After FCIP tunnels are created, the configuration is saved in a persistent database. At this point,
![]() |
View all HP StorageWorks 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 485 highlights
is configured, and can be displayed by entering the portShow fciptunnel all command: switch0:admin> portshow fciptunnel ge0 all Port: ge0 Tunnel ID 0 Tunnel Description Not Configured Remote IP Addr 10.10.12.100 Local IP Addr 10.62.0.100 Remote WWN Not Configured Local WWN 10:00:00:05:1e:38:58:61 Compression on Fastwrite on Tape Pipelining on Committed Rate 1000000 Kbps (1.000000 Gbps) SACK on Min Retransmit Time 100 Keepalive Timeout 90 Max Retransmissions 9 VC QoS Mapping on DSCP Marking (Control): 45, DSCP Marking (Data): 30 VLAN Tagging Not Configured TCP Byte Streaming off Status : Inactive Connected Count: 0 IKE Policy 1 IPSec Policy 1 Pre-Shared Key qbcdefghijklmnopqrstuvwxyz123456 After FCIP tunnels are created, the configuration is saved in a persistent database. At this point, all configured FCIP tunnels now appear in the fabric as VE_Ports. Fabric OS 6.2 administrator guide 481