. 2. Click Chassis Beacon. The LEDs on the logical switch light up on the blades associated with the logical switch. 64 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 97
Virtual Fabrics feature allows SAN design and management to be done at the granularity of a port. This enables partitioning of a physical switch into multiple logical switches, which may be organized into logical fabrics. The following platforms are Virtual Fabrics-capable: • Brocade DCX and DCX-4S - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 98
View. If you do not log in to a specific logical switch, you are presented with the default logical switch. Figure 32 is an example. FIGURE 32 Default logical switch 1. To select a different logical switch, use the Logical Switch selector to select the fabric ID, as shown in Figure 33. You must - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 99
dialog box, the default logical switch is displayed in the Switch View, as shown in Figure 32. • Allow XISL Use indicates whether or not the logical switch is allowed to connect to other logical switches using an extended inter-switch link (XISL). XISL). Base switches may use XISLs. Dynamically - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 100
base fabric is formed that includes logical switches in different chassis. A logical link is formed dynamically among logical switches that have the same FID to carry frames between the logical switches. Logical ports are created in the respective switches to support 's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 101
and downloading from USB storage 74 •Performing a firmware download 75 •Switch configurations for mixed fabrics 78 Creating a configuration backup By default, Config Upload is chosen under Function, and Network is chosen as the source of the configuration file. Web Tools Administrator's Guide 69 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 102
in the Host Name or IP field, the user ID and password required for access to the host in the User Name and Password fields, and choose the Protocol Type used for the upload. The default is FTP. If you to step 6. FIGURE 37 USB configuration upload 70 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 103
IDs that have been defined, the default of 128 for the physical switch, chassis level configuration, and all chassis and switches. NOTE If you are using a default, Config Upload is chose under Function, and Network is chosen as the source of the configuration file. Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 104
to Switch. 6. If you download from a network, type the host name or IP address in the Host Name or IP field, the user ID and password required for access to the host in the User Name and Password fields, and choose the Protocol Type used for the upload. The default - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 105
switch to which the default of 128 for the physical switch, chassis level configuration, and all chassis and switches. 10. Type the fabric ID of the logical switch switch as a physical fabric administrator and back up a configuration, all local switch not own the switch and you the switch and - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 106
the Admin Domain context" on page 25 for complete instructions. The EGM license is required only for 8 Gbps platforms, such as the Brocade DCX and DCX-4S enterprise-class platforms, the Encryption Switch, the 300, 5300, and 5100 switches. For non-8 Gbps platforms, all functionalities are available - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 107
this happens, contact your switch support supplier. NOTE You can perform a firmware download only when the current Admin Domain owns the switch. 1. Open the Switch Administration window as described on page 41. 2. Click the Firmware Download tab. Web Tools Administrator's Guide 75 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 108
can specify only a firmware path or directory name. No other fields on the tab are available. The USB button is available if the USB is present on the switch. 5. Type the host name or IP address, user name, " in the User field. 7. Click Apply. 76 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 109
directly to the blade, you have more options on the Firmware Download tab, as shown in Figure 42. Also, for the Brocade 7600 a collapsible area displays on the Firmware Download tab to show application firmware information. NOTE SAS is supported only on Brocade 7600 and FA4-16. In addition to - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 110
configurations for mixed fabrics FIGURE 42 Firmware Download tab for bladed switches Switch configurations for mixed fabrics You can use Web Tools to configure switches in a mixed fabric. You do this by setting the switch to interoperability mode, which is McDATA Open Fabric mode or McDATA Fabric - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 111
Fabric mode is calculated based on the offset selected. • switch if the Admin Domain you are logged into owns the switch. 3. Click the Configure tab, and then click the Interoperability subtab. FIGURE 43 Configure tab, Interoperability tab 4. Select the required mode: Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 112
from the Domain Offset (Hex) / Domain ID (Hex) drop down list. The available offset values are 0 (0x00), 32 (0x20), 64 (0x40), 96 (0x60), 128 (0x80), 160 (0xA0), and 192 (0xC0). McDATA Open Fabric Mode supports 239 (0xFF) also. 5. Click Apply. 80 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 113
can create Admin Domains based on the type of switches in your fabric using the WWN (not to be confused with the Admin Domain number) or put all the devices in a particular department in the same Admin Domain for ease of administering those devices. You can have up to 256 Admin Domains in - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 114
, switches, and switch ports switches running Fabric OS versions earlier than 5.2.0, as they can never be part of an Admin Domain unless they are upgraded switches that you explicitly add to AD0 and can be used to force device and switch contains all devices, switches, and switch ports in the - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 115
Brocade DCX and DCX-4S enterprise-class platforms, the Encryption Switch, the 300, 5300, and 5100 switches Switches switches Domain. • A switch to which the default SAN, you must set the default zone mode to No Access. You must be in AD0 to change the default zone mode. After the default the default zone - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 116
is denied and an error message displays. Change the Default Zone mode to No Access. Refer to "Setting the default zoning mode" on page 137 for more information. , such as the Brocade DCX and DCX-4S enterprise-class platforms, the Encryption Switch, the 300, 5300, and 5100 switches. For non-8 Gbps - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 117
display detailed information about that Admin Domain, as shown in Figure 46. The detailed view displays summary information as well as information about the online switch, port, and device members of the selected Admin Domain. Web Tools Administrator - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 118
only displays launched switches and their ports. It also displays all the devices in the fabric. Slot and port information of other switches are not if the table does not have any content. NOTE You must accept the Brocade Certificate at the beginning of the log in to Web Tools to enable the - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 119
information When you refresh, the system updates the display of fabric elements only (switches, ports, and devices). It does not update Admin Domain changes in the Admin The status for the fabric, including switches, ports, and devices is refreshed. Web Tools Administrator's Guide 87 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 120
you save the changes. That means that any other user looking at the Admin Domain information for the switch will not see the changes you made until you save them. 1. Click Actions > Save AD Configuration Domain session without saving the changes. 88 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 121
to an Admin Domain that was deactivated. The following procedures provide detailed instructions for creating an Admin Domain and for activating or deactivating an existing Create Admin Domain wizard opens. FIGURE 48 Create Admin Domain wizard Web Tools Administrator's Guide 89 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 122
it. This is the default setting. Clear the Active • Select a switch, port, or switch or slot and click Add Ports to add all of the ports in the selected switch or slot. • Select a switch Manual to add offline devices. NOTE To add ports or other switches in the fabric, you must do it from the Manual - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 123
ports and all logical ports if the 7500E upgrade license is not installed. 8. Click Next. switches to the fabric Use the following procedure to add ports or switches to the fabric. 1. From the Create Admin Domain wizard, click Manual. The Add Member window displays. Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 124
. When you deactivate an Admin Domain, no one can use this Admin Domain to log in to a switch. Modifying Admin Domain members Use the following procedure to modify members from an Admin Domain. 1. Open the wizard opens on the Membership step. 92 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 125
Add Devices to add all of the devices for the selected element. Optional: Click Manual to add offline switches and devices. 5. Remove members from the Admin Domain by selecting them in the Domain configuration as the effective configuration. Web Tools Administrator's Guide 93 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 126
the Admin Domain configuration, all user-defined Admin Domains are deleted and all fabric resources (switches, ports, and devices) are returned to AD0. You cannot clear the Admin Domain configuration configuration. 4. Click No to cancel the action. 94 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 127
can only view the port information. Opening the Port Administration window To open the Port Administration window, do the following: • Click Port Admin in the Switch View to open the Port Administration window. The window opens in Basic Mode (Figure 53 on page 96). Refer to - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 128
6 Port management overview FIGURE 53 Port Administration window, FC Ports, Basic Mode The Port Administration window displays information about the ports on the switch. Click Show Advanced Mode in the upper-right corner of the window to see more port management options (Figure 54). 96 Web Tools - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 129
Domain: • Direct members are ports that were directly added to the Admin Domain as members. • Indirect members are: - non-owned ports on a member switch - non-owned ports to which member devices are attached • All active ports, as well as any inactive EX_Ports are shown. Web Tools Administrator - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 130
switch (physical FC ports and logical FCIP ports) • GigE Ports to display all of the GbE ports If the switch Operational Status • GigePort • Source IP • Gateway • VLAN ID • Switches-Switch ID, with switch name in parentheses; for example, 3(MapsSW_202) - Blades-Slot number of the blade, with blade - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 131
- If you select a slot or switch, the system displays a table of all the ports for the slot or switch (Figure 55 on page 101). - FCIP tunnels for that GbE port. - IP Interfaces-GbE ports only - IP Routes-GbE ports only • When viewing detailed Credit Web Tools Administrator's Guide 99 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 132
and indirect member ports on non-owned switches are accessible in read-only mode and the current Admin Domain and for all ports on switches that are owned by the current Admin Domain, if functionality is enabled. Ports on a non-owned switch that are not E_Ports and are neither direct nor - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 133
allowed port types, port speed, and long distance mode for physical ports. You must use Web Tools with the EGM license enabled on the switch to configure long distance; otherwise, access to this feature is denied and the following error message displays. FIGURE 56 Missing EGM license Web Tools - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 134
8 Gbps platforms, such as the Brocade DCX and DCX-4S enterprise-class platforms, the Encryption Switch, the 300, 5300, and 5100 switches. For non-8 Gbps platforms, all if the EGM license is not enabled on the switch. 5. Click Edit Configuration. 102 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 135
can be used to connect to another switch. U_Port For a physical FC port: switch comes up, depending on what type of device or switch switch must be capable of supporting FCR or FCIP features. The EX_Port option is disabled in the wizard if the switch be enabled on the switch; otherwise, access to - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 136
Brocade DCX and DCX-4S enterprise-class platforms, the Encryption Switch, the 300, 5300, and 5100 switches Brocade 300, 5100, 5300, Brocade Encryption Switch, Brocade switches and Brocade 48000 and Brocade DCX and DCX-4S enterprise-class platforms with FR4-18i blades 32 Switch View to open - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 137
. 1. Click a port in the Switch View to open the Port Administration window. on the left, click the switch or slot that contains the port and FC4-16IP port blades, all ports are disabled by default. You can disable the path to communicate with the principal switch), the fabric reconfigures. • If you - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 138
Disable. NOTE Persistent Enable or Disable is not supported in FMS mode. If the button is gray (unavailable , refer to the Fabric OS Administrator's Guide. With Web Tools, you can only Access gateway mode is enabled. 1. Click a port in the Switch View to open the Port Administration window. 2. Click the FC - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 139
5000 Brocade 4100 Brocade 4900 Brocade 4024 Brocade 4020 Brocade 4018 Brocade 4016 Brocade 300 0-15 Not supported None 1-8, 17-20 1-8, 17-20 0-47 0-23 0-15 0-31 1-8, 17-20 0-7, 15, 16 0-11 0-7, 10-13 0-7 0-7 9-12, 21, 22 0, 13-16, 23 9-16, 21-23 0 48-63 64-79 24-31 32-39 16-23 24-31 32-47 48-63 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 140
the Brocade Ports on Demand licensed product. For instructions, refer to "Activating a license on a switch" supported on the Brocade 4018, 4020, 4024, 5460, and 5470 switches only. If you click the Enable DPOD button on an unsupported switch, an error message displays. 1. Click a port in the Switch - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 141
PODs feature is supported on the Brocade 4018, 4020, and 4024 switches only. You must disable the port or switch before reserving or releasing a license. 1. Click a port in the Switch View to open Release License in the Port Administration window. Web Tools Administrator's Guide 109 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 142
is on a blade, you must also provide the slot number. Port swap is not supported above 16th port in 48 port card in FMS mode. 8. Click Swap. Determining if a port index was swapped with another switch port Use port index the port was swapped. 110 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 143
credits on an F_Port From 6.3.0 you can configure the BB credits value on an F_Port. Follow the steps given below. 1. Click a port in the Switch View to open the Port Administration window. 2. Click the FC Ports tab. 3. Click Show Advanced Mode. i FIGURE 60 F-Port BB Credit button 4. Click F-Port - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 144
is 8. NOTE You cannot modify the default BB credit value for VE and ICL ports. 6. Click Ok. The value is displayed in the table of the Port Administration window. If no value is configured the F-Port BB Credit column displays the default value. 112 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 145
to the Fabric OS Administrator's Guide. You must use Web Tools with the EGM license to create ISL trunk groups and to manage F_Port trunks. NOTE The EGM license is required only for 8 Gbps platforms, such as the Brocade DCX enterprise-class platform, the Encryption Switch, the 300, 5300, and 5100 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 146
default on all ports. Use the following procedure to disable trunking on a port or to re-enable trunking if it has been disabled. Trunking is not supported on logical ports or GbE ports. 1. Click a port in the Switch current Admin Domain owns the switch. You can log into a switch that is not in your - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 147
group information 7 Viewing trunk group information Use the Trunking tab on the Switch Administration window to view trunk group information (Figure 63). FIGURE 63 Trunking to F_Port trunking). • Trunk index (applies only to F_Port trunking). Web Tools Administrator's Guide 115 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 148
the same. NOTE If F_Port trunking is configured, a firmware downgrade is not allowed. Creating and maintaining F_Port trunk groups blade port ranges 0-7, 8-15, which are applicable to front end ports. On the Brocade Encryption Switch, the trunk groups are in the following port ranges 0-7, 8-15, 16 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 149
from the trunk group, select the port from Trunk Groups table and then click Remove Members. 9. Click OK when you are finished. Web Tools Administrator's Guide 117 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 150
7 F_Port trunk groups 118 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 151
only for 8 Gbps platforms, such as the Brocade DCX and DCX-4S enterprise-class platforms, the Encryption Switch, the 300, 5300, and 5100 switches. For non-8 Gbps platforms, all functionalities are with an admin, switchadmin, or fabricadmin role. Web Tools Administrator's Guide 119 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 152
window displays predefined reports and filter-based performance monitoring. You can use this performance monitoring, refer to the Fabric OS Administrator's Guide. Each graph is displayed individually in a window charts for Brocade 7800 Extension Switch and FX8-24 DCX Extension Blade. This option - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 153
, and 7800 Extension switches include physical FC ports, logical FC ports, and GbE ports. The Brocade FC4-16IP blade includes physical FC ports and GbE ports. Not all of the performance monitoring graphs support the logical FC ports and GbE ports. Web Tools Administrator's Guide 121 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 154
Performance P P SCSI Commands P SCSI vs. IP Traffic P 1. Blade Aggregate Throughput graph is supported only on the Brocade 48000 and Brocade DCX and DCX-4S enterprise-class platforms. The labeling of axes in the graphs depends on the switch type: • For the Brocade 48000 and DCX and DCX-4S - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 155
. This example displays the graphs available in the Performance Monitoring window for a Brocade 48000 director with the Advanced Performance Monitoring license installed. Note that the slot number is with a name and an optional brief description. Web Tools Administrator's Guide 123 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 156
. Use the following procedure to open the Web Tools Performance Monitoring window. 1. Select a switch from the Fabric Tree and log in when prompted. 2. In the Monitor area under Tasks Click Performance Graphs > Basic Monitoring > Graph Type. 124 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 157
slot,port field, or manually type the slot and port information in the field, in the format slot,port. For Brocade 200E, 300, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 5100, 5300, 7600 switches, the 7500, 7500E and 7800 Extension switches, the 8000, and the Encryption Switch, enter only a port - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 158
monitor graphs" on page 124 for instructions on creating a graph. 2. For Brocade 48000 and Brocade DCX and DCX-4S enterprise-class platforms Switch Throughput Utilization graph. FIGURE 69 Select Ports for customizing the Switch Throughput Utilization graph 126 Web Tools Administrator's Guide 53 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 159
expand the slot or port list. For the Brocade 48000, Brocade DCX and Brocade DCX 4S enterprise-class platforms, click the plus The advanced monitoring graphs are not supported for GbE ports. NOTE You between a SID-DID pair on the switch being managed. 1. Open the Performance Guide 127 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 160
in the fabric and lets you select the source and destination. Slot and port information of other switches is not displayed in the tree. 3. Click a port from the Slot/Port or Sid/Did the monitor is saved, and will persist if the switch is restarted. 128 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 161
graphs 8 Creating a SCSI vs. IP Traffic Graph The SCSI vs. IP Traffic graph displays the SCSI versus IP traffic for selected ports. For Brocade 48000 and Brocade DCX and DCX-4S enterprise-class platforms on a LUN per port Setup dialog box. Web Tools Administrator's Guide 129 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 162
Brocade 4100 or 5000 Switch, you can enter up to eight LUN masks. For the Brocade 48000 director, you can enter up to four LUN masks. For all other switches TCP graphs for a switch at a time. A total of 16 TCP connection graphs can only be launched for a switch. For TCP connection Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 163
you want to generate the graphs. For Brocade 7800 extension switch, you can have maximum four circuit connections in a tunnel and for FX8-24 DCX extension blade, you can have maximum 10 circuit connections Click Reset to reset all the graphs. Web Tools Administrator's Guide 131 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 164
click Save Canvas. A message displays, confirming that the configuration was successfully saved to the switch. Adding graphs to an existing canvas The following procedure assumes that a canvas is already to add it to the canvas, and click Save. 132 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 165
. 7. Click Save to save the changes and close the Performance Monitor Canvas dialog box. 8. Click Close to close the Canvas Configuration List. Web Tools Administrator's Guide 133 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 166
8 Modifying graphs 134 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 167
8 Gbps platforms, such as the Brocade DCX and DCX-4S enterprise-class platforms, the Encryption Switch, the 300, 5300, and 5100 switches. For non-8 Gbps platforms, all DCFM Enterprise Edition Live Fabric library scope yes yes QoS support yes yes Remove offline devices no yes Device to zone, - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 168
SAN) into logical groups of devices that can access each other. For example, you can partition a SAN merge fabrics. Extension switches like the 7500 provide A QoS zone is a special zone that assigns a Quality of Service (QoS) level for traffic flow between a given host or target Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 169
any other device in the fabric. Web Tools supports default zoning on switches running firmware v5.1.0 or later. Default zoning on legacy switches (switches running firmware versions prior to v 5.1.0) are not supported. Legacy switches can use default zoning; however, they cannot manipulate the - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 170
the switch using switch, or select a virtual switch using the drop down list under Fabric Tree section in the Switch Add Other button to add ports of other switches in the fabric. FIGURE 73 Zone Administration window to the zoning database on the switch, refer to "Saving local zoning changes" on - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 171
switch and the devices of all the switches in the fabric. Slot and port information of other switches blade in it; they are shown under a separate folder icon called Virtual Initiators. If the chassis has the Brocade 7500E Extended Switch of fabric elements only (switches, ports, and devices). - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 172
you save the changes. In that case any other user looking at the zone information for the switch will not see the changes you have made until you save them. Saving the changes propagates any at any time during the Zone Administration session. 140 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 173
a list of the FC Virtual Initiators on switches that support iSCSI. In the Fabric View, you can select ports for port-based zoning or devices for WWN-based zoning. • Devices Only-Displays a list of Alias. The Create New Alias dialog box displays. Web Tools Administrator's Guide 141 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 174
"Enabling zone configurations" on page 149. Renaming zone aliases The new alias name cannot exceed 64 characters and can contain alphabetic, numeric, and underscore characters. Use the following procedure to change save and enable your changes. 142 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 175
. 6. Click Zoning Action > Save Config to save the configuration changes. To enable the configuration, refer to "Enabling zone configurations" on page 149. Web Tools Administrator's Guide 143 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 176
Zoning management Creating and populating zones A zone is a region within the fabric where specified switches and devices can communicate. A device can communicate only with other devices connected to the Zone Members list that you want to delete. 144 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 177
only for 8 Gbps platforms, such as the Brocade DCX and DCX-4S enterprise-class platforms, the Encryption Switch, the 300, 5300, and 5100 switches. For non-8 Gbps platforms, all functionalities are do not need to enable the configuration. Web Tools Administrator's Guide 145 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 178
TI zones can be configured. LSAN devices can be added only in TI zones created in the backbone switch. Use the following procedure to create and populate a TI zone. 1. Open the Zone Administration window as the traffic isolation zone configuration. 146 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 179
page 137. 2. Select a format to display zoning members in the Member Selection List as described in "Select a zoning view" on page 141. Web Tools Administrator's Guide 147 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 180
Enabling zone configurations" on page 149. Renaming zone configurations The new name cannot exceed 64 characters and can contain alphabetic, numeric, and underscore characters. Use the following procedure from the Name list and click Rename. 148 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 181
to save the configuration changes. Enabling zone configurations Several zone configurations can reside on a switch at the same time, and you can quickly alternate between them. For example, you summary displays the maximum zoning database size. Web Tools Administrator's Guide 149 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 182
Zoning is disabled on the fabric, and according to the default zone set, devices within the fabric can or cannot communicate with enabled zone configuration. If there is no active zone configuration enabled on the switch, a message is displayed to that effect. NOTE The enabled configuration is - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 183
the following: • Select a switch from the Fabric Tree. The selected switch displays in the Switch View. The current zone configuration in the lower-right corner. It is also updated if you manually refresh the Zone Administration window contents by clicking the refresh icon Guide 151 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 184
, indicating that there is no active zoning configuration on the switch. 3. Optional: Click Print located in the Print Effective Zone that will include the new WWNs. All of the elements are selected by default. 4. Click items in the list to select or unselect, and click Add Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 185
is an alias or zone, then the search domain includes elements like switch names and domain numbers, port names and "domain, port" addresses, can be added or its parent or children can be found. By default, the Member Selection List is searched from beginning to end one time. Guide 153 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 186
Zone using the core switch versus an edge switch. • Zone using a director over a switch. A director has more resources to handle zoning changes and implementations. • Zone on the switch you connect to when bringing up Web Tools (the proxy switch). 154 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 187
Brocade switch. The dump can be used by developers and troubleshooters at Brocade to help understand what might be contributing to a specific switch ." A trace dump is generated when: • It is triggered manually (use the traceDump command). • A critical-level LOG message Guide 155 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 188
, if a problem occurs you can provide your customer support representative with the most detailed information possible. To ensure the best service, you should set up for automatic transfer as part of standard switch configuration, before a problem occurs. 156 Web Tools Administrator's Guide 53 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 189
(Trace dumps overwrite each other by default; sending them to a server preserves Switch Administration window. 2. Click the Show Advanced Mode tab, if it is not selected. 3. Click the Trace tab. 4. Type the FTP host IP a trace dump is disabled, you must manually upload the trace dump or else the - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 190
switch information Displaying switch information You can right-click in the table content of Fan, Temperature, and Power Status windows to find Export, Copy, and Search options. These options are not available if the table does not have any content. You must accept the Brocade about the switch fan, - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 191
Sensor States window Viewing the power supply status The icon on the Power button indicates the overall status of the power supply status. For more information regarding switch power modules, refer to the appropriate hardware documentation. Web Tools Administrator's Guide 159 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 192
from the Fabric Tree. The selected switch displays in the Switch View. The icon on the Power button indicates the overall status of the power supply. 2. Click Power on the Switch View. The detailed power supply states are displayed. FIGURE 80 Power Status window Checking the physical health of - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 193
details of only those ports which are members of the current Admin Domain context and the E_Ports of the switch. 4. Optional: Rest the cursor on the Action bar (Figure 82) and click an action to perform report • View the XML schema for the report Web Tools Administrator's Guide 161 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 194
viewing. (The blink rate of the LEDs in the Switch View does not necessarily match the blink rate of the LEDs on the physical switch.) NOTE All 8G platform Brocade switches and port blades do not have port speed LEDs, but only port status LEDs. 162 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 195
4100 switch. For the Brocade 4100, the top row of LEDs corresponds to the upper port, and the bottom row of LEDs corresponds to the lower port. Brocade 4100 FIGURE 83 Port and LED status color-coded information in the Port icon in Switch View Web Tools Administrator's Guide 163 53-1001343 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 196
10 Port LED interpretation Brocade 48000 Director LEDs For the Brocade 48000 director, the representation of the port LEDs on the FC4-32 port blade is not the same as the LEDs on the physical blade. Figure 84 on page 164 compares the LEDs on the physical port card and the Web Tools display. - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 197
only on the base switch. EX_port configurations are supported only on the base switch. Also, because FC ports on 7500 extension switches cannot be added to a base switch, EX_port configuration for FC ports on 7500 extension switches is blocked. Web Tools Administrator's Guide 165 53-1001343 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 198
supported only on the following switch models: • Brocade 5100 and 5300 switches, and the 7500, 7500E and 7800 Extension Switches. • Brocade 48000 director, when configured with an FR4-18i blade. • Brocade DCX and DCX-4S enterprise-class platforms, when configured with FR4-18i, FR8-16, FR8-32, FR8-48 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 199
instructions service switches, 7500, 7500E, and 7800 Extension Switches. • Brocade 48000 director, when configured with an FR4-18i blade. • Brocade DCX and DCX-4S enterprise-class platforms, when configured with FR4-18i, FR8-16, FR8-32, FR8-48, or FX8-24 blades. Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 200
is disabled, the table and tree nodes in this tab are empty and the tree displays only the backbone switch.) For more detailed information about a specific LSAN fabric, click a fabric name in the table and then click table on the LSAN Fabric tab. 168 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 201
the following url: http://ip-address-of-lsan-fabric-switch For Brocade switches, this launches Web Tools. For non-Brocade fabrics, this launches the element manager for that switch. FIGURE 86 FC Routing task in the task bar: • Configure EX_Ports Web Tools Administrator's Guide 169 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 202
, but you can select only one port at a time in the tree. FIGURE 87 FC Routing module with EX_Ports tab selected 170 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 203
Brocade 7800 extension switch and FX8-24 blade, New button is enabled only if Integrated Routing license is present. This opens the port configuration wizard, which guides you through the port configuration process. 4. Follow the instructions or tunnel path is chosen based on the minimum cost per - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 204
11 Viewing LSAN zones 1. Open the Switch View window. 2. Click FCR in Manage section of the Tasks menu. 3. Click the Ex_Ports tab. 4. Click the Router Port Cost physical and proxy LSAN devices. Note that this count is for all of the LSAN fabrics. 172 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 205
fabric ID, you must disable the switch; however, all the Ex_Ports must be Make sure that all switches in the backbone fabric have the same fabric ID. 1. Open the Switch View window. 2. Click 4. Remove all the EX_ports configuration and disable the switch. 5. Click the General tab. 6. Click Set - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 206
fabric ID is a number from 1 through 128. Web Tools warns you if you select a fabric ID that is already in use. 8. Click OK. 9. Enable the switch and manually enable FC-FC Routing Service. 174 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 207
4016, 4018, 4020, 4024, 4424, 200E, 300, and the Brocade Encryption switches. For detailed descriptions of the Access Gateway, refer to the Brocade Access Gateway Administrator's Guide. NOTE When Access Gateway mode is enabled on switches managed through Web Tools, only a limited subset of menus and - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 208
Gateway mode The Access Gateway mode Switch Explorer is divided into the following areas: • Menu bar • Tasks • Switch View buttons • Switch Events and Access Gateway information • Indicator bar • Professional Management Tool offering • Switch View 176 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 209
Brocade Encryption switch 12 Access Gateway mode on Brocade Encryption switch The Access Gateway feature on Brocade Encryption switches enables interoperability with the Cisco fabrics. The Access Gateway mode of the switch • Edit/View • Delete Web Tools Administrator's Guide 177 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 210
12 Access Gateway mode on Brocade Encryption switch FIGURE 91 Port Group Configuration - view only • Configure F-N Port Mappings Add and Remove buttons are Figure 92. FIGURE 92 F-N Port Mapping Configuration - view only • N Port Configuration 178 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 211
Gateway mode 12 By default all the ports are Switch Status section. You can enable Access Gateway mode only after the switch is disabled. 4. Click Enable in the Access Gateway Mode section. 5. Click Apply. 6. Click Yes to restart the switch in Access Gateway mode. Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 212
switch. 2. Click Switch Admin in the Manage section under Tasks. The Switch Administration window opens. 3. Click Disable in the Switch switch is disabled. 4. Click Disable in the Access Gateway Mode section. 5. Click Apply. 6. Click Yes to restart the device in native switch the selected switch. The - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 213
initial defaults for port types, groups, and the F_Port-to-N_Port mappings. When the policy is Automatic, the port type assignments and mappings are configured automatically based on device and switch the Port Configuration Policy drop-down list. Web Tools Administrator's Guide 181 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 214
field. 7. Select the Login Balancing check box to enable login balance for the port group. 8. Select the Fabric Name Monitoring check box to manually configure the managed fabric name monitoring. 9. Under the Select Members(N-Port)* section, select the required ports you want to group. 10. Click - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 215
procedure to edit port groups. 1. Click a port in the Switch View to open the Port Administration window. 2. Click Configure N_Port Port Auto Rebalancing and N-Port Auto Rebalancing check boxes and Manual Balancing button gets enabled. 6. Click Failover Enable. A confirmation Guide 183 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 216
port groups. NOTE You cannot delete the default port group 0 (pg0). 1. Click a port in the Switch View to open the Port Administration window. and secondary mapping Use the following procedure to manually change port mappings. 1. Click a port in the Switch View to open the Port Administration window. - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 217
port group. 6. After you have made the appropriate changes, click Save. Access Gateway policy modification Although you can control a number of policies on switches in Access Gateway mode, Web Tools only provides the ability to enable and disable the policies. For more information on these policies - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 218
policy is a global configuration policy for a switch in Access Gateway mode. By default, this policy is disabled. If you created an N_Port grouping and switching over to the automatic mode, those port box through the Port Administration window. 186 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 219
3. Click Yes in the confirmation window. 4. In the Switch Explorer window select Switch Admin. The Switch Administration window displays. FIGURE 101 Access Gateway Auto Rebalancing 5. F Port Auto Rebalancing check box to enable F_Port rebalancing. Web Tools Administrator's Guide 187 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 220
12 Access Gateway policy modification • Click Manual Balancing and a confirmation dialog box displays. Click Yes to change F Port - N Port Mapping or click No to cancel the changes. 7. Click Apply to apply the changes. 188 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 221
information 195 •E-mail notification 196 Fabric Watch overview Fabric Watch is an optional Brocade licensed feature that monitors the performance and status of switches. Fabric Watch can automatically alert you when problems arise, before they become costly failures. NOTE Fabric Watch is view-only - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 222
perform Fabric Watch operations using Web Tools and Web Tools with the EGM license. NOTE Unless the switch is a member of the current Admin Domain context, Fabric Watch is view-only. FIGURE 102 to identify unacceptable values (threshold traits). 190 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 223
the following procedure to open the Fabric Watch window. 1. Select a switch from the Fabric Tree and log in if necessary. 2. Select Tasks You can configure the following traits for a threshold: • Time Base-The time base (second, minute, hour, day) for the area • Low 's Guide 191 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 224
column. 6. In the Activate Level area: • Use the system default settings and proceed to step 11. or • Click Custom Defined to specify new settings and proceed to the next step. 7. If necessary, select a time to record the event in the Time Base field. 8. Type the lowest boundary of the normal zone - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 225
Default and Custom Defined. You cannot modify the information in the System Default table. 6. In the Activate Level area: • Click System Default o use the system default switch; not all alarm options are available for all switches. For more information, refer to the Fabric Watch Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 226
the other classes. Because FRUs are not monitored through a threshold-based system, they have a simpler interface for configuration. For FRUs to apply the changes to the switch. A confirmation dialog box displays, asking if you want to apply the changes to the switch. 8. Click OK in the confirmation - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 227
a previously configured element from Fabric Watch Explorer (for instructions, refer to "Enabling or disabling threshold alarms for individual refers to either a fan or a fan FRU, depending on the switch model. Refer to "Viewing detailed fan hardware status" on page 158 Guide 195 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 228
For troubleshooting responses to alarms, refer to the Fabric Watch Administrator's Guide. Switch Administration window as described on page 41. 2. Click the Switch tab. 3. In the DNS Configuration area, in the DNS Server 1 field, type the primary domain Name Server IP address. You can enter the IP - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 229
is working correctly. You can send a test e-mail only after you have applied your settings. FIGURE 104 Fabric Watch Email Configuration tab Web Tools Administrator's Guide 197 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 230
13 E-mail notification 198 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 231
Brocade DCX and DCX-4S enterprise-class platforms, the Encryption Switch, the 300, 5300, and 5100 switches , refer to the Fabric OS Administrator's Guide. The Extended Fabric tab displays the following supported for the LS and LD extended ISL modes only and is persistent across reboots, switch - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 232
or LS mode (Table 16 on page 201), the 16 describes the long-distance settings and identifies which settings require a Brocade Extended Fabrics license. FIGURE 105 Extended Fabric tab For Brocade switches without upgrade license. The Brocade Encryption Switch and the FS8-18 Encryption blade support - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 233
Advanced Mode. 3. Click the Extended Fabric tab. 4. This step is switch-specific: For Brocade DCX and Brocade 48000 enterprise-class platforms, click the slot subtab that corresponds to the correct slot for the logical switch. For Brocade 200E, 300, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 234
Long distance link with Credit Recovery". Click Yes to apply the changes, else click No to close the confirmation message window. 202 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 235
and each port supports 64 iSCSI sessions. The TCP/IP stack at the port provides support for multiple TCP connections over a single GbE port. In Web Tools, ports are addressed using slot number and port number notation (for example, 2,16): • For Fibre Channel ports on the FC4-16IP blade, the range of - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 236
. Supported platforms for iSCSI The iSCSI target gateway service is supported on the Brocade 48000 director with CP blades running Fabric OS v5.2.0 and later releases, and configured with an FC4-16IP blade. Common red color. FIGURE 106 Search screen 204 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 237
An intermediate device in the network that allows the iSCSI initiators in an IP SAN to access and utilize storage in a Fibre Channel SAN. the FC4-16IP AP blade in a Brocade 48000 director functions as an iSCSI target gateway. A special GbE port used for iSCSI only. A Fibre Channel virtual initiator - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 238
gateway services. The iSCSI Setup wizard guides you through the steps to set up iSCSI connectivity between IP networks and your Fibre Channel SAN. Click . This option is available on all Brocade 48000 switches with option 5 configured and with an FC4-16IP blade. NOTE Because the entire fabric is - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 239
Target Gateway Services 15 FIGURE 107 iSCSI Target Gateway Admin with the Targets tab selected 1. Select a switch from the Fabric Tree and log in, if necessary. The selected switch displays in Switch View. Make sure that your Admin Domain Context is either AD0 or AD255. Generally, the default user - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 240
that the blade is inserted in the director and powered on. 2. Open iSCSI Target Gateway Admin as described on page 206. 3. Click Enable iSCSI. 4. Click Apply. Encryption Services for the iSCSI Gateway Data-At-Rest encryption services for the iSCSI hosts is supported for the Encryption Switch and the - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 241
statistics. It also allows you to view and configure the IP interface and routes that are located on the IP Interface tab. You can edit or delete the IP address, but you cannot add any additional IP addresses to this interface. When you select the switch in the left pane, the right pane lists the - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 242
15 Setting up iSCSI Target Gateway Services Configuring the IP route is optional because when an IP address is set up, a route IP Interface dialog box 7. Enter the subnet mask. 8. Enter the MTU size or accept the default MTU size, and click OK. NOTE To change the IP address, delete the current IP - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 243
Services 15 Configuring the IP route (optional) Use the following procedure to configure the IP route. NOTE You can create maximum of 32 static IP 3. From the left pane, select the GbE port that to use. 4. Select the IP Routes tab. 5. Click Edit. A warning dialog box displays. 6. Click OK. 7. - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 244
15 Setting up iSCSI Target Gateway Services Creating iSCSI virtual targets SCSI virtual target creation is done from the first pane in the iSCSI Target LUN(s). This adds the selected LUNs to your virtual target. 8. Click Next and click Finish. 212 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 245
up iSCSI Target Gateway Services 15 Using Easy Create tab. 3. Click Easy Create. FIGURE 112 Easy VT Creation Dialog 4. Follow the instructions in the wizard to create a virtual target in iSCSI. The wizard is self-explanatory wizard opens. Web Tools Administrator's Guide 213 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 246
Domain management 5. Follow the instructions in the wizard to edit an not match. Viewing iSCSI Initiators When you set up the iSCSI target gateway on a switch, all initiators may not be online yet, but the initiators automatically pick up and 214 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 247
the right displays current members of the DD being viewed. Discovery domains can be created with virtual targets, iSCSI initiators, or both. Web Tools Administrator's Guide 215 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 248
You can enter the full or partial name of an iSCSI member in the IQN Name text box and click the Filter button. Based on the filter criteria, The Create DD wizard opens. FIGURE 115 Create DD wizard 4. Follow the instructions in the wizard to create an iSCSI discovery domain. The wizard is self- - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 249
iSCSI Target Gateway Admin as described on page 206. 2. Select the Discovery Domains tab. 3. Click Create DDSet. The Create DDSet wizard opens. Web Tools Administrator's Guide 217 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 250
CHAP Configuration FIGURE 116 Create DDSet wizard 4. Follow the instructions in the wizard to create an iSCSI discovery domain set . Each CHAP secret has: • User name maximum length of 64 characters • CHAP secret of maximum length of 32 characters 218 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 251
edit the CHAP secret, but not the CHAP user name. 4. Fill in the fields in the dialog box to edit a CHAP secret. Web Tools Administrator's Guide 219 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 252
redirection Connection redirection allows iSCSI sessions to be evenly distributed across ports on the same blade. Before the maximum number of connections is reached for any given port, logins are Select the Connection Redirection tab (Figure 118). 220 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 253
be able to add the zone that you create here to some or all of these configurations by selecting them from a list. Web Tools Administrator's Guide 221 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 254
target gateway service. The following default zoning conditions apply: • If default zoning is other without one. • If default zoning is set to All Access Because your default zoning is All Access with However, to avoid SAN congestion in the future instructions, refer to "Creating zone - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 255
then the configuration is re-enabled. This affects the entire SAN; the zoning database must update itself, and then replicate effective configuration is modified and re-enabled. Managing and Troubleshooting Accessibility The Web Tools iSCSI accessibility feature helps you 's Guide 223 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 256
15 Managing and Troubleshooting Accessibility 224 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 257
Fabric OS 6.3.0, the supported routing policies are as follows: • Port-based routing Port-based routing assigns a "static route," in which the path chosen for traffic never changes. • Exchanged-based routing Exchange-based routing policy is the default. Exchange-based routing policy always employs - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 258
on page 41. 2. Click the Routing tab. 3. This step is switch-type specific: For the Brocade 48000 and Brocade DCX and DCX-4S enterprise-class platforms, click a slot number under the FSPF Route category in the navigation tree. For Brocade 200E, 300, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 259
Specifying frame order delivery 16 When the port-based policy is in force, you can enable DLS to optimize routing. When DLS is enabled, it shares traffic among multiple equivalent paths between switches. DLS recomputes load sharing either when a switch boots up or each time an E_Port or FX_Port - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 260
16 default, "static" cost for any port. 1. Open the Switch Administration window as described on page 41. 2. Click the Routing tab. 3. This step is switch-specific: For the Brocade 48000 and Brocade the default value for that port. 6. Click Apply. 228 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 261
service management 250 •Active Directory service default accounts-root, factory, admin, and user-Fabric OS supports up to 256 user-defined accounts in each logical switch is logged in to by default. • Role-Determines functional that the user is logged in to by default. The home Admin Domain must be a - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 262
information about Role-Based Access Control (RBAC). The User tab of the Switch Administration window ( switch in the fabric. If no Home Domain is specified for a user, the system provides a default home domain. The default home domain for predefined account is AD0. User-defined accounts, the default - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 263
1. Open the Switch Administration window as described on page 41. 2. Click the User tab. A list of the default and user-defined switches that support Virtual Fabrics, refer to Figure 122. For switches that support Administrative Domains (AD), refer to Figure 123. Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 264
17 User-defined accounts FIGURE 122 Add User Account dialog box (VF) FIGURE 123 Add User Account dialog box (AD) 232 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 265
switch. 5. Select a role from the drop-down menu. For VF-enabled switches, the selection is done per logical fabric ID. (Refer to "Role-Based Access Control" on page 16 Home AD menu if Admin Domains are enabled. The default home logical fabric ID is 128. If AD0 is deselected Guide 233 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 266
Open the Switch Administration window You cannot delete the default accounts. An account Switch Administration window as described on page 41. 2. Click the User tab. 3. Select the account to modify. You cannot modify the default description of the default accounts. You cannot in to the switch. The All - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 267
Domains are selected, the next available Admin Domain becomes the user's default home Admin Domain. 10. Click OK and click Apply to apply the user to provide a new password. NOTE You have to own the switch in order to modify password rules. A password becomes locked if a user Guide 235 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 268
. Setting the rules for passwords Use the following procedure to set rules for passwords. 1. Open the Switch Administration window as described on page 41. 2. Click the User tab. 3. Click Set Password Rule. 7. Click Apply to save your changes. 236 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 269
to save your changes. Unlocking a password Use the following procedure to unlock a password. 1. Open the Switch Administration window as described on page 41. 2. Click the User tab. 3. Select the account. 4. . 5. Click Apply to save your changes. Web Tools Administrator's Guide 237 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 270
17 User-defined accounts Displaying roles and assigned logical fabrics You can display user role assignments for logical fabrics. 1. Open the Switch Administration window as described on page 41. 2. Click the User tab. 3. Select an account. 4. Select Show Role and VF. The Role Mapping for that user - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 271
control list policy configuration Support for the Access Control List (ACL) policies is currently defined in the Switch Connection Control (SCC) and Device Connection Control (DCC) policies. SCC and DCC policy configuration in base Fabric OS is performed on a switch-local basis. Fabric Configuration - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 272
or FCS policy You can create the FCS policy only once. 1. Open the Switch Administration window as described on page 41. 2. Click the Security Policies tab. switch and its ports are listed in the tree. All the devices in the fabric are also listed in the tree. 240 Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 273
for instructions. Editing an SCC, DCC, or FCS policy Use the following procedure to edit an SCC, DCC, or FCS policy. 1. Open the Switch Administration a switch or highlight multiple switches to add to the policy by clicking Add or Add All. 9. Select a switch or highlight multiple switches to - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 274
switches. The Delete All button is enabled only when there is at least one policy activated. 1. Open the Switch the Switch primary switch. 1. Open the Switch Select the switches to be switch position You can move the position of a primary switch in the FCS policy list. 1. Open the Switch - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 275
Apply. After you move all the member switches, click Apply and Close. Fabric-Wide ACL policies. The policy ensures that the switches in the fabric enforce the same policies. is not set, then the policies are managed on a per switch basis. FIGURE 128 FWCP Configuration Use the following procedure to - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 276
switch is not a primary switch, an error message dialog box is displayed as shown below. Click No to discard the changes and click Refresh in the FWCP Configuration window to manually configure authentication policies for E_Ports. 1. Open the Switch Administration window as described on page 41. 2. - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 277
switch authentication policy mode: : On Strict authentication is enforced on all E_Ports. Active The switches can be connected to a switch with any type of policy. Passive The switch switch does not support authentication the Switch Administration switch Open the Switch Administration window as - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 278
Open the Switch Administration window as described on page 41. 2. Click the Security Policies tab. 3. Click Authentication on the Security Policies menu. 4. Click the Shared Secret Keys subtab. 5. Click Add. FIGURE 129 Add Shared Secret Keys window 246 Web Tools Administrator's Guide 53-1001343 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 279
select a switch. 7. In secret key pairs by switch. 1. Open the Switch Administration window as described switch logs in to a fabric. 1. Open the Switch menu. 4. Use the Switch Policy Authentication Mode selector agent in the switch. The configuration Switch Administration window as described on page 41 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 280
Use the following procedure to change the systemGroup configuration parameters. 1. Open the Switch Administration window as described on page 41. 2. Click the SNMP tab ( authentication traps to be sent to the reception IP address. 5. Click Apply. 248 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 281
IP address. 5. Click Apply. Setting SNMPv3 configuration parameters Use the following procedure to set SNMPv3 configuration parameters. 1. Open the Switch IP address in the SNMPv3 section and type a new IP IP address in the Access Control List section and type a new host IP IP address in either IPv4 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 282
and Read Write. 5. Click Apply. NOTE The port number is not included. RADIUS service management Fabric OS supports RADIUS authentication, authorization, and accounting service (AAA). When configured for RADIUS, the switch becomes a Network Access Server (NAS) that acts as a RADIUS client. In this - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 283
Login Failed, or Switch Database when RADIUS Login Timeout from the Secondary AAA Service menu. To disable RADIUS service, select Switch Database from the Primary AAA Service menu and select None from the Secondary AAA Service menu. 5. Click Apply. Web Tools Administrator's Guide 251 53-1001343 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 284
management Configuring the RADIUS Service The configuration is chassis-based, so it applies to all logical switches (domains) on the switch and it is replicated on a standby CP, if one is present. It is saved in a configuration upload, and can be applied to other switches in a configuration download - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 285
service For adding a new Active Directory server, you must provide the server IP Switch Administration window as described on page 41. 2. Click the AAA Service tab. 3. To enable Active Directory service, select Active Directory from the Primary AAA Service menu. Web Tools Administrator's Guide - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 286
Directory service that is already configured. 1. Open the Switch Administration window as described on page 41. 2. Click the AAA Service tab. not deleted until you apply the changes from the AAA Services tab. 5. Click Apply in the AAA Services tab. A confirmation dialog box displays, warning you that - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 287
services for IP networks. Several protocols are available for providing authentication and secure transmission of data. From Web Tools, you can establish IPSec policies for FCIP implementations on 7800 extension switches with the upgrade license, the 7500 extension switches and FR4-18i blades - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 288
is transparent to the actual endpoints within the IP header in the original packet. Figure 133 provides a basic visual comparison of how transport mode and tunnel mode modify an IP datagram. FIGURE 133 Transport mode and tunnel mode comparison 256 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 289
to an IP datagram to algorithm calculation. The MAC is transmitted in an IP datagram. The same hash algorithm is then used and also provides privacy by encrypting the IP datagram. The use of an ESP header value, the authentication value is sent in an IP datagram, and the same hash algorithm is - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 290
a gateway to gateway configuration. A tunnel endpoint represents a set of IP addresses associated with actual endpoints that use the tunnel. IPSec is transparent VPN) for connecting a roaming computer, like a service laptop, to a protected network. 258 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 291
an IP connection, and to determine security policies for IP traffic over the connection. The initiating node proposes a policy based on the bit key each time. No encryption is performed. Advanced Encryption Standard (AES) 128 bit block cipher. RFC 4869 Advanced Encryption Standard (AES) 256 bit - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 292
groups Diffie-Hellman (DH) groups are used to determine the length of the base prime numbers for the Diffie-Hellman exchange. Diffie-Hellman key exchange is a cryptographic more secure key exchange by providing more bits (768, 1024, 2048, 8192). 260 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 293
the originator also is confirmed because the public key can decrypt only data that has been encrypted with the corresponding private key. Web Tools Administrator's Guide 261 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 294
FCIP 7500 extension switches and FR4-81i blades use FCIP protocol to IP to carry Fibre Channel traffic over IP networks. IPSec can be used to secure the IP flows over an displayed. The default view shows the IKE tab. FIGURE 136 IKE Policies (FCIP) 262 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 295
The Policy Number selector allows you to choose a number between 1 and 32. 4. Choose the Encryption Algorithm used in this policy. The choices -XCBC. 6. Turn Perfect Forward Secrecy on or off. The default is On. Perfect Forward Secrecy (PFS) provides additional security by Guide 263 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 296
IPSEC. 4. Assign a policy number. The Policy Number selector allows you to choose a number between 1 and 32. 5. Choose the Encryption Algorithm used in this policy. The choices are 3DES, AES-128, and AES_256. only to IKE policies. 7. Click OK. 264 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 297
IPSec can be applied to the management port on a switch or a CP blade to establish a secure connection between a PC or workstation that allows you to apply a Transform policy to a specific IP flow. Accessing the Ethernet IPSec Policies dialog box Use the following 's Guide 265 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 298
140 Add IKE Policy for management port 2. Type an IKE Policy Name. 3. Type the IP address of the authentication partner in Peer IP Address. 4. Type the switch's local identifier in the Local Identifier field. This is normally the IP address in IPv4 or IPv6 format, but it may also be a DNS name. 266 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 299
IPSec over management ports 17 5. Type the identifier of the remote peer switch in Peer Identifier. This is normally the IP address in IPv4 or IPv6 format, but it may also be a DNS name. 6. is displayed (Figure 141). FIGURE 141 Add SA dialog box Web Tools Administrator's Guide 267 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 300
An SPI (Security Parameter Index) number is automatically assigned, but may be manually overridden. 9. Click OK. Creating an SA proposal An SA proposal is sent . • The Diffie-Hellman group number. • The IKE SA lifetime. • The IP addresses of the endpoints. • The IPSec protocol (AH or ESP). • The - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 301
is reached first. 6. Click OK. Adding an IPSec transform policy The IPSec transform policy is the combination of protocols and algorithms applied to a flow of IP packets. IPSec unidirectional, and policies need to be applied to both inbound and outbound flows. Web Tools Administrator - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 302
a name in the Transform Name field. 4. Choose the IPSec Mode. The choices are Transport or Tunnel. 5. Select the SA Proposal name. 270 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 303
be created before adding a transform policy. If there are no names to choose from, you must create an IKE policy. 8. Optionally, enter a local and peer IP address. 9. Click OK. Web Tools Administrator's Guide 271 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 304
-directional. Selectors are associated with a specific source IP address, a specific peer IP address, and a specific transform. 1. Select the Selectors tab. The Selectors screen is displayed (Figure 145). FIGURE 145 Selectors tab 2. Select Add. 272 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 305
are unidirectional, and must be applied separately to inbound and outbound flows. 5. Type the IP address of the sender in the Source IP Address field. 6. Type the IP address of the receiver in the Peer IP Address field. 7. Choose the Transform Name. 8. The Protocol Name selector allows you to choose - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 306
field. The SPI must be manually applied when manually adding an SA. 4. Enter the IP address of the endpoint that sends the SA in the Source IP Address field. 5. Enter the IP address of the endpoint that receives flow from source to peer choose out. 274 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 307
tunnel IP address. 16. Click OK. Editing an IKE or IPSec policy An existing IKE or IPSec policy can be edited. 1. Open the Switch Administration can delete one or more IKE or IPSec policies. 1. Open the Switch Administration window. 2. Select Show Advanced Mode. 3. Select the Security Policies - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 308
following. 1. Open the Switch Administration window. 2. Select Show FCAP, DHCHAP, or both. 6. Choose the Switch Authentication Policy Mode. The choices are Passive, Active 0 (no DH authentication), 1 (1024 bit), 2 (1280 bit), 3 (1536 bit), or 4 (2048 bit). 9. Use the Device Authentication Policy Mode - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 309
12. Select Add. The Add Shared Secret Keys dialog box is displayed. 13. Browse to select the switch WWN or name and domain ID, or type the switch WWN or name and domain ID in the Switch WWN: Name/Domain ID field. 14. Generate shared secrets. Several tools and methods are available for - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 310
15. Enter the shared secret for the peer device (an HBA in this case) in the Peer Shared Secret and Confirm Peer Shared Secret fields. 16. Enter the shared secret for switch in the Local Shared Secret and Confirm Local Shared Secret fields. 17. Click Add. An entry is added in the - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 311
implemented by Fabric OS. A Brocade switch or director that supports CUP can be controlled by one or more host-based management programs or director consoles, such as Brocade Web Tools or Brocade Fabric Manager. (Refer to the Fabric Manager Administrator's Guide for information about Fabric Manager - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 312
switch is to enforce traffic between the FICON director and the host-based management program. Enabling port-based routing Port-based path selection is a routing policy in which paths are chosen based -based routing policy enabled. Port-based routing is a per-switch routing policy. After port-based - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 313
is disabled on a director, you cannot configure CUP attributes. 1. Click a FICON CUP-capable switch from the Fabric Tree. 2. Open the Switch Administration window as described on page 41. 3. Click Show Advanced Mode. 4. Click the FICON CUP tab. Web Tools Administrator's Guide 281 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 314
director console, Alternate Managers). You can configure FMS parameters for a switch only after FMS mode is enabled on the switch. All FMS parameter settings are persistent across switch power switch restart or power cycle, the switch reads the IPL file and actives its contents as default - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 315
to set the switch timestamp clock through the director console. When it is enabled, the director console (Web Tools, in this case) displays warning indications when the switch timestamp is changed Host Programming: (EBCDIC) USA/Canada -- 00037 Web Tools Administrator's Guide 283 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 316
to identify if the device allegiance is stuck. The Web Tools Switch Administration window displays the control device state and last update time You can click Refresh to get most recent update. You can manually reset allegiance to bring the control device back to the neutral Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 317
has a vector specifying its Prohibit attribute with respect to each of the other ports in the switch. This attribute is always set symmetrically in that a pair of ports is either prohibited or a new configuration or edit an existing configuration: Web Tools Administrator's Guide 285 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 318
and port names on the selected switch (similar to the dialog box shown of the selected configuration from the switch in a table format (Figure Port. This has no effect for Fabric OS based fabrics". 6. Review your changes. A blue switch. • Click Cancel to cancel all changes without saving - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 319
Configuration When you activate a saved CUP port connectivity configuration on the switch, the preceding configuration (currently activated) is overwritten. 1. Open the CUP Click a saved configuration or the active configuration from the list. Web Tools Administrator's Guide 287 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 320
CUP Port Connectivity Configuration confirmation dialog box displays. 4. Click Yes to delete the selected configuration; click No to cancel the deletion. 288 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 321
and FICON channel paths. RNID information for the switch displays in the Switch Information tab (Figure 153). FIGURE 153 Switch RNID Information RNID information for attached FICON devices and • Manufacturer • Manufacturer Plant • Unit Type • Tag Web Tools Administrator's Guide 289 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 322
18 Displaying Request Node Identification Data (RNID) 290 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 323
292 •Switch Administration panel tab for FC0E 293 •Port Administration panel tabs for FCoE 295 •FC0E configuration tasks 297 •Quality of Service (QoS disabling LLDP 324 •Enabling and disabling QoS priority-based flow control 324 •Enabling and disabling FCoE ports 324 Web Tools Administrator - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 324
19 FCoE overview FCoE overview A new view has been added for the Brocade 8000 switch and FCOE10-24 DCX blade, and new tabs have been added to the Switch Administration panel and the Port Administration panel to support FCoE interfaces and trunks. Port information that is unique to FCoE The General - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 325
Administration panel tab for FC0E 19 Switch Administration panel tab for FC0E The CEE tab on the Switch Administration panel (Figure 154) is specific to DCE/CEE configuration and management. FIGURE 154 Switch Administration panel with CEE tab Web Tools Administrator's Guide 293 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 326
panel tab for FC0E The CEE tab The CEE tab (Figure 155) has five tabs that are used for FCoE switch administration: • Link Aggregation tab • VLAN tab • FCoE Login tab • QoS tab • LLDP-DCBX tab . FIGURE 155 Switch Administration CEE tab 294 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 327
tabs specific to FCoE interfaces: • CEE Interfaces tab (Figure 156) • FCoE Ports tab (Figure 157) FIGURE 156 Port Administration CEE Interfaces tab Web Tools Administrator's Guide 295 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 328
19 Port Administration panel tabs for FCoE FIGURE 157 Port Administration FCoE Ports tab 296 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 329
configuration. The following lists the high level tasks in a suggested order: • Quality of Service (QoS) configuration (optional) - If you intend to implement a specific QoS scheme to prioritize configurations. It can be done as a separate task. Web Tools Administrator's Guide 297 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 330
map a specific class of traffic to a specific Class of Service (CoS). Adding a CEE map A CEE map defines priority and priority group tables that support Enhanced Transmission Selection (ETS). ETS allows bandwidth to be allocated based on priority settings through an exchange of priority group tables - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 331
Quality of Service (QoS) configuration 19 4. Select Add. box is displayed, the default values shown in the Priority Group Map match the IEEE 802.1Q recommendation for systems supporting eight traffic classes. The to the Priority Group table. Web Tools Administrator's Guide 299 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 332
19 Quality of Service (QoS) configuration An entry is added to the Priority Group table (Figure be mapped to traffic classes using a traffic class map. 1. Select the CEE tab on the Switch Administration panel. 2. Select the QoS tab. 3. Select the Traffic Class Map tab. 4. Select Add. - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 333
Quality of Service (QoS) configuration 19 The Traffic Class Map Configuration dialog box is displayed (Figure 161). This dialog box has the same structure as the Priority Group Map in the CEE Configuration dialog box (Figure 160). The default CoS-to-traffic class structure is based on IEEE 802.1Q - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 334
the global level enables you to apply changes to every port. 1. Select the CEE tab on the Switch Administration panel. 2. Select the LLDP-DCBX tab. 3. Select the Global tab (Figure 162). FIGURE , add a description in the System Description field. 302 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 335
default is 8. 11. Choose the parameters you want to exchange. Note that the term TLV indicates packaging of parameters into a Brocade-specific Type/Length/Value (TLV): - Advertise Optional-tlv - Advertises the following optional TLVs: • system-description - Describes switch or blade characteristics - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 336
19 LLDP-DCBX configuration 3. Select the LLDP Profile tab (Figure 163). FIGURE 163 CEE tab > LLDP-DCBX tab > LLDP Profile tab 4. Click Add. The LLDP Configuration dialog box is displayed (Figure 164). FIGURE 164 LLDP dialog box 304 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 337
For Mode, the choices are Tx (transmit), Rx, (receive) or Both. The default is Both. 8. In the Hello field, enter a time value in seconds. The Brocade-specific Type/Length/Value (TLV). - Advertise Optional-tlv - Advertises the following optional TLVs: • system-description - Describes switch or blade - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 338
, this tab is pre-selected. FIGURE 165 Port General tab 4. Select Edit Configuration. The CEE Edit Configuration dialog box is displayed. 306 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 339
that indicates the desired user priority. Each bit represents a user priority that is associated with FCoE traffic. The range is 0-255. The default is 8. 10. Assign a default class of service in the Default CoS field. The default CoS range is 0-7. The default is 0. 11. Click OK. 12. Click Enable - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 340
create a LAG. The LAG is treated as a single interface. 1. Select the CEE Interfaces tab on the Switch Administration panel. 2. Select the Link Aggregation tab (Figure 167). FIGURE 167 CEE tab > Link Aggregation tab of None can be a LAG Member. 308 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 341
switch will wait to receive LACP data units from its partner system and then respond. Passive is the default behavior. 5. Select the Type. Type refers to the type of trunking used by the LAG. The choices are Standard and Brocade Down. Web Tools Administrator's Guide 309 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 342
the VLAN configuration procedure, you need to know which interfaces or LAGs you want to associate with each VLAN. 1. Select the CEE tab on the Switch Administration panel. 2. Select the VLAN tab (Figure 169). FIGURE 169 CEE tab > VLAN tab 3. Click Add. 310 Web Tools Administrator - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 343
The format is VLAN. In this Fabric OS release, no bridge instances are supported, so the bridge number is always 0, and the value under Bridge is statically defined as box is selected by default. Click OK to enable FCoE. Clear the check box to disable FCoE. Web Tools Administrator - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 344
19 Configuring FCoE login groups Configuring FCoE login groups FCoE login groups control which FCoE switches are allowed to log in to a fabric. 1. Select the CEE tab on the Switch Administration panel. 2. Select the FCoE Login tab (Figure 171). FIGURE 171 CEE tab > FCoE Login tab 3. Click New. 312 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 345
If you choose Allow All Members, all devices attached to FCoE ports are allowed to log in to the switch. • If you choose Allow Specific Member, you can control which devices can log in, using Member Type, the entry and click Remove. 7. Click OK. Web Tools Administrator's Guide 313 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 346
panel. 1. Select the FCoE Ports tab on the Port Administration panel (Figure 173). The initial view shows a summary of all FCoE ports on the switch. FIGURE 173 FCoE Ports tab, Port Administration panel 2. To view information for a specific port, select the trunk in the FC0E Ports Explorer or select - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 347
Ports, General tab The Connected Devices tab shows information about devices connected to the switch (Figure 175). Six columns of information are displayed: • Device WWN shows the the FCoE port MAC address. • Switch Port shows the switch port WWN. Web Tools Administrator's Guide 315 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 348
, Connected Devices tab Displaying LAG information Use the following procedure to display LAG information. 1. Select the CEE tab on the Switch Administration panel. 2. Select the Link Aggregation tab LAG information is displayed (Figure 176). FIGURE 176 LAG information 316 Web Tools Administrator - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 349
1. Select the CEE tab on the Switch Administration panel. 2. Select the VLAN tab information. 1. Select the CEE tab on the Switch Administration panel. 2. Select the FCoE Login tab. display QoS information. 1. Select the CEE tab on the Switch Administration panel. 2. Select the QoS tab. From the QoS - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 350
Class Map Information Displaying LLDP-DCBX information Use the following procedure to display LLDP-DCBX information. 1. Select the CEE tab on the Switch Administration panel. 2. Select the LLDP-DCBX tab. - To display global settings, select the Global tab (Figure 181). 318 Web Tools Administrator - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 351
. 2. Under the CEE Interface Explorer, select a port. 3. Select the Port Statistics tab. Figure 183 shows the Port Statistics tab in Basic Mode. Web Tools Administrator's Guide 319 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 352
information, select Show Advanced Mode. An Advanced tab and an Error Detail tab are added next to Basic Mode (Figure 184). 320 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 353
Displaying CEE interface statistics 19 FIGURE 184 CEE Interface, Port Statistics, Advanced Mode The Advanced tab shows CEE transmission statistics (Figure 185). Web Tools Administrator's Guide 321 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 354
19 Displaying CEE interface statistics FIGURE 185 CEE Advanced Performance Statistics The Error Details tab shows transmission error statistics (Figure 186). FIGURE 186 CEE Error Detail Statistics 322 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 355
click menu on the Switch View, or from the Port Administration panel. To enable or disable a CEE interface from the Switch View, perform the following enable or disable a LAG, perform the following steps. 1. From the Switch Administration panel, select the CEE tab. 2. Select the Link Aggregation tab. - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 356
select Enable or Disable. Enabling and disabling QoS priority-based flow control Priority-based flow control (PFC) can be used to control PFC, perform the following steps. 1. Select the CEE tab on the Switch Administration panel. 2. Select the QoS tab. 3. Select the CEE Maps tab Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 357
Enabling and disabling FCoE ports 19 You can also enable or disable by selecting Edit Configuration, and selecting Enable or Disable on the FCoE Edit Configuration dialog box (Figure 187). FIGURE 187 FCoE Edit Configuration dialog box Web Tools Administrator's Guide 325 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 358
19 Enabling and disabling FCoE ports 326 Web Tools Administrator's Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 359
and switch platforms. TABLE 23 Web Tools limitations Area Details Blade Failure Browser Browser Browser Browser If a blade fails on the switch, the to use it. Launching the default Telnet is not supported in Windows Vista and Windows 2008 server. Fabric Watch, Switch Admin, HA, Name Server, - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 360
power-on self-test (POST) is disabled. If POST is enabled, the loss of network connectivity can exceed 5 minutes. Brocade switch after downgrading the firmware switch. Due to the nature of an HTTP connection, Web Tools will report this error after a 90-second default Web Tools supports only one - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 361
: There is no workaround. For Brocade 48000 directors, while monitoring the performance, if one or all the blades turn Faulty or if they are powered off or on, then the behavior of various monitoring graphs is as follows: The Switch Aggregate and Blade Aggregate graphs will freeze without any - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 362
Switch Administration page. Clicking the Refresh button will not fix the problem. Workaround: Click the Switch tab and the Switch Switch View, such as Status, Fan Temp, Power, and Beacon. Workaround: Verify Ethernet connection to the switch by pinging the logical switch IP Guide 53-1001343-01 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 363
monitoring graphs, 124, 125 BB credit, 50 beaconing, enabling, 63, 64 best practices for zoning, 154 blades, enabling and disabling, 45 browsers limitations, 327, 330 refresh frequency, setting, 5 supported, 4 buffer-limited ports, 199 C Challenge Handshake Authentication Protocol. Refer to - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 364
CUP port connectivity, 285 default heap size, 8 email SCSI command graphs, 129 SCSI vs. IP traffic graphs, 129 SID-DID performance blades, 45 dynamic load sharing, 226 Fabric Watch threshold alarms, 193 FICON Management Server mode, 281 ports, 105, 106 RADIUS service, 251 RLS probing, 52 switch - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 365
trace dump transfer, 157 beaconing, 63, 64 blades, 45 DLS, 226 Fabric Watch threshold alarms, 193 FICON Management Server mode, 281 insistent domain ID mode, 50 iSCSI Target Gateway service, 208 ports, 105 Ports on Demand, 107 RADIUS service, 251 RLS probing, 52 switch, 47 trunking mode, 114 zone - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 366
242 create, 240 deactivate, 242 delete, 242 distribute, 242 moving switch position, 242 feature licenses, 52 FICON Management Server mode, enabling and disabling, 281 parameters, 282 filtering events, 59 Filtering IP Addresses, 44 firmware download, 75 FRU alarms, configuring, 194 FSPF routing, 226 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 367
troubleshooting accessibility, 223 PDU, 205 search for FC target, 214 supported switches firmware download, 328 HTTP, 328, 329 Microsoft Windows Operating System, 330 Performance Monitor, 329 Switch View, 330 limited switch license, 10 link cost, 228 logging out, 16 , 124 Switch Administration window - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 368
, 106 platforms, supported, 4 polling rates , configuring, 101 port-based routing, 225 ports buffer enabling, 107 power supply status, 16 rebooting the switch, 48 IP traffic graph, 129 searching zone member selection lists, 153 sequence level switching, 50 session management, 17 sessions, ending, 16 - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 369
, 41 Switch Events and Switch Information, 32 switch events, displaying, 58 Switch Explorer, Admin Domains, 25 switch name, changing, 47 switch report, 48 switch status report, 161 Switch View, 28 Switch View buttons, 28 syslog IP address configuring, 43 removing, 44 system services, configuring - HP StorageWorks 4/64 | Brocade Web Tools Administrator's Guide v6.3.0 (53-100134 - Page 370
146 description, 144 LSAN, 172 modifying, 144 removing WWNs, 152 renaming, 145 replacing WWNs, 153 selecting a view, 141 zoning all access, 137 default zoning, 137 no access, 137 zoning database clearing, 154 maximum size, 140, 149 zoning views, 141 zoning, disabling, 150 zoning, saving changes, 88
53-1001343-01
28 July 2009
®
Web Tools
Administrator’s Guide
Supporting Fabric OS v6.3.0