HP StorageWorks 4/8 Brocade Fabric OS MIB Reference (53-1000241-01, November 2 - Page 119
Table 4-3, Platform, Blades, Power Supply, WWN Card, it will be directly
View all HP StorageWorks 4/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 119 highlights
entPhysicalTable 1.3.6.1.2.1.47.1.1.1 4 This object is implemented for Fabric OS v4.1 and above. The "overall" physical entry for Brocade is the chassis, and in Fabric OS v4.4 and above it is marked as a FRU. Table 4-3 entPhysicalTable Entries for SilkWorm Switches Platform Blades Fans Power Supply WWN Card SilkWorm 200E 1 3 fans not a FRU 1 PS not a FRU 1 WWN unit not a FRU SilkWorm 3016 1 NA NA 1 WWN unit not a FRU SilkWorm 3250 1 3 fans not a FRU 1 PS not a FRU 1 WWN unit not a FRU SilkWorm 3850 1 4 fans not a FRU 2 PS not a FRU 1 WWN unit not a FRU SilkWorm 3900 1 6 fans in 3 FRUs 2 PS 1 WWN unit not a FRU SilkWorm 4012 NA NA NA NA SilkWorm 4100 1 3 FRUs 2 PS 1 WWN unit not a FRU SilkWorm 4900 1 3 FRUs 2 PS 1 WWN unit not a FRU SilkWorm 7500 1 3 FRUs 2 PS 1 WWN unit not a FRU SilkWorm 12000 / 24000 10 blades 3 fans 4 PS 2 WWN units in 1 FRU SilkWorm 48000 10 blades 3 fans 4 PS 2 WWN units in 1 FRU Chassis: one entry Container: one entry for each FRU slot Power supply if the PS is not a FRU, it will be directly below the chassis Module if the Module is not a FRU, it will be directly below the chassis Fan If the Fan is not a FRU, it will be directly below the chassis Figure 4-8 entPhysicalTable Containment Hierarchy (entPhysicalContainsTable) Fabric OS MIB Reference 4-7 Publication Number: 53-1000241-01