x17d, 0x17e, 0x17f, 0x18a, 0x18b, 0x18c, 0x18d, 0x18e, 0x18f

Page 19 highlights

Event Number (dec/hex) Event Name Predictive Maintenance Implication Suspected Components Description Logged? Mfg Fail? 381/0x17d 382/0x17e 383/0x17f 384/0x180 385/0x181 386/0x182 387/0x183 388/0x184 389/0x185 390/0x186 391/0x187 392/0x188 393/0x189 394/0x18a 395/0x18b 396/0x18c 397/0x18d 398/0x18e 399/0x18f 400/0x190 401/0x191 402/0x192 403/0x193 404/0x194 is ErrEnR2. The tenth byte is ErrDR2. LCC Installed Y Ignore - Operator LCC, Back End N This error code indicates the system state change Activity FC Port, consisting of an LCC hot plug insertion. The device Controller number of the drive added appears in this change record. A device number consisting of the controller serial number followed by a 0 indicates that the device number has not yet been assigned. LCC Removed Y Ignore unless no LCC, Back End N This error code indicates the system state change Operator activity FC Port, consisting of an LCC hot plug removal. The device Controller number of the lcc removed appears in this change record. A device number consisting of the controller serial number followed by a 0 indicates that the device number has not yet been assigned. DDM failed image disks Y Ignore unless no disk drives N This error code indicates the system could find a Operator activity usable image disk to reload NVRAM from at system start up. Battery charger firmware Y battery charger N This event is used to report status related to the downloader status battery charger firmware download process. See the extended event info field for the actual status. Failure in TWSI Driver module Y Controller, Y 2C_DRIVER_FAILURE This error indicates that an battery, power attempt to communicate with a two-wire serial supply, device has failed, possibly after multiple retries. midplane VSC7130 chip failed Y VSC7130 Y The VSC7130 chip used for FC signal detect and Signal Detect / port-bypass control has suffered a hardware failure. Port Bypass There is a VSC7130 for the host port and one for the Control chip JBOD port. This will result in the controller being failed. See extended information for which 7130 failed. Internal drive inserted Y Disk internal to N An internal disk has been inserted into the the controller enclosure. enclosure Internal drive removed Y Disk internal to N An internal disk has been removed from the the controller enclosure. enclosure Internal drive requesting port Y Disk internal to N An internal disk is requested that its FC port be bypass the controller bypassed. enclosure Internal drive has stopped Y Disk internal to N An internal disk has stopped requesting that its FC requesting port bypass the controller port be bypassed. enclosure Internal drive is indicating a Y Disk internal to N An internal disk is indicating that it is faulted. fault the controller enclosure Internal drive is no longer Y Disk internal to N An internal disk is no longer indicating that it is indicating a fault the controller faulted. enclosure No GBIC Installed Y GBIC port N No GBIC is installed on this controller GBIC of type MOD DEF 4 Y GBIC port N A GBIC has been inserted on this controller Installed GBIC of type Mod Def 4 Y GBIC port N A GBIC has been removed from this controller Removed GBIC Transmit Fault Y GBIC port N The GBIC is indicating a transmit fault GBIC no longer indicating Y GBIC port N The GBIC is no longer indicating a transmit fault Transmit Fault GBIC Receive Signal Lost Y GBIC port N The GBIC is indicating that the no receive signal is present GBIC no longer indicating Y GBIC port N The GBIC is no longer indicating that the no receive Receive Signal Lost signal is present Non-Mod Def 4 GBIC Y GBIC port Y A non-Module Definition 4 type GBIC has been Installed installed. This GBIC type is not supported and will be disabled. This GBIC will also be marked as failed. Non-Mod Def 4 GBIC Y GBIC port N A non-Module Definition 4 type GBIC has been Removed installed. This GBIC type is not supported but will be used anyway. GBIC EEPROM has failed Y GBIC Y Unable to communicate with the EEPROM on the GBIC. The EEPROM must be failed. JBOD FC Signal Detected Y JBOD Port N An FC signal is now detected on the JBOD port. JBOD FC Signal Lost Y JBOD Port N An FC signal is no longer detected on the JBOD

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

Event
Number
(dec/hex)
Event
Name
Logged?
Predictive
Maintenance
Implication
Suspected
Components
Mfg Fail?
Description
is ErrEnR2. The tenth byte is ErrDR2.
381/0x17d
LCC Installed
Y
Ignore - Operator
Activity
LCC, Back End
FC Port,
Controller
N
This error code indicates the system state change
consisting of an LCC hot plug insertion. The device
number of the drive added appears in this change
record.
A device number consisting of the
controller serial number followed by a 0 indicates
that the device number has not yet been assigned.
382/0x17e
LCC Removed
Y
Ignore unless no
Operator activity
LCC, Back End
FC Port,
Controller
N
This error code indicates the system state change
consisting of an LCC hot plug removal.
The device
number of the lcc removed appears in this change
record.
A device number consisting of the
controller serial number followed by a 0 indicates
that the device number has not yet been assigned.
383/0x17f
DDM failed image disks
Y
Ignore unless no
Operator activity
disk drives
N
This error code indicates the system could find a
usable image disk to reload NVRAM from at system
start up.
384/0x180
Battery charger firmware
downloader status
Y
battery charger
N
This event is used to report status related to the
battery charger firmware download process.
See the
extended event info field for the actual status.
385/0x181
Failure in TWSI Driver module
Y
Controller,
battery, power
supply,
midplane
Y
2C_DRIVER_FAILURE This error indicates that an
attempt to communicate with a two-wire serial
device has failed, possibly after multiple retries.
386/0x182
VSC7130 chip failed
Y
VSC7130
Signal Detect /
Port Bypass
Control chip
Y
The VSC7130 chip used for FC signal detect and
port-bypass control has suffered a hardware failure.
There is a VSC7130 for the host port and one for the
JBOD port.
This will result in the controller being
failed.
See extended information for which 7130
failed.
387/0x183
Internal drive inserted
Y
Disk internal to
the controller
enclosure
N
An internal disk has been inserted into the
enclosure.
388/0x184
Internal drive removed
Y
Disk internal to
the controller
enclosure
N
An internal disk has been removed from the
enclosure.
389/0x185
Internal drive requesting port
bypass
Y
Disk internal to
the controller
enclosure
N
An internal disk is requested that its FC port be
bypassed.
390/0x186
Internal drive has stopped
requesting port bypass
Y
Disk internal to
the controller
enclosure
N
An internal disk has stopped requesting that its FC
port be bypassed.
391/0x187
Internal drive is indicating a
fault
Y
Disk internal to
the controller
enclosure
N
An internal disk is indicating that it is faulted.
392/0x188
Internal drive is no longer
indicating a fault
Y
Disk internal to
the controller
enclosure
N
An internal disk is no longer indicating that it is
faulted.
393/0x189
No GBIC Installed
Y
GBIC port
N
No GBIC is installed on this controller
394/0x18a
GBIC of type MOD DEF 4
Installed
Y
GBIC port
N
A GBIC has been inserted on this controller
395/0x18b
GBIC of type Mod Def 4
Removed
Y
GBIC port
N
A GBIC has been removed from this controller
396/0x18c
GBIC Transmit Fault
Y
GBIC port
N
The GBIC is indicating a transmit fault
397/0x18d
GBIC no longer indicating
Transmit Fault
Y
GBIC port
N
The GBIC is no longer indicating a transmit fault
398/0x18e
GBIC Receive Signal Lost
Y
GBIC port
N
The GBIC is indicating that the no receive signal is
present
399/0x18f
GBIC no longer indicating
Receive Signal Lost
Y
GBIC port
N
The GBIC is no longer indicating that the no receive
signal is present
400/0x190
Non-Mod Def 4 GBIC
Installed
Y
GBIC port
Y
A non-Module Definition 4 type GBIC has been
installed.
This GBIC type is not supported and will
be disabled.
This GBIC will also be marked as
failed.
401/0x191
Non-Mod Def 4 GBIC
Removed
Y
GBIC port
N
A non-Module Definition 4 type GBIC has been
installed.
This GBIC type is not supported but will
be used anyway.
402/0x192
GBIC EEPROM has failed
Y
GBIC
Y
Unable to communicate with the EEPROM on the
GBIC.
The EEPROM must be failed.
403/0x193
JBOD FC Signal Detected
Y
JBOD Port
N
An FC signal is now detected on the JBOD port.
404/0x194
JBOD FC Signal Lost
Y
JBOD Port
N
An FC signal is no longer detected on the JBOD