HP StorageWorks 8/20q HP StorageWorks 8/20q Fibre Channel Switch installation - Page 43

con d with System Type set

Page 43 highlights

The following example configures SNMP trap 1: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> set setup snmp trap 1 A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so. Current Values: Trap1Enabled Trap1Address Trap1Port Trap1Severity Trap1Version Trap1Community False 10.0.0.254 162 warning 2 public New Value (press ENTER to not specify value, 'q' to quit): Trap1Enabled (True / False) :True Trap1Address (hostname, IPv4, or IPv6 Address) :10.20.30.40 Trap1Port (decimal value, 1-65535) : Trap1Severity (select a severity level) 1=unknown 6=warning 2=emergency 7=notify 3=alert 8=info 4=critical 9=debug 5=error 10=mark :4 Trap1Version (1 / 2) :1 Trap1Community (string, max=32 chars) :OSEMcommunity Do you want to save and activate this snmp setup? (y/n): [n] For more information about CLI commands, see the HP StorageWorks 8/20q Fibre Channel Switch command line interface guide. 4. Configure the switches in OSEM by adding each 8/20q Fibre Channel Switch as a Managed System configured with System Type set to FC Switch and the IP address for the switch. For detailed instructions, see the OSEM documentation available at the web sites listed in "Installation instructions and documentation for SIM, RSP, OSEM, and ISEE" on page 41. 8/20q Fibre Channel Switch installation and reference guide 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

8/20q Fibre Channel Switch installation and reference guide
43
The following example configures SNMP trap 1:
8/20q FC Switch #> admin start
8/20q FC Switch (admin) #> set setup snmp trap 1
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Current Values:
Trap1Enabled
False
Trap1Address
10.0.0.254
Trap1Port
162
Trap1Severity
warning
Trap1Version
2
Trap1Community
public
New Value (press ENTER to not specify value, 'q' to quit):
Trap1Enabled
(True / False)
:True
Trap1Address
(hostname, IPv4, or IPv6 Address) :10.20.30.40
Trap1Port
(decimal value, 1-65535)
:
Trap1Severity
(select a severity level)
1=unknown
6=warning
2=emergency
7=notify
3=alert
8=info
4=critical
9=debug
5=error
10=mark
:4
Trap1Version
(1 / 2)
:1
Trap1Community (string, max=32 chars)
:OSEMcommunity
Do you want to save and activate this snmp setup? (y/n): [n]
For more information about CLI commands, see the
HP StorageWorks 8/20q Fibre Channel Switch
command line interface guide
.
4.
Configure the switches in OSEM by adding each 8/20q Fibre Channel Switch as a Managed System
configured with System Type set to
FC Switch
and the IP address for the switch. For detailed instructions,
see the OSEM documentation available at the web sites listed in ”
Installation instructions and
documentation for SIM, RSP, OSEM, and ISEE
” on page 41.