HP StorageWorks 4/64 HP StorageWorks Fabric OS 5.3.0b Release Notes (AA-RWEYF- - Page 17
Fabric OS 5.3.0 fixes, Table 3 Fabric OS 5.3.0 closed defects
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Fabric OS 5.3.0 fixes Table 3 lists defects closed in the Fabric OS 5.3.0 firmware release. Table 3 Fabric OS 5.3.0 closed defects Closed defect summary Solution 4/256 Director running FICON with fsmode enabled & DLS on and port based route policy panics after upgrade from Fabric OS 5.0.x to Fixed per Fabric OS 5.3.0 5.1.x or 5.2.0. Kernel Ops error when counter is overrun during stress to fail test. Fixed per Fabric OS 5.3.0 Exception error on 4/256 can occur when performing port mirroring causing reboot. Fixed per Fabric OS 5.3.0 Tstimezone command doesn't show correct time and date if configdownload interface is used to update timezone. Fixed per Fabric OS 5.3.0 After executing trunk disable/enable on all edge switches in large scalability fabric, a 2/128 E_port became stuck in Loopback mode. Fixed per Fabric OS 5.3.0 Admin Domains enforcement on SID/DID not performed. Portmirror allowed addition of mirror port in Admin Domain3 when SID and DID were not port members. Fixed per Fabric OS 5.3.0 New active CP got Oops and reboot during initialization after hafailover command issued. Fixed per Fabric OS 5.3.0 After CP reboot, VE tunnel doesn't come up due to GE0 port on FR4-18i stuck in No_Sync state when using copper SFP's. Fixed per Fabric OS 5.3.0 Switch doesn't generate RSCN following zoning changes using cfgEnable in interop mode, resulting in no PLOGI from hosts, and no target discovery. Fixed per Fabric OS 5.3.0 When more than the supported number of Ex_Ports attached to same edge fabric with FCR switches, switch may panic causing continuous Fixed per Fabric OS 5.3.0 rebooting. When more than the supported number of intelligent blades (FR4-18i, FC4-16IP, etc) configured in 4/256, powering up the 4th and 5th Fixed per Fabric OS 5.3.0 blades at the same time results in a failover. In rare occurrence, FR4-18i Blade could become faulty after firmware download and slotpoweron followed by slotpoweroff. Fixed per Fabric OS 5.3.0 Tape backup job failures occasionally observed in congested IO conditions due to tape pipelining not properly handling target recovery. Fixed per Fabric OS 5.3.0 After changing FID & enabling FCR switch, all connected/active ports remain disabled. Fixed per Fabric OS 5.3.0 If active CP fails over after FC4-16ip port Blade runs slotpower on, all the FC4-16ip iSCSI ports can get stuck at "No_Sync" while FC Fixed per Fabric OS 5.3.0 ports come online. After an all switches disable on 4/256 with FC4-48 port blades, standby CP asserted and rebooted. Fixed per Fabric OS 5.3.0 HAfailover during FCIP IO through IPSec enabled tunnel sometimes causes VE port to go down, then come back up. Fixed per Fabric OS 5.3.0 User was able to configure isns client via isnsccfg to communicate with isns server through a port on FR4-18i, but this will not work (nor Fixed per Fabric OS 5.3.0 should it). HP StorageWorks Fabric OS 5.3.0b release notes 17